Manual.ly Logo

Chieftec MRT-6320P Manual

0.0 · 0 Ratings

PDF manual · 18 Pages

English

M: OA-GPT-5-NAN
page

/ 18

Loading...
79178755afeb489536975eee5368d4cf4976 page 3
1.1 INTRODUCTION
First of all, thank you for purchasing MRT/MRW Series – PS/2 size Mini
Redundant power supply. The MRT/MRW Series are 1+1, Hot
swappable/Hot-pluggable/Redundant power supply set, it consists of:
(1) Complete metal frame (nickel-plated)
(2) Compact size (real PSII form factor) 1+1 power modules
(3) Backplane board
The MRT/MRW Series of hot swappable redundant power supply offer
maximum 300/320/400 watts of output power. The MRT/MRW series provide
Active Power Factor correction (PFC) at full range AC Input that complies with
IEC 1000-3-2 for CE norms. The units are compact size as PS/2 form factor and
all the power modules are built interior 40X40X20 mm /40X40X28 mm ball
bearing DC fans for better ventilation. Each power module has been designed
with +3.3V, +5V, +12V, -12V, -5V & 5VSB circuits. All you can see on the
backplane board are passive components and this is the key point of greater
MTBF.
The units also provide a warning sub-system, including LED display, buzzer
alarm, TTL signal etc.. At the same time, it also indicates the status of the power
system and DC fans.
2

Chat with your Chieftec MRT-6320P manual using AI

Get instant AI answers from your Chieftec MRT-6320P manual

Ask anything about the Chieftec MRT-6320P. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend MRT-6320P?

Yes No

Frequently Asked Questions

A

The MRT-6320P is part of the MRT series offering a 320W per-module rating in a 1+1 redundant configuration, providing up to dual-module capacity for redundancy. Combined maximum output depends on model pairing and load distribution but is designed for 320W modules in this configuration.

Is this answer helpful?

A

Yes. The unit is hot-swappable and hot-pluggable: defective modules can be turned off and removed while the parallel module continues to power the system. Follow safety steps: disable the module switch, loosen thumb screws, wear heat-resistant gloves and allow the removed module to cool before handling.

Is this answer helpful?

A

The MRT series includes overload, over-voltage and over-current protections, EMI filtering meeting FCC/CISPR Class B, and safety certifications such as UL 1950, CSA 22.2 and TUV IEC 950. It also features active PFC to meet IEC-1000-3-2 Class D requirements.

Is this answer helpful?

A

After installation power on and verify green LEDs for both modules. Remove one module following the hot-swap procedure; the system should remain powered while external warning LED turns red and the buzzer sounds. Reinsert the module to restore normal status and silence alarms.

Is this answer helpful?

A

Input range is 90–264 VAC at 47–63 Hz. Hold-up time is specified at a minimum of 16 ms at full load with 90 VAC input. Inrush currents are listed (e.g., 60–80A depending on voltage) per module.

Is this answer helpful?

A

Alarms and status use front/rear LEDs, an audible buzzer and TTL signal outputs. There are connectors for individual power LEDs, total system LED, buzzer reset and TTL power-good/reset signals for integration with chassis indicators or monitoring cards.

Is this answer helpful?

A

Yes. Confirm correct pinouts and keyed connectors before powering up, secure mounting screws, test redundancy and alarms before closing the chassis, and observe hot-swap warnings about hot surfaces and handling to avoid burns or system shutdowns.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Hot-swappable 1+1 redundant design for continuous uptime
  • Full-range AC input (90–264 VAC) with Active PFC to meet IEC standards
  • Compact PS/2 form factor fits space-constrained server chassis
  • Multiple protections (OVP/OCP/OLP), EMI filtering and international safety certifications
  • Audible and visual fault alarms plus TTL signaling for monitoring integration
VS

Disadvantages

  • Typical efficiency ~63% at full load, lower than modern high-efficiency supplies
  • Relatively small cooling fans may be noisy or have limited airflow in some installations
  • Older multi-rail ATX-style outputs may be less convenient than single-rail modern designs
  • Manual hot-swap requires care (hot surfaces) and physical access to module screws
  • Total combined rail limits require planning to avoid exceeding per-rail or combined power caps
M: OA-GPT-5-NAN

Product Specification

Fan

4x 1.57in

Cable management

fixed

Connectors

1x 20/24-Pin, 1x 4-Pin ATX12V, 2x SATA, 8x IDE, 2x Floppy

Dimensions (WxHxD)

5.91x3.43x7.28in

+3.3V

18A

+5V

25A

+12V

15A

-12V

0.5A

+5Vsb

2A

Number of 12V rails

1

PFC

active

Form factor

rackmount

Specification

Server power supply

Special features

redundant

Color

gray

M: OA-GPT-54-NAN

Product Description

Chieftec MRT-6320P 320W, Server power supply Manual

The Chieftec MRT-6320P 320W is a compact, PS/2-sized redundant server power solution designed for reliability in critical systems. Built as a 1+1 hot-swappable redundant set, the MRT series integrates two power modules in a passive-backplane frame, offering balanced load sharing, active PFC and multiple safety and alarm features for continuous operation. Each module delivers stable multi-rail outputs including +3.3V, +5V, +12V, -12V, -5V and +5VSB, cooled by twin 40 mm ball-bearing fans to maintain thermal stability in dense server environments.

The MRT-6320P supports a full AC input range (90–264 VAC) and includes Active Power Factor Correction to meet IEC-1000-3-2 standards. With protections for overload, over-voltage and over-current plus EMI filtering to FCC/CISPR Class B and certified safety ratings (UL, CSA, TUV/IEC), it’s engineered for enterprise deployments. Onboard fault signaling—LEDs, buzzer and TTL alerts—help technicians quickly spot and respond to issues without interrupting system uptime. The design emphasizes modularity: individual modules contain all circuitry while the passive backplane improves mean time between failures (MTBF).

Installation is straightforward: mount the unit in an appropriate chassis, connect keyed cables to the motherboard and peripherals, and verify pinouts carefully. The unit supports remote on/off control and remote sensing for stable voltages under varying loads. During maintenance, the hot-swap procedure allows safe removal and replacement of a defective module while a healthy module continues supplying power; audible and visual alarms notify operators when a module is offline. Hold-up time, inrush limits and detailed output current specs for each rail ensure predictable behavior under real-world loads.

Operational highlights include balanced parallel load sharing, compact PS/2 form factor, low noise through EMI filtering, and redundancy signaling for integration into monitoring systems. The MRT-6320P targets servers and systems where space is limited but high availability is essential—blade servers, small rack systems, and industrial controllers.

Notes

  • Ensure correct connector pinouts and secure connections before powering up.
  • Observe hot-swap safety: disable module switch, wear heat-resistant gloves and allow removed modules to cool.
  • Test redundancy and alarm functions after installation to confirm proper behavior.
M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly