Chieftec MRT-6320P Manual
PDF manual · 18 Pages
English

Quick check
Incorrect answer, please try again.
Chat with your Chieftec MRT-6320P manual using AI
Get instant AI answers from your Chieftec MRT-6320P manual
Ask anything about the Chieftec MRT-6320P. Answers come from this manual, with the pages they are based on.
Ask a Question
Do you recommend MRT-6320P?
Yes NoFrequently Asked Questions
The MRT-6320P is part of the MRT series offering a 320W per-module rating in a 1+1 redundant configuration, providing up to dual-module capacity for redundancy. Combined maximum output depends on model pairing and load distribution but is designed for 320W modules in this configuration.
Is this answer helpful?
Yes. The unit is hot-swappable and hot-pluggable: defective modules can be turned off and removed while the parallel module continues to power the system. Follow safety steps: disable the module switch, loosen thumb screws, wear heat-resistant gloves and allow the removed module to cool before handling.
Is this answer helpful?
The MRT series includes overload, over-voltage and over-current protections, EMI filtering meeting FCC/CISPR Class B, and safety certifications such as UL 1950, CSA 22.2 and TUV IEC 950. It also features active PFC to meet IEC-1000-3-2 Class D requirements.
Is this answer helpful?
After installation power on and verify green LEDs for both modules. Remove one module following the hot-swap procedure; the system should remain powered while external warning LED turns red and the buzzer sounds. Reinsert the module to restore normal status and silence alarms.
Is this answer helpful?
Input range is 90–264 VAC at 47–63 Hz. Hold-up time is specified at a minimum of 16 ms at full load with 90 VAC input. Inrush currents are listed (e.g., 60–80A depending on voltage) per module.
Is this answer helpful?
Alarms and status use front/rear LEDs, an audible buzzer and TTL signal outputs. There are connectors for individual power LEDs, total system LED, buzzer reset and TTL power-good/reset signals for integration with chassis indicators or monitoring cards.
Is this answer helpful?
Yes. Confirm correct pinouts and keyed connectors before powering up, secure mounting screws, test redundancy and alarms before closing the chassis, and observe hot-swap warnings about hot surfaces and handling to avoid burns or system shutdowns.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Hot-swappable 1+1 redundant design for continuous uptime
- Full-range AC input (90–264 VAC) with Active PFC to meet IEC standards
- Compact PS/2 form factor fits space-constrained server chassis
- Multiple protections (OVP/OCP/OLP), EMI filtering and international safety certifications
- Audible and visual fault alarms plus TTL signaling for monitoring integration
Disadvantages
- Typical efficiency ~63% at full load, lower than modern high-efficiency supplies
- Relatively small cooling fans may be noisy or have limited airflow in some installations
- Older multi-rail ATX-style outputs may be less convenient than single-rail modern designs
- Manual hot-swap requires care (hot surfaces) and physical access to module screws
- Total combined rail limits require planning to avoid exceeding per-rail or combined power caps
Product Specification
Fan
4x 1.57in
Cable management
fixed
Connectors
1x 20/24-Pin, 1x 4-Pin ATX12V, 2x SATA, 8x IDE, 2x Floppy
Dimensions (WxHxD)
5.91x3.43x7.28in
+3.3V
18A
+5V
25A
+12V
15A
-12V
0.5A
+5Vsb
2A
Number of 12V rails
1
PFC
active
Form factor
rackmount
Specification
Server power supply
Special features
redundant
Color
gray
Product Description
Chieftec MRT-6320P 320W, Server power supply Manual
The Chieftec MRT-6320P 320W is a compact, PS/2-sized redundant server power solution designed for reliability in critical systems. Built as a 1+1 hot-swappable redundant set, the MRT series integrates two power modules in a passive-backplane frame, offering balanced load sharing, active PFC and multiple safety and alarm features for continuous operation. Each module delivers stable multi-rail outputs including +3.3V, +5V, +12V, -12V, -5V and +5VSB, cooled by twin 40 mm ball-bearing fans to maintain thermal stability in dense server environments.
The MRT-6320P supports a full AC input range (90–264 VAC) and includes Active Power Factor Correction to meet IEC-1000-3-2 standards. With protections for overload, over-voltage and over-current plus EMI filtering to FCC/CISPR Class B and certified safety ratings (UL, CSA, TUV/IEC), it’s engineered for enterprise deployments. Onboard fault signaling—LEDs, buzzer and TTL alerts—help technicians quickly spot and respond to issues without interrupting system uptime. The design emphasizes modularity: individual modules contain all circuitry while the passive backplane improves mean time between failures (MTBF).
Installation is straightforward: mount the unit in an appropriate chassis, connect keyed cables to the motherboard and peripherals, and verify pinouts carefully. The unit supports remote on/off control and remote sensing for stable voltages under varying loads. During maintenance, the hot-swap procedure allows safe removal and replacement of a defective module while a healthy module continues supplying power; audible and visual alarms notify operators when a module is offline. Hold-up time, inrush limits and detailed output current specs for each rail ensure predictable behavior under real-world loads.
Operational highlights include balanced parallel load sharing, compact PS/2 form factor, low noise through EMI filtering, and redundancy signaling for integration into monitoring systems. The MRT-6320P targets servers and systems where space is limited but high availability is essential—blade servers, small rack systems, and industrial controllers.
Notes
- Ensure correct connector pinouts and secure connections before powering up.
- Observe hot-swap safety: disable module switch, wear heat-resistant gloves and allow removed modules to cool.
- Test redundancy and alarm functions after installation to confirm proper behavior.
Search for 67,706 Manuals online