Boso Roid II Manual
PDF manual · 16 Pages
English

Quick check
Incorrect answer, please try again.
Chat with your Boso Roid II manual using AI
Get instant AI answers from your Boso Roid II manual
Ask anything about the Boso Roid II. Answers come from this manual, with the pages they are based on.
Roid II Maintenance Schedule
Have the device calibrated by the manufacturer or an authorized service to ensure accuracy and compliance.
Use only a soft, dry cloth to clean the main body of the blood pressure monitor. Avoid moisture.
Remove the rubber bag from the cuff. Wash the outer cover by hand at a maximum temperature of 30 degrees Celsius.
Wipe the device with mikrozid sensitiv liquid for at least 5 minutes. Use spray disinfection for the cuff.
Free maintenance reminders
Timed to your purchase date. Always free, unsubscribe anytime.
Ask a Question
Do you recommend Roid II?
Yes NoDo you recommend Roid II?
Yes NoFrequently Asked Questions
Do not inflate the cuff above 300 mmHg. Exceeding this limit can damage the device and pose safety risks to the patient.
Is this answer helpful?
Technical calibration testing must be performed at least every two years by the manufacturer or an authorized service provider.
Is this answer helpful?
For children aged 3 to 12, Phase IV (K4) is recommended. This is the point where sounds change from clear to muffled.
Is this answer helpful?
No. Only the cuff cover can be washed by hand at 30°C. Remove the rubber bladder first. Wipe the main unit with a dry cloth.
Is this answer helpful?
Bosch + Sohn provides a two-year factory warranty from the date of purchase, provided you have the original invoice.
Is this answer helpful?
Yes, the device is marked shock-protected, meaning it has been tested to function correctly after being dropped from up to one meter.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Complies with CE marking and ISO 81060-1 international standards for medical devices
- Shock-protected design tested to withstand drops from one meter without damage
- Adjustable air release valve allows precise control over deflation speed for accuracy
- Covers all Korotkoff phases (K4/K5) suitable for adults, children, and pregnant women
- Includes detailed multilingual instructions covering setup, usage, and maintenance
Disadvantages
- Requires manual auscultation skills and a separate stethoscope for operation
- Cuff bladder must be removed before washing, adding extra steps to cleaning
- Warranty does not extend to normal wear and tear items like the cuff itself
- Calibration testing is mandatory every two years to maintain regulatory compliance
- Strict temperature limits for storage and operation may restrict use in extreme environments
Product Specification
Operating Mode
No Battery
Measurement Type
Upper Arm
Cuff Circumference
8.66-12.60 in
Memory Function
No
Display
No
Product Description
Boso Roid II Blood Pressure Monitor: A Comprehensive Guide to Accurate Health Tracking
The Boso Roid II Blutdruckmessgerät represents a pinnacle of manual blood pressure measurement technology, designed for both clinical settings and dedicated home health monitoring. Manufactured by Bosch + Sohn GmbH, this device adheres to strict European medical regulations and the international ISO 81060-1 standard, ensuring reliability and precision in every reading. The kit includes the sphygmomanometer unit, an arm cuff suitable for various arm circumferences, a user manual, and an optional carrying case.
Understanding how to use the Boso Roid II Blutdruckmessgerät Manual is essential for obtaining accurate results. The device utilizes the auscultatory method, requiring the user to listen for Korotkoff sounds through a stethoscope. For adults, Phase V (K5) is recommended as the endpoint where sounds disappear, while children aged 3 to 12 should use Phase IV (K4), marking the change from clear to muffled sounds. Pregnant women typically follow the adult protocol unless specific audible noises require switching to Phase IV.
Proper usage involves significant preparation. Patients must sit comfortably with their back supported, legs uncrossed, and arms resting at heart level. Before the first measurement, a five-minute rest period is crucial to stabilize the body. During inflation, the cuff should be pumped above systolic pressure, but never exceeding 300 mmHg. The WHO recommends a deflation speed of 2 to 3 mmHg per second, adjustable via the valve screw on the device. After measurement, fully opening the release valve ensures rapid deflation.
Durability is a key feature of the Roid II, which is shock-protected and tested to withstand drops from one meter. Cleaning is straightforward; the unit requires only a dry soft cloth, while the cuff cover can be hand-washed at temperatures up to 30°C after removing the rubber bladder. Disinfection protocols are also clearly defined, recommending specific agents like Mikrozid Sensitiv Liquid for wiping surfaces. With a two-year warranty covering manufacturing defects, this monitor stands as a robust tool for maintaining cardiovascular health.