Manual.ly Logo

Beurer IH 24 Kids Manual

0.0 · 0 Ratings

PDF manual · 158 Pages

English

M: QW-35-FL
page

/ 158

Loading...
7c5b3cc0c6109b803902b6971fc61c50fc6d page 16
22
Important
•
Only use the nasal douche with isotonic saline
solutions.
•
Replace the nasal douche after a year.
The maximum volume of the nasal douche is 10 ml.
If you are unsure about the correct dilution of the
saline solution, please consult your pharmacist.
7.9 Using the nasal douche
To use the nasal douche correctly, proceed as fol-
lows
B
:
1.
Twist the cover
17
90° anticlockwise and re-
move it in an upward direction.
2. Also lift the collection container
18
out.
3. Fill the saline container
19
with saline solution.
4.
Place the collection container
18
into the saline
container
19
.
5. Place the cover
20
on the saline container
19
.
Twist the cover
20
in a clockwise direction until
it clicks firmly into place.
6. Connect the compressed air hose
7
to the sa-
line container
19
from below.
7.
Carefully position the cover
20
in one of your
nostrils. Breathe through your nose.
8. Press the On/O control
2
. To start the appli-
cation, place one finger over the cover hole
20
on the container.
Notice
During the application, breathe slowly and evenly
through your nose. Tilt your head slightly in the op
-
posite direction to the nostril being treated so that
the saline solution can flow deep into the nose.
9.
To pause or stop the application, take your finger
o the cover hole
20
on the saline container
19
.
10.
Once your nose feels clear again, you can
stop the application. The application should
be stopped at the latest once the maximum
filling quantity has been used.
7.10 Cleaning
See “Cleaning and maintenance”.
8. CHANGING THE FILTER
I
n normal operating conditions, the air filter must be
replaced after approx. 200 operating hours or one
year. Please check the air filter regularly (after 10-
12 nebulisation procedures). Replace the used filter
if it is very dirty or clogged. If the filter has become
damp, it must also be exchanged for a new filter.
Important
•
Do not attempt to clean the used filter and re-
use it.
•
Only use the manufacturer’s original filter, oth-
erwise your nebuliser may become damaged
and suciently eective treatment cannot be
guaranteed.
•
Do not repair or maintain the air filter while it
is in use.
•
Never operate the device without a filter.
To replace the filter, proceed as follows:
Important
•
First switch the device o and disconnect it
from the mains.
•
Allow the device to cool down.
1. Remove the filter cap
5
upwards.
C
Notice
If the filter remains in the device after the cap has
been removed, take the filter out of the device, e.g.
with tweezers or similar.
2. Re-insert the filter cap
5
with a new filter.
3. Ensure that it is securely in place.
9. CLEANING AND MAINTE-
NANCE
Atomiser and atomiser set
Warning
Adhere to the following hygiene instructions to
avoid health risks.
•
The atomiser
8
and the rest of the atomiser
set are intended for multiple use. Please note
that dierent areas of application involve dif
-
ferent requirements in terms of cleaning and
hygienic preparation.
Notice
•
Do not clean the atomiser or the atomiser set
mechanically using a brush or similar device,
as this could cause irreparable damage and it
will mean that the best treatment results can no
longer be guaranteed.
•
Please consult your doctor about the addition-
al requirements in terms of the hygienic prepa-
ration needed (hand care, handling of medica-

Chat with your Beurer IH 24 Kids manual using AI

Get instant AI answers from your Beurer IH 24 Kids manual

Ask anything about the Beurer IH 24 Kids. Answers come from this manual, with the pages they are based on.

IH 24 Kids Maintenance Schedule

Remind me when maintenance is due
Daily (after last use)
Disinfect the atomiser and set

Place disassembled atomiser, masks, mouthpiece, and nosepiece in boiling water for 5 minutes. Immerse hose in 2% NaOCl for 15 mins.

Show in the manual (page 23)
Yearly or every 200 hours
Replace air filter

Under normal conditions, replace the air filter after approximately 200 operating hours or one year.

Show in the manual (page 22)
Yearly
Replace atomiser and set

Replace the atomiser and rest of the set no later than one year (assuming max 360 disinfections) due to wear affecting therapy efficiency.

Show in the manual (page 24)
Yearly
Replace nasal douche

Replace the nasal douche accessory after one year of use.

Show in the manual (page 22)
After every treatment
Clean the atomiser and set parts

Wash all parts of the atomiser and used set with hot, non-boiling water immediately after each treatment to remove residues.

Show in the manual (page 23)
Every 10-12 uses
Check air filter condition

Inspect the air filter regularly after 10-12 nebulisation procedures. Replace if dirty, clogged, or damp.

Show in the manual (page 22)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend IH 24 Kids?

Yes No

Frequently Asked Questions

A

It is suitable for children from 6 months under supervision and self-use from 12 years. Adults can use it too.

Is this answer helpful?

A

It treats upper and lower respiratory diseases like asthma, bronchitis, and sinusitis via aerosol therapy.

Is this answer helpful?

A

Wash parts with hot water after use. Disinfect masks and cups in boiling water for 5 minutes.

Is this answer helpful?

A

No, essential oils are unsuitable and may clog the system or cause bronchospasms.

Is this answer helpful?

A

Replace the air filter after 200 hours of use or once a year, whichever comes first.

Is this answer helpful?

A

Yes, provided you follow the 30-minute on and 30-minute off cycle to prevent overheating.

Is this answer helpful?

A

Stop usage immediately and contact customer service or an authorized retailer for repairs or support.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Suitable for children aged 6 months and older with adult supervision.
  • Quiet operation at 52 dB minimizes disturbance during treatment sessions.
  • Includes a storage bag for organized travel and home use accessories.
  • Safety features include automatic thermal protection for motor health.
  • Designed specifically for domestic use with clear user guidance.
VS

Disadvantages

  • Requires a mandatory 30-minute rest period after 30 minutes of operation.
  • Filter component must be replaced annually or after 200 operating hours.
  • Not intended for professional clinical settings or hospital environments.
  • Cleaning process is mandatory after every single use session.
  • Essential oils are not compatible and may damage the system.
M: QW-35-FL

Product Specification

Type

Compressor

Operation Mode

Mains powered

Mist Output

0.01 fl oz/min

Features

Suitable for children, disinfectable, medicine containers

Package Contents

Bag, mouthpiece, childrens mask, baby mask, elbow piece, filter set, connecting hose

M: QW-35-FL

Product Description

Beurer IH 24 Kids Inhalator Review

Respiratory Health for Families

Managing breathing issues in children requires the right tools to ensure comfort and safety during daily care routines. The Beurer IH 24 Kids provides a reliable solution for home therapy within domestic environments. This compressor nebulizer helps treat upper and lower airway conditions effectively without invasive procedures. Parents often look for safety and ease of use in medical devices to manage respiratory health. This model meets those needs with specific design features for younger users who need gentle treatment. It targets conditions like asthma, bronchitis, and sinusitis commonly affecting young lungs. The aerosol therapy accelerates healing and prevents disease spread through medication delivery. By using prescribed medication, you minimize systemic diffusion and reduce risks elsewhere in the body. The device humidifies dry airways and loosens stubborn secretions for easier coughing. It helps relieve swelling and inflammation in the bronchial mucosa during flare-ups. Children breathe easier and sleep better during treatment sessions at home.

Operation and Safety Standards

Safety is paramount when treating kids at home with medical equipment. The device includes a 30-minute ON and 30-minute OFF cycle to prevent overheating the motor. It operates quietly at around 52 dB(A) to avoid disturbing sleeping children during nap time. Parents should always follow the Beurer IH 24 Kids Manual for proper setup and usage guidelines. The box contains a nebulizer cup, hose, mouthpiece, and silicone masks for different ages. A storage bag keeps accessories organized when traveling or moving between rooms. Cleaning is essential for hygiene to prevent bacterial growth on plastic parts. Parts must be washed with hot water after every single use cycle. Some components require disinfection in boiling water to kill germs effectively. Filters change annually or after 200 hours of actual use time. Do not use essential oils as they may clog the internal nozzle system. Consult your pharmacist regarding compatibility with silicone and PP materials found in the set.

Maintenance and Long Term Use

Keeping the device clean ensures consistent performance for every therapy session. Do not use abrasive cleaners or submerge the main electrical unit in water. Water damage can cause electrical faults and void safety certifications completely. Always unplug before cleaning the air hose or nebulizer components. The air filter protects the motor from dust entering the internal mechanism. Replace it if dirty or damp to ensure proper airflow. Do not repair the device yourself as this voids the warranty coverage. If issues arise, contact customer service or an authorized retailer for help. This product follows European medical device standards for safety and efficacy. It is not for professional clinical use in hospitals or clinics. Store it in a dry place away from children and pets. Always consult a doctor before starting therapy to confirm diagnosis. Proper usage ensures better health outcomes and faster recovery times. Regular disinfection prevents bacterial growth which could harm the patient. Use a 2 percent sodium hypochlorite solution for the hose tube. Ensure all parts dry completely before storage in the bag. Avoid direct sunlight on the storage bag to prevent plastic degradation.

M: QW-35-FL

© Copyright 2026 Manual.ly