9858b832732077ca58b96db8763c315df285 page 1
04/2022
6LE005209C
IR motion detector comfort 1.1 m
Order no.: 8534 12 ..
IR motion detector comfort 2.2 m
Order no.: 8534 22 ..
Operating and assembly
instructions
Berker GmbH & Co. KG
Zum Gunterstal
66440 Blieskastel, Germany
Tel.: + 49 6842 945 0
Fax: + 49 6842 945 4625
e-mail: info@berker.de
www.berker.com
z
IR motion detector comfort 1.1 m / 2.2 m
Safety instructions
Electrical equipment must only be installed and
assembled by a qualied electrician in accord-
ance with the relevant installation standards,
regulations, directives and safety and accident
prevention directives of the country.
Failure to comply with these installation instruc-
tions may result in damage to the device, re or
other hazards.
Due to its detection behaviour the device is not
suitable for use in burglary detection or alarm
systems.
These instructions are an integral component of
the product and must be retained by the end user.
Design and layout of the device
(3)
(5)
(6)
(4)
(2)
(1)
Fig. 1: Design and layout of the device
(1) Insert (see "Accessories", not in scope of
delivery)
(2) Frame (not included)
(3) cover
(4) Motion detector design cover
(5) Module retaining screw
(not for Berker R.1/R.3/R.8)
(6) Interface between insert/application module
Function
Correct use
- Automatic switching of lighting depending on heat
motion and ambient brightness
- Application module for switch insert, dimmer in-
sert or motion detector extension unit
- Only suitable for use in indoor areas with no drip
and no spray water.
Product characteristics
- Integrated button for selecting operating modes
and special functions
- Lockable integrated button
- Operating mode - automatic mode, permanent
ON, permanent OFF can be selected
- Display operating mode via LED
- Potentiometer for setting the response bright-
ness, delay time and detection sensitivity
- Delay time adjustable
- Pulse encoder mode for current pulse/stairwell
circuits
- Adjustable detection angle for adapting the de-
tection area
- Additional adjustment of the response brightness
via Teach-In function
- Party function
- Presence simulation
- Operation on motion detector extension units
- Optional extension unit operation via installation
button
- Commissioning optionally via IR remote control
for comfort motion detector (see accessories)
Automatic mode
The motion detector detects heat motion caused by
people, animals, or objects.
On switch insert:
- The light will be switched on for the delay time, if
movements are detected in the detection area
and the set brightness threshold is undershot.
Each detected movement restarts the delay time.
- The light will be switched o󰀨 if no additional
movements are detected in the detection area
and the set delay time has elapsed.
On dimmer insert:
- The light will be switched on to the switch-on
brightness level for the delay time if movements
are detected in the detection area and the set
brightness threshold is undershot. Each detected
movement restarts the delay time.
- After the delay time elapses the lighting will be
dimmed to 50% of the switch-on brightness-level
and will remain at this brightness level for 30 s
(switch-o󰀨 pre-warning). Any motion detected
during the switch-o󰀨 pre-warning restarts the de-
lay time and restores the switch-on brightness
level.
- The light will be switched o󰀨 if no motion is de-
tected any longer in the detection area and the
set delay time and the switch-o󰀨 time have
elapsed.
On extension unit
- If motion is detected in the detection area of the
extension unit, the extension unit insert sends a
pulse to the main unit and then locks for 10 sec-
onds. Recording takes place independently of the
brightness on the extension unit. If motion is still
detected after 10 seconds, a pulse is sent again.
- Upon receiving an extension unit pulse, the main
unit switches the light on for the delay time, if the
set brightness threshold is undershot. Every fur-
ther extension unit pulse restarts the delay time
of the main unit.
Performance after mains breakdown/return of
mains supply
- Mains breakdown shorter than 0.2 s:
The function is not impaired.
- Mains breakdown longer than 0.2 s:
There is no function during the mains breakdown.
The current conguration is saved in non-volatile
memory.
- Return of mains supply:
The application module executes an initialisation
for approx. 15 s, during which the lighting will be
switched on. Motion detection starts thereafter. If
no motion is detected during the rst 5 s, the
lighting is switched o󰀨. The saved conguration is
loaded from memory. During this period local op-
eration via the button or extension unit can be
used.
Operation
Operating concept
(8)
(7)
Fig. 2: Operation and display elements
(7) Button
(8) Status LED
Operation is executed by pushing the button (7) on
the motion detector:
- A short press of the button switches the operating
modes. The operating mode is displayed via the
status LED behind the optics cover of the motion
detector.
- Keeping the button pressed activates special
functions. Selection of the special functions is
supported by the LED display (Fig. 3).
Selecting the operating mode
Briey press the button repeatedly until the de-
sired operating mode is selected.
The status LED indicates the selected operating
mode (see Table 1).
Switching the operating mode nishes the party
function or presence simulation, if these functions
were previously active.
Disabling/enabling operating mode selection via
button
Keep the button pressed for more than 15
seconds, until the status LED is ashing green
(Fig. 3).
Selection of the operating mode via the button is
disabled.
or if the button is locked:
Keep the button pressed for more than 15
seconds, until the status LED is ashing green
(Fig. 3).
The operating mode can be selected via the
button again.
Switching on the lighting via push-button exten-
sion unit or changing the switch-on brightness
level (Table 2)
Optionally the lighting can be switched on via a
mechanical push-button extension unit.
For extension unit operation, the lighting is
switched on independently of the set brightness
threshold.
When using the dimmer inserts, the last set
brightness level will be saved as the switch-on
brightness-level.
Activating/interrupting party function
The party function switches the lighting on for 2
hours. During this time no extension unit commands
are executed.
In the case of motion detectors on extensions,
activating the party function causes cyclical trans-
mission of the switch-on pulse every 10 s. How-
ever, the light is only switched on when the
brightness threshold is undershot at the main
unit.
Keep the button pressed for more than 5 sec-
onds, until the status LED is ashing red (Fig. 3).
The lighting is switched on for 2 hours. During
this time the status LED is ashing red. Upon
elapse of 2 hours, the motion detector switches
to Autooperation mode.
Briey press the button.
The party function will be cancelled, the motion
detector returns to Auto operation mode.
Activating/deactivating
presence simulation
During operation, the motion detector counts the mo-
tion detections in one full hour and saves the result.
With active presence simulation at the beginning of
the hour with the most detections saved, the light
will be switched on for the duration of the delay time,
even no motion is detected.
During the presence simulation, presence detection
and extension unit commands will continue to be
executed normally.
The presence simulation cannot be activated via
the extension unit
Keep the button pressed for more than 20 sec-
onds, until the status LED is slowly ashing red
(gure 3).
The presence simulation is active. During this
time the status LED lights orange. The motion
detector switches the lighting on at the saved
time.
Briey press the button.
The presence simulation will be disabled, the
motion detector returns to Automode.
Settings
Setting response brightness via Teach-In func-
tion
The response brightness is the brightness value
saved in the motion detector; when this value is
undershot the motion detector switches the connect-
ed load if movements are detected. Via Teach-In
function the current ambient brightness is saved as
the response brightness.
Teach-In cannot be carried out on the extension
unit.
The load is switched o󰀨.
Keep the button pressed for more than 10
seconds, until the status LED is ashing orange
(Fig. 3).
The motion detector detects the current ambient
brightness and saves it as response brightness.
Setting of the response brightness via Teach-In
function and via the brightness potentiometer has
the same priority. Teach-In overwrites the re-
sponse brightness set on the brightness potenti-
ometer. If the setting is made again via the poten-
tiometer , the Teach-In gure will be overwritten.
Setting the load
If the switching performance is not satisfactory after
commissioning when using the motion detector on
universal switch inserts and universal touch dim-
mers, a load setting must be carried out.
A load setting is required each time the load is
changed.
Switch o󰀨 load.
Keep the button pressed for more than 25
seconds, until the status LED is slowly ashing
orange.
Release push-button.
The connected load blinks once. The device is in
selection mode.
If no further actions are performed within the next
10 seconds, the dimmer switches to normal oper-
ation.
Briey press the bottom button repeatedly to
activate the desired setting mode.
► See Table 3a / 3b
Information for electricians:
For the version labelling of the ush-mounted
insert, see packaging label or sticker on the back
of the housing.
Function Party function Teach-In Keylock Presence
simulation
Load setting
mode
1)
LED display
red
orange green red orange
Hold time
operation
button
> 5 s > 10 s > 15 s > 20 s > 25 s
1)
Only on universal switch insert and universal dimmer insert
Fig. 3: Selection of special functions and LED display
LED display Operating
mode
On switch or
dimmer insert
On extension unit insert
-- Auto Motion-dependent and brightness-
dependent switch on/switch o󰀨 of
the load
Motion-independent switching pulse
for the main unit
green Permanent
ON
Load is permanently switched-on/
switched-o󰀨.
Extension unit signals will not be
evaluated
Cyclical transmission of the switch-
on pulse every 10 s
red Permanent
OFF
--
Table 1: Display of operating modes
Dimming status Operation
button
Performance of the insert
Motion detector applied on switch insert
OFF Short press Load is switched on for the set delay time
ON Short press Extension of switch-on time by the set delay time
Motion detector applied on push-button dimmer comfort 1gang
OFF Short press Load is switched on to the switch-on brightness-level for the set delay
time
ON Short press Extension of switch-on time by the set delay time at the same
brightness
OFF Long press Load is switched on to switch-on brightness-level, subsequent dimming
in the opposite direction of the last dimming process. Thereafter the
load remains switched on for the delay time
ON Long press Changes the current brightness. Dimming takes place in the opposite
direction of the last dimming operation until maximum or minimum
brightness. Subsequently the load remains switched on at the set
brightness for the set delay time.
Table 2: Operation via push-button extension unit
Setting the load on a universal switch or dimmer insert from Version R1.2
Briey
press
the
button
Setting mode Duration and conrmation of the
load setting
The light to conrm the load ashes at
50% brightness.
Information for use
1 x Load
factory setting
Settings duration: approx. 30 sec.
Load switching/dimming phases may
occur during the automatic settings
process.
The load ashes one last time as a con-
rmation and then goes out. The device
returns to normal operation.
Factory setting with automatic
load recognition.
If the switching behaviour is
unsatisfactory after that, restart
selection mode and select the
best option.
2 x LED mode 1
(phase cut-on)
After approx. 5 sec., the load ashes
twice as a conrmation and then goes
out. The device returns to normal oper-
ation.
Recommended for lower 230 V
LED loads up to max. 60 W if the
switching/dimming behaviour is
unsatisfactory after automatic
load setting.
3 x LED mode 2
(phase cut-on)
Settings duration: ≤ 50 sec.
Load switching/dimming phases may
occur during the automatic settings
process.
Finally, the load ashes three times as
a conrmation and then goes out. The
device returns to normal operation.
Recommended for higher 230 V
LED loads from 50 W, which can
be operated in the phase cut-on.
Observe manufacturer's data!
4 x Fine setting of
minimum bright-
ness
5 predened minimum brightness levels
for 2.5 sec. each, run through repeated-
ly (3 runs).
As soon as the connected load
shows a satisfactory minimum bright-
ness, conrm by quickly pressing the
bottom button.
After approx. 5 sec., the load ashes
four times as a conrmation and re-
mains switched on (50% brightness).
The device returns to normal operation.
To optimise the switch-on behav-
iour, or if the load ickers in the
lower dimming range, the mini-
mum brightness setting can be
manually adjusted here.
Table 3a
Setting the load on a universal switch or dimmer insert up to Version R1.1
Briey
press the
button
Setting mode Conrmation of the
load setting
Information for use
1 x Load ne-setting Load blinks 1 x after approx.
30 s and changes to normal
operation
Not suitable for ohmic loads
(e.g. incandescent, HV halogen
lamps); use factory load setting.
If the load ne-setting does
not bring any improvement for
energy-saving lamps or 230 V
LED lamps, select the energy-
saving lamp ne-setting or 230 V
LED lamp universal setting.
2 x Factory load setting Load blinks 2 x after approx.
6 s and changes to normal
operation
3 x Energy-saving lamp
ne-setting in phase
cut-on
Load blinks 3 x after approx.
30 s and changes to normal
operation
Energy-saving lamps are
switched on at a brightness level
of at least 50% in order to ensure
an ignition process.
4 x 230 V LED lamp uni-
versal setting in phase
cut-on or phase cut-o󰀨
Load blinks 4 x after approx.
5 s and changes to normal
operation
For connected dimmable 230 V
LED lamps the dimming principle
and the optimal switch-on bright-
ness level is set automatically.
For all setting modes Load blinks 5 x The selected setting mode is not
supported by the insert.
Table 3b

Chat with your Berker Comfort 8534 12 manual using AI

Get instant AI answers from your Berker Comfort 8534 12 manual

Ask anything about the Berker Comfort 8534 12. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend Comfort 8534 12?

Yes No

Frequently Asked Questions

A

It offers three primary modes: automatic (motion- and brightness-dependent switching), permanent ON, and permanent OFF. Special functions include party mode (lights on for 2 hours), presence simulation, Teach-In brightness learning, and pulse encoder mode for stairwell circuits.

Is this answer helpful?

A

Yes. Besides on-device potentiometers and buttons, commissioning and configuration can be performed using an optional IR remote control (Hager EE806). Setting via IR requires placing the response brightness potentiometer in the T position; remote control locks and setting locks are supported.

Is this answer helpful?

A

Extension units send pulses to the main unit when they detect motion. The main unit then switches lighting if the stored brightness threshold is undershot. Extension units lock for 10 seconds after a pulse; repeated detections send further pulses to restart the main unit's delay time.

Is this answer helpful?

A

Adjustable settings include response brightness (approx. 5–150 Lux or independent/daylight), delay time (10s to 30min or pulse encoder mode), detection sensitivity (10–100%), and detection angle (independently adjustable left/right between 45° and 90° each). These control when and how long lighting responds to motion.

Is this answer helpful?

A

No. The detector has an IP20 rating for indoor, dry environments only. It must be protected from condensation and direct water exposure and is temperature-rated for typical indoor conditions (-5 to +45 °C).

Is this answer helpful?

A

Perform the load setting procedure available for universal switch or dimmer inserts. The device offers automatic and manual load modes (several LED and energy-saving lamp presets) and a fine minimum-brightness setting to optimize dimming and avoid flicker for specific loads.

Is this answer helpful?

A

Teach-In saves the current ambient brightness as the response brightness threshold. While in Teach-In, the detector measures ambient light and overwrites the potentiometer setting; later changes via the potentiometer will override the Teach-In value if needed.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Flexible commissioning: on-device potentiometers or optional IR remote for full configuration.
  • Advanced functions: Teach-In brightness, party mode, presence simulation, and pulse encoder mode.
  • Adjustable detection: sensitivity, delay time, and asymmetric detection angle (90–180° range).
  • Integration friendly: compatible with Berker switch/dimmer inserts and extension units for larger areas.
  • Memory and resilience: non-volatile memory stores settings and handles brief mains interruptions.
VS

Disadvantages

  • Professional installation required: must be installed by a qualified electrician.
  • Indoor only: IP20 rating means no use in wet or outdoor environments.
  • Not for alarm systems: detection behaviour unsuitable for burglary or security alarm use.
  • Potential false triggers: sensitive to heat sources, vibrations or nearby ventilation if poorly sited.
  • Load-specific setup: dimmable or LED loads may require manual load setting for optimal behaviour.
M: OA-GPT-5-NAN

Product Specification

Type

Motion detector

Sensors

Infrared

Alarm zones

1

Standard

N/A

Detection range

26.25-39.37 ft (Mounting height 3.61 ft)

Detection angle

90° to 180°

Operating temperature

23°F to +113°F

Dimensions

2.19x2.19x1.65in

Special features

Remote control (sold separately)

Protection class

IP20

M: OA-GPT-54-NAN

Product Description

Berker IR Motion Detector Comfort 1.1m Q.1/Q.3 — Quick Overview

The Berker IR Motion Detector Comfort 1.1m Q.1/Q.3 is a versatile indoor motion sensor designed to automate lighting based on heat motion and ambient brightness. Intended for professional installation, it integrates with Berker switch and dimmer inserts and supports extension units and optional IR remote commissioning. It offers adjustable detection angle, sensitivity, delay time, and response brightness, plus features such as party mode, presence simulation, Teach-In brightness learning, and pulse encoder mode for stairwell circuits.

Key features and how it works

Equipped with a status LED and an integrated button, the device supports three main operating modes: automatic, permanent ON, and permanent OFF. In automatic mode the sensor switches lights on when motion and low brightness are detected and switches them off after a programmable delay. With dimmer inserts it will restore a preset switch-on brightness and then warn before switching off by dimming to 50% for 30 seconds. Extension units can trigger the main unit via pulses and operate independently of ambient brightness.

Commissioning can be done directly using the on-device potentiometers for sensitivity, response brightness and delay time, or more comfortably using an optional IR remote control. The Teach-In function captures current ambient brightness as the switching threshold, while the detection angle can be limited on each side to avoid unwanted triggers. Pulse encoder mode offers compatibility with stairwell/current pulse circuits.

Practical applications

This motion detector is suited for corridors, stairwells and communal indoor areas where energy-efficient, presence-based lighting is required. Party mode forces lights on for two hours, and presence simulation reproduces typical usage patterns to deter intruders by switching lights at previously recorded busy times. The device stores settings in non-volatile memory and accommodates behaviour after brief mains interruptions.

Installation and commissioning notes

Only qualified electricians should fit the unit into compatible Berker inserts. Avoid mounting near heat sources, ventilation, or vibrating surfaces to reduce false triggers. Use test mode to verify detection coverage and adjust sensitivity or detection angle as needed. When integrating dimmable loads, follow the load-setting procedure to ensure clean switching and optimal dimming behavior. The device is IP20 rated and intended for indoor use within specified temperature and humidity ranges.

Final thoughts

The Berker IR Motion Detector Comfort 1.1m balances flexible configuration with advanced functions for reliable automated lighting control in indoor environments. Its combination of local controls, Teach-In, remote commissioning and extension unit compatibility makes it a strong option for stairwells, corridors and communal areas where efficiency and adaptive lighting are priorities.

Notes:

  • Designed for indoor, dry environments (IP20).
  • Not suitable for burglar alarm systems due to detection characteristics.
  • Settings and commissioning are reversible; many functions can be locked to prevent tampering.