Quick check
Incorrect answer, please try again.
Chat with your Benning IT 100 manual using AI
Get instant AI answers from your Benning IT 100 manual
Ask anything about the Benning IT 100. Answers come from this manual, with the pages they are based on.
Ask a Question
Do you recommend IT 100?
Yes NoFrequently Asked Questions
It measures AC and DC voltage, resistance, continuity, low resistance, insulation resistance, Polarisation Index, and Dielectric Absorption Ratio. This makes it suitable for electrical installation checks and insulation condition assessment.
Is this answer helpful?
The rotary switch provides 50 V, 100 V, 250 V, 500 V, and 1000 V insulation test settings. Choose the voltage appropriate for the equipment, circuit, and applicable test procedure.
Is this answer helpful?
At the 1000 V test setting, the tester measures insulation resistance up to 20 GOhm. Accuracy is specified differently at the highest range than within the main measurement range.
Is this answer helpful?
Yes. It provides a continuity test over a 600 Ohm range. Its integrated buzzer responds at resistance values below approximately 4 to 14 Ohm, with a response time under 100 ms.
Is this answer helpful?
PI and DAR compare insulation resistance values at timed intervals to help evaluate insulation quality. The tester calculates PI from the 10-minute and 1-minute values, and DAR from the 1-minute and 30-second values.
Is this answer helpful?
Voltage measurement is intended for circuits up to 600 V AC or DC within CAT IV 600 V limits. Resistance, low-resistance, insulation, PI, and DAR measurements require a voltage-free measuring point.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Combines voltage, resistance, continuity, low-resistance, insulation, PI, and DAR testing in one instrument.
- Supports selectable insulation test voltages from 50 V to 1000 V and measures up to 20 GOhm.
- CAT IV 600 V rating, protective holster, high-voltage warning LED, and approved safety leads support safer field work.
- Automatic ranging, backlit display, lead zeroing, and lockable testing improve everyday usability.
- Includes leads, probes, alligator clips, pouch, batteries, and an integrated high-breaking-capacity fuse.
Disadvantages
- Designed for qualified electricians and trained personnel rather than casual household use.
- For safe operation, resistance and insulation measuring points must be verified de-energized first.
- The LOCK function can prevent detection of inadmissible external voltage during active testing.
- IP30 protection means it is for dry indoor environments and has no water protection.
- Annual professional calibration is recommended to maintain the stated measurement accuracy.
Product Description
Benning IT 100 Insulation Tester - Read, Download & Print Free
The Benning IT 100 Insulation Tester is a professional electrical test instrument designed for electricians and trained technical personnel who need dependable insulation, resistance, and voltage measurements. Built for work in dry indoor environments, it supports testing on circuits up to 600 V AC or DC and carries a CAT IV 600 V rating to earth. Its durable protective rubber holster, fold-out stand, illuminated display, and clear control layout make it a practical choice for routine inspections and fault finding.
Versatile electrical testing functions
This compact tester combines several important diagnostic functions in one device. It measures AC and DC voltage, standard resistance, continuity, and low resistance. For insulation work, selectable test voltages of 50 V, 100 V, 250 V, 500 V, and 1000 V help users assess cable, equipment, and installation insulation across a broad range of applications.
Insulation resistance measurement reaches up to 20 GOhm at the 1000 V setting. The device also calculates the Polarisation Index (PI) and Dielectric Absorption Ratio (DAR), supporting deeper evaluation of insulation condition over time. A PI above 2 or a DAR above 1.3 is identified as characteristic of excellent insulation quality.
Designed for clear and controlled operation
The large digital LCD presents measured values, test voltage, polarity, battery status, and active functions. Automatic range selection simplifies use, while the backlight improves readability in dim work areas. A red high-voltage indicator and display warning provide added awareness when hazardous voltage is detected.
The TEST button starts low-resistance and insulation tests, while the LOCK feature can hold a test active when longer measurements are required. The blue function key switches between AC and DC voltage, resistance and continuity, or low-resistance testing and lead compensation. The PI DAR key selects advanced insulation analysis modes.
Safety and maintenance considerations
The Benning IT 100 is intended for qualified users who understand electrical hazards and relevant safety procedures. Insulation testing produces potentially dangerous test voltages, so circuits must be verified as de-energized before connecting leads for resistance-related measurements. Users should wait for the displayed test voltage to return to 0 V before disconnecting after insulation tests.
The supplied package includes safety leads, probes, alligator clips, a protective pouch, four AA batteries, and an integrated fuse. Regular fuse checks are required before low-resistance and insulation tests, and annual calibration helps maintain stated accuracy.
Notes
- Use approved safety leads and protective caps for CAT III and CAT IV work.
- Replace depleted batteries or a defective fuse promptly.
- Clean only with a dry cloth; avoid solvents and abrasive products.
- Do not use the tester in wet or potentially explosive environments.