It measures AC and DC voltage, AC and DC current, resistance, capacitance, frequency, continuity, and diodes. It also provides non-contact phase detection and external conductor testing functions.
Is this answer helpful?
The meter measures voltage up to 600 V AC or DC and current up to 400 A AC or DC. It is rated for CAT III 600 V to earth and CAT IV 300 V to earth when used within the stated safety requirements.
Is this answer helpful?
Yes. TRUE RMS measurement is used for AC functions, improving measurement performance with many non-sinusoidal electrical signals. Accuracy can vary with waveform crest factor and operating conditions.
Is this answer helpful?
LoZ Auto-V automatically selects AC or DC voltage measurement and the appropriate range. Its low input impedance helps reduce misleading capacitive or inductive ghost-voltage readings.
Is this answer helpful?
Yes. Select the DC current function, perform the zero balance away from live conductors, and clamp around one conductor centrally. Do not place more than one conductor inside the clamp for current measurement.
Is this answer helpful?
The continuity function uses an audible buzzer. It sounds when the measured resistance falls below approximately 20 to 200 ohms. The circuit should be de-energized before testing.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- TRUE RMS measurement supports practical readings on distorted AC waveforms.
- Measures AC/DC voltage to 600 V and AC/DC current to 400 A.
- Includes resistance, continuity, diode, capacitance, and frequency functions.
- LoZ Auto-V, HOLD, MIN/MAX, DC zero, and low-pass filtering improve field usability.
- Compact 225 g design includes test leads, pouch, and AAA batteries.
Disadvantages
- Clamp opening is limited to 27 mm, which may not fit larger conductors.
- Low-pass filter accuracy is specified only from 15 to 60 Hz.
- The IP30 housing has no stated water protection.
- Voltage indicator must not be used to confirm absence of voltage.
- Annual calibration is recommended to preserve specified measurement accuracy.
Product Specification
Measurement range
max. 300 A, max. 600 V, max. 40 mOhm
Package contents
Case, test leads, battery
Product Description
Benning CM 2-1 Current Clamp Multimeter - Read, Download & Print Free
The Benning CM 2-1 Current Clamp Multimeter is a compact TRUE RMS measuring tool designed for qualified electricians and trained electrical personnel. It combines dependable clamp-current measurement with essential multimeter functions, making it suitable for installation checks, troubleshooting, maintenance, and general electrical testing. Its clear controls and automatic measuring-range selection help users work efficiently across a wide variety of applications.
Versatile electrical measurements
This clamp meter measures AC and DC voltage up to 600 V, plus AC and DC current up to 400 A. The clamp design allows current to be measured around a single live conductor without disconnecting the circuit, supporting faster and less intrusive diagnostics. TRUE RMS technology improves measurement usefulness when working with non-sinusoidal signals commonly found in modern electrical systems.
Beyond voltage and current, the CM 2-1 measures resistance, capacitance, and frequency. It also includes continuity and diode testing functions for checking wiring paths, connections, and electronic components. The frequency range extends to 50 kHz, while capacitance measurement reaches 10 mF, giving technicians practical coverage for many routine service tasks.
Practical controls and display features
A 4-digit LCD provides readings up to 4,000 counts, with automatic polarity indication and a warning symbol for potentially hazardous contact voltages. The display illumination activates automatically in low-light conditions, helping improve visibility in panels, plant rooms, and other dim work areas. Battery status is also shown clearly, making it easier to plan replacements before work is interrupted.
Useful measurement aids include HOLD, MIN/MAX recording, DC zero balancing, and a low-pass filter for AC measurements. The low-pass filter can reduce interference from high-frequency pulses, such as those associated with pulsed motor drives. The LoZ Auto-V function automatically identifies AC or DC voltage and uses low input impedance to help suppress ghost voltages.
Built for professional field work
The Benning CM 2-1 has a maximum clamp opening of 27 mm and a compact 188 x 56 x 28 mm housing. It weighs approximately 225 g with batteries installed, so it is convenient to carry in a tool bag. Supplied accessories include red and black safety test leads, a protective pouch, and two AAA batteries. Optional accessories, including flexible current transformers and specialist test-lead sets, can broaden its usefulness.
Note: Observe applicable safety procedures, use approved leads, and stay within CAT III 600 V or CAT IV 300 V limits. The voltage indicator is not intended to prove absence of voltage. Annual calibration is recommended to maintain stated accuracy.