BENNING CM 10–PV
Operating Manual
BENNING CM 10-PV
TRUE RMS digital current clamp Multimeter for
- DC/ AC voltage measurements
- DC/ AC current measurements
- resistance measurements
- continuity and diode tests
- capacity measurement
- frequency measurement
- temperature measurement
Table of contents
1. User instructions
2. Safety instructions
3. Scope of delivery
4. Device description
5. General information
5.1 General information
5.2 Data logger functions
5.2.1 Setting the data logger
5.2.2 Automatic storage (LOG)
5.2.3 Manual storage (SAVE)
5.3 Data transmission to the smartphone/ tablet
6. Ambient conditions
7. Electrical specifications
8. Measuring with the BENNING CM 10-PV
9. Maintenance
10. Technical data of measuring accessories
11. Environmental note
1. User instructions
This operating manual is intended for
- skilled electricians and
- electrotechnically trained personnel.
The BENNING CM 10-PV is intended for measurements under dry ambient con-
ditions. It must not be used in electrical circuits with a nominal voltage higher
than 1000 VAC/DC (see section 6 „Ambient conditions“ for details). When using
the BENNING TA PV measuring adapter, the nominal voltage range increases to
1500 VAC/ 2000 VDC (see section 8.2.2 „Voltage measurement (switch position
PV)“ and section 10 „Technical data of measuring accessories“ for details).
The following symbols are used in this operating manual and on the BENNING
CM 10-PV:
Application around and removal from HAZARDOUS LIVE conductors
is permitted.
Warning of electrical danger!
Indicates instructions which must be followed to avoid danger to per-
sons.
Attention! Must comply with documentation!
This symbol indicates that the information provided in the operating
man ual must be complied with in order to avoid risks.
CAT II
Measuring category II is applicable to testing and measuring circuits
which are directly connected to user connections (sockets and similar
connections) of the low-voltage mains installation.
CAT III
Measuring category III is applicable to testing and measuring circuits
connected to the distribution circuit of the low-voltage mains installation
of a building.
CAT IV
Measuring category IV is applicable to testing and measuring circuits
connected to the feed-in point of the low-voltage mains installation of
a building.
This symbol on the BENNING CM 10-PV indicates that the BENNING
CM 10-PV is equipped with protective insulation (protection class II).

Chat with your Benning CM 10-PV manual using AI

Get instant AI answers from your Benning CM 10-PV manual

Ask anything about the Benning CM 10-PV. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend CM 10-PV?

Yes No

Frequently Asked Questions

A

Without accessories, the meter handles up to 1000 V AC/DC. With the BENNING TA PV adapter, it can safely measure DC voltages up to 2000 V and AC voltages up to 1500 V.

Is this answer helpful?

A

Yes, the device features Bluetooth 4.0 Low Energy. You can download the BENNING MM-CM Link app from the App Store or Google Play to view real-time data and export logs.

Is this answer helpful?

A

Yes, the HFR key activates an inrush current measurement function that captures average values over 100 milliseconds after a trigger event occurs.

Is this answer helpful?

A

Turn the rotary switch to OFF, remove the rear cover screws, lift the battery compartment lid, replace the two AA batteries with correct polarity, and secure the cover.

Is this answer helpful?

A

No, it has an IP 30 rating which protects against solid objects larger than 2.5 mm but offers no protection against water. It must be used in dry environments.

Is this answer helpful?

A

VoltSense allows for non-contact detection of alternating electric fields. It alerts users via sound and LED if a live phase is nearby without needing test leads.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Specialized PV mode supports measurements up to 2000 V DC with the TA PV adapter
  • Bluetooth connectivity allows wireless data transfer to smartphones and tablets
  • True RMS technology ensures accurate readings on non-sinusoidal waveforms
  • Built-in data logger stores up to 4000 measurements with customizable intervals
  • VoltSense feature enables safe non-contact voltage detection
VS

Disadvantages

  • Requires specific BENNING TA PV adapter for high-voltage PV measurements
  • Battery life may decrease significantly when using Bluetooth or backlight
  • Flexible AC current transformer is sold separately as an optional accessory
  • Not waterproof and requires dry environments for operation
  • Initial setup for data logger requires multiple button presses
M: QW-35-FL

Product Specification

Measurement range

max. 600A, max. 1000V, 600kΩ

M: QW-35-FL

Product Description

Benning CM 10-PV: The Ultimate Clamp Meter for Solar Professionals

The Benning CM 10-PV is a high-performance True RMS digital clamp meter designed specifically for the rigorous demands of photovoltaic systems and general electrical diagnostics. This versatile tool combines precision measurement capabilities with robust safety features, making it an essential asset for electricians working on solar installations up to 2000 V DC.

Engineered for efficiency, the device features a large digital display that clearly shows voltage, current, resistance, frequency, and temperature readings. Its standout capability is the specialized PV mode, which allows safe measurement of system voltages up to 1500 V DC when used with the included BENNING TA PV adapter. This adapter steps down the voltage, protecting both the user and the instrument from high-voltage hazards inherent in modern solar arrays.

Beyond standard measurements, the CM 10-PV offers advanced data logging functions. Users can record up to 4000 measurements automatically or manually at intervals ranging from one to sixty seconds. These logs can be transferred wirelessly via Bluetooth 4.0 to Android or iOS devices using the dedicated BENNING MM-CM Link app, enabling real-time analysis and CSV file generation for reporting purposes.

Safety is paramount with this unit. It complies with CAT III 1000 V and CAT IV 600 V standards for general use, ensuring reliable protection against transient overvoltages. The device includes a VoltSense function for non-contact voltage detection, helping technicians quickly identify live conductors without physical contact. Additionally, the built-in inrush current measurement helps diagnose motor start-up issues, while the flexible AC current transformer option extends its utility to high-current applications up to 3000 A.

Whether you are troubleshooting complex solar inverters or performing routine maintenance on industrial equipment, the Benning CM 10-PV delivers accuracy, durability, and ease of use in a compact, ergonomic design.