Manual.ly Logo

Benning CM 10-1 Manual

0.0 · 0 Ratings

PDF manual · 64 Pages

English

M: gpt-5.6-terra
page

/ 64

Loading...
c36e192fc0718547056c91fdfa8d2828c4c6 page 16
22
11/ 2019
BENNING CM 10–1
Operating Manual
BENNING CM 10-1
TRUE RMS digital current clamp Multimeter for
- DC/ AC voltage measurements
- DC/ AC current measurements
- resistance measurements
- continuity and diode tests
- capacity measurement
- frequency measurement
Table of contents
1. User instructions
2. Safety instructions
3. Scope of delivery
4. Device description
5. General information
5.1 General information
5.2 Data logger functions
5.2.1 Setting the data logger
5.2.2 Automatic storage (LOG)
5.2.3 Manual storage (SAVE)
5.3 Data transmission to the smartphone/ tablet
6. Ambient conditions
7. Electrical specifications
8. Measuring with the BENNING CM 10-1
9. Maintenance
10. Technical data of measuring accessories
11. Environmental note
1. User instructions
This operating manual is intended for
- skilled electricians and
- electrotechnically trained personnel.
The BENNING CM 10-1 is intended for measurements under dry ambient condi-
tions. It must not be used in electrical circuits with a nominal voltage higher than
1000 V AC/ DC (see section 6 „Ambient conditions“ for details).
The following symbols are used in this operating manual and on the BENNING
CM 10-1:
Application around and removal from HAZARDOUS LIVE conductors
is permitted.
Warning of electrical danger!
Indicates instructions which must be followed to avoid danger to per-
sons.
Attention! Must comply with documentation!
This symbol indicates that the information provided in the operating
man ual must be complied with in order to avoid risks.
CAT II
Measuring category II is applicable to testing and measuring circuits
which are directly connected to user connections (sockets and similar
connections) of the low-voltage mains installation.
CAT III
Measuring category III is applicable to testing and measuring circuits
connected to the distribution circuit of the low-voltage mains installation
of a building.
CAT IV
Measuring category IV is applicable to testing and measuring circuits
connected to the feed-in point of the low-voltage mains installation of
a building.
This symbol on the BENNING CM 10-1 indicates that the BENNING
CM 10-1 is equipped with protective insulation (protection class II).
Please observe the operating manual!
This symbol on the BENNING CM 10-1 means that the BENNING
CM 10-1 complies with the EU directives.

Chat with your Benning CM 10-1 manual using AI

Get instant AI answers from your Benning CM 10-1 manual

Ask anything about the Benning CM 10-1. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend CM 10-1?

Yes No

Frequently Asked Questions

A

It measures AC and DC voltage, AC and DC current, resistance, continuity, diode forward voltage, capacitance, and frequency. It also supports non-contact AC field detection, inrush current measurement, MIN/MAX capture, and low-pass filtering.

Is this answer helpful?

A

The clamp measures AC and DC current up to 1500 A. Its current ranges are 60 A, 600 A, and 1500 A. For flexible AC current measurements, the optional BENNING CFlex 1 accessory can be used with ranges up to 3000 A.

Is this answer helpful?

A

Yes. Bluetooth Low Energy 4.0 lets the meter send readings to compatible Android and iOS devices. The BENNING MM-CM Link app can show live values, save readings as CSV data, and retrieve logged measurements.

Is this answer helpful?

A

The internal logger stores up to 4,000 readings. Automatic logging intervals can be set to 1, 5, 10, 30, or 60 seconds. Manual storage is also available through the HOLD key.

Is this answer helpful?

A

LoZ AutoV automatically detects AC or DC voltage and selects a suitable range. Its low input impedance helps reduce misleading capacitive or inductive ghost voltages that can appear in electrical installations.

Is this answer helpful?

A

No. VoltSense detects an AC electric field without contact and can provide an LED and audible indication. The product guidance states that it is not intended to prove the absence of voltage, because hazardous voltage may still be present.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • TRUE RMS AC measurement and AC/DC clamp current measurement up to 1500 A support demanding electrical work.
  • Measures voltage, resistance, continuity, diodes, capacitance, and frequency in one compact instrument.
  • Bluetooth 4.0 and internal logging support real-time readings, CSV export, and storage of up to 4,000 values.
  • LoZ AutoV, INRUSH, HFR filtering, MIN/MAX, HOLD, backlight, and VoltSense add useful diagnostic capability.
  • Rated for CAT III 1000 V and CAT IV 600 V with the supplied capped safety leads.
VS

Disadvantages

  • Designed only for dry environments and has IP30 protection, with no water protection.
  • VoltSense non-contact detection cannot verify the absence of voltage and must not replace proper testing.
  • Starting automatic LOG or the first manual SAVE session clears previously stored logger values.
  • The optional BENNING CFlex 1 transformer is needed for flexible-loop AC current measurements up to 3000 A.
  • Specified accuracy changes outside the 18 C to 28 C reference range and with non-sinusoidal AC signals.
M: gpt-5.6-terra

Product Specification

Measurement range

max. 1,500 A, max. 1,000 V, max. 600 kOhm

M: gpt-5.6-terra

Product Description

Benning CM 10-1 Clamp Meter Multimeter - Read, Download & Print Free

The Benning CM 10-1 Clamp Meter Multimeter is a professional TRUE RMS measuring instrument designed for electrical testing, troubleshooting, installation work, and maintenance. It combines a current clamp with a versatile digital multimeter, allowing trained users to measure important electrical values with practical control options and clear on-screen results.

Its clamp jaw measures AC and DC current without disconnecting a conductor, making it useful for checking loads in distribution systems, motors, power circuits, and other electrical equipment. The jaw opens up to 42 mm and supports current ranges up to 1500 A AC/DC. For voltage work, the meter measures AC and DC voltage up to 1000 V, while the LoZ AutoV mode helps suppress ghost voltages and automatically identifies the appropriate AC or DC voltage range.

Broad Measurement Functions

Beyond voltage and current, the Benning CM 10-1 supports resistance, continuity, diode, capacitance, and frequency measurement. The continuity function provides both an audible buzzer and a red LED indication, helping users identify connected conductors quickly. Frequency measurement is available for both voltage and current signals, while capacitance testing supports checks of discharged capacitors up to 1000 uF.

Useful advanced functions include MIN/MAX recording, data hold, DC zero adjustment, display backlighting, and a low-pass HFR filter. The HFR filter is intended to reduce high-frequency interference when testing equipment such as variable-speed motor drives. An INRUSH mode captures starting current over a 100 ms interval, offering a practical way to evaluate motor and equipment startup behavior.

Logging and Wireless Data Access

The meter includes an internal logger that stores up to 4,000 measurements. Users can select automatic logging intervals from 1 to 60 seconds or save readings manually with the HOLD key. Bluetooth Low Energy 4.0 connectivity supports real-time viewing and transfer of readings to compatible Android or iOS devices through the BENNING MM-CM Link app. Logged results can be exported for later review, making the meter suitable for service records and trend monitoring.

The Benning CM 10-1 Clamp Meter Multimeter - Read, Download & Print Free is built for dry working conditions and offers CAT III 1000 V and CAT IV 600 V measurement ratings when used with the supplied protected test leads. It also includes non-contact VoltSense AC field detection, though this function should never be used alone to confirm that a circuit is de-energized.

Note: Always inspect the meter and test leads before use, use the correct measurement category, and follow qualified electrical safety practices. The instrument has IP30 protection and is not protected against water.

M: gpt-5.6-terra

© Copyright 2026 Manual.ly