73659d2461802acce55d13cff648b2c56008 page 14
20
07/ 2020
BENNING CM 1– 4
Operating Manual
BENNING CM 1-4
TRUE RMS multimeter with open current clamp for
- AC current measurements
- AC voltage measurements
- DC voltage measurements
- single-pole external conductor test (phase indication)
- phase sequence test
- polarity test
- resistance measurements
- continuity tests
Table of contents
1. User instructions
2. Safety instructions
3. Scope of delivery
4. Device description
5. General information
6. Ambient conditions
7. Electrical specifications
8. Measuring with the BENNING CM 1-4
9. Maintenance
10. Technical data of measuring accessories
11. Environmental note
1. User instructions
This operating manual is intended for
- skilled electricians and
- electrotechnically trained personnel.
The BENNING CM 1-4 is intended for measurements under dry ambient condi-
tions. It must not be used in electrical circuits with a voltage higher than 1000 V
AC/DC (see section 6 „Ambient conditions“ for details).
The following symbols are used in this operating manual and on the BENNING
CM 1-4:
Application around and removal from HAZARDOUS LIVE conductors
is permitted.
Warning of electrical danger!
Indicates instructions which must be followed to avoid danger to per-
sons.
Attention! Must comply with documentation!
This symbol indicates that the information provided in the operating
manual must be complied with in order to avoid risks.
CAT III
Measuring category III is applicable to testing and measuring circuits
connected to the distribution circuit of the low-voltage mains installation
of a building.
CAT IV
Measuring category IV is applicable to testing and measuring circuits
connected to the feed-in point of the low-voltage mains installation of
a building.
This symbol on the BENNING CM 1-4 indicates that the BENNING
CM 1-4 is equipped with protective insulation (protection class II).
Please observe the operating manual!
This symbol appears on the display to indicate a discharged battery.
This symbol designates the „continuity test“ eld. The buzzer is intended
for acoustic result output.
(DC) Direct voltage
(AC) Alternating voltage or current
Ground (voltage against ground)

Chat with your Benning CM 1-4 manual using AI

Get instant AI answers from your Benning CM 1-4 manual

Ask anything about the Benning CM 1-4. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend CM 1-4?

Yes No

Frequently Asked Questions

A

It measures AC current, AC voltage, DC voltage, resistance, continuity, polarity, phase sequence, and single-pole phase indication. It also provides TRUE RMS AC measurement capability.

Is this answer helpful?

A

The meter is rated for measurements up to 1000 V AC/DC. For installation categories, it is rated CAT III 1000 V and CAT IV 600 V when the supplied protective caps are installed on the probes.

Is this answer helpful?

A

Yes. Its open current clamp is designed to measure AC current on a single conductor without opening the circuit. The clamp opening is 16 mm and the AC current range reaches 200 A.

Is this answer helpful?

A

Its IP65 enclosure is dust-tight and protected against water jets, so it can be used in challenging field conditions. Follow the stated operating limits and use the instrument only in appropriate measurement environments.

Is this answer helpful?

A

TRUE RMS helps the meter provide more dependable AC readings when the waveform is distorted or non-sinusoidal. Accuracy can still vary with waveform crest factor and frequency, as specified for the instrument.

Is this answer helpful?

A

Yes. The continuity function gives an audible 2.7 kHz buzzer signal and an LED indication when resistance is below approximately 1.8 kOhm to 2.7 kOhm.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • TRUE RMS readings improve AC measurement reliability on non-sinusoidal signals.
  • Open clamp design measures AC current up to 200 A without disconnecting a conductor.
  • CAT III 1000 V and CAT IV 600 V ratings with protective caps support demanding electrical work.
  • IP65 housing is dust-tight and protected against water jets for field use.
  • Includes phase sequence, phase indication, continuity, resistance, hold, and work-light functions.
VS

Disadvantages

  • The current clamp measures AC current only; DC current measurement is not listed.
  • The 16 mm clamp opening may not fit larger conductors or bundled cables.
  • Measurements above 300 V are limited to 30 seconds, followed by a 240-second recovery period.
  • Resistance and continuity testing require the supplied test leads rather than the clamp.
  • It is intended for skilled electricians and electrically trained users, not casual use.
M: gpt-5.6-terra

Product Specification

Measurement range

max. 200 A, max. 1,000 V, max. 50 kOhm

Package contents

Test leads, belt holster, battery

M: gpt-5.6-terra

Product Description

Benning CM 1-4 Current Clamp Multimeter - Read, Download & Print Free

The Benning CM 1-4 Current Clamp Multimeter is a compact TRUE RMS testing instrument designed for electricians and trained electrical personnel who need dependable measurements in demanding environments. Its open current clamp makes AC current checks fast and practical, allowing a single conductor to be measured without disconnecting it. With a 16 mm clamp opening and a lightweight 200 g body, it is well suited to maintenance, installation, and troubleshooting work.

Versatile Electrical Testing

This meter combines essential electrical measurement functions in one rugged tool. It measures AC voltage and DC voltage from 6.0 V to 999.9 V when batteries are installed, with a maximum measurement rating of 1000 V. AC current measurement is available up to 200 A, while resistance testing covers values up to 50.00 kOhm. A built-in continuity function provides both an LED indication and an audible buzzer response for quick circuit checks.

TRUE RMS capability supports more reliable AC readings, especially where waveforms are not perfectly sinusoidal. The large digital display handles readings up to 9999 counts and includes AC/DC status, polarity, hold status, units, and battery capacity information. Automatic polarity indication and overload display add useful clarity during everyday diagnostic work.

Built for Field Safety

The Benning CM 1-4 is rated for CAT III 1000 V and CAT IV 600 V applications when the supplied protective caps are fitted to the test probes. Its IP65 enclosure is dust-tight and protected against water jets, helping it perform in outdoor and industrial conditions. The operating temperature range extends from -15 C to 55 C, making it a practical choice across many work sites.

Additional safety features include voltage warnings above 50 V AC or 120 V DC, a rubberized grip area, and a grip limit that helps keep hands away from live conductors. The instrument also performs a self-test at startup, briefly checking display segments and LED indicators.

Useful Features for Efficient Work

Beyond standard voltage and resistance measurements, the Benning CM 1-4 supports phase indication, phase sequence testing, and polarity testing. These functions are valuable when commissioning or servicing three-phase systems. The HOLD button stores a displayed reading, activates measurement-point illumination after a two-second press, and can control the voltage warning tone.

The package includes red and black safety leads, CAT III/IV protective caps, CAT II probe extensions, a contact-tip protector, a belt holster, and two AAA batteries. Automatic power-off helps preserve battery life, while the rear lead holder keeps accessories organized during transport and use.

Notes

  • Use only on suitable circuits within the stated category and voltage limits.
  • Inspect the meter and test leads before every use.
  • For best stated accuracy, regular annual calibration is recommended.