If the display is not visible during measurement, press the “HOLD”
button (3) to retain the display. The clamp can then be removed from
the conductor and the stored value read.
Voltage Measurements
Do not connect more than 600 V AC / DC to the input sockets. Exceeding
these values can endanger the operator, and may result in damage
to the instrument.
Before switching to a new function, disconnect the probes from
the UUT.
Only handle test leads and probes on the grips provided. Avoid tou-
ching the probes under any circumstances.
1) Turn selector switch (2) to 400V
2) Plug the black test lead into the “COM” socket and the red lead into
the “VΩ” socket
3) Connect the probes to the UUT and read the display
If the display is not visible during measurement, press the “HOLD”
button (3) to retain the display. The probes can then be removed from
the conductor and the stored value read.
7
40
mA
4
A
60
A
4
0
A
O
F
F
Z
ER
O
M
IN
/M
A
X
H
O
L
D
CO
M
0
10
20
30
40
60
0
V
A
C
40
0
mA

Chat with your Beha-Amprobe AC50A-D manual using AI

Get instant AI answers from your Beha-Amprobe AC50A-D manual

Ask anything about the Beha-Amprobe AC50A-D. Answers come from this manual, with the pages they are based on.

AC50A-D Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the instrument

Recommended calibration interval is one year to maintain accuracy. Shorter intervals are recommended for frequent or rough use; up to three years for infrequent use.

Show in the manual (page 10)
As needed
Clean the instrument

If dirty after daily usage, clean with a humid cloth and mild household detergent. Do not use acid detergents or solvents.

When low battery symbol appears
Replace the batteries

Change batteries when the low-battery symbol appears on the display. Use only 1.5V IEC LR6 alkaline batteries.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend AC50A-D?

Yes No
0
User Pic

Laura Schmidt

9 months ago

How are the shipping speed and product quality? Is the delivery reliable?

0
User Pic

Manual.ly

9 months ago

Based on customer feedback, both product quality and shipping experience are consistently rated positively. Buyers report being very satisfied with the shipment and delivery, and say the product matched expectations. If you order from the same store, you can generally expect a smooth process and dependable shipping. For the most accurate timeline, please check the estimated delivery window shown during checkout and the tracking information provided once your order ships.

M: OA-GPT-5-NAN
M: OA-GPT-5-NAN

Frequently Asked Questions

A

It is used to measure AC current, voltage, resistance, and continuity. Its clamp design is especially useful for checking current on live conductors without opening the circuit.

Is this answer helpful?

A

Yes. The manual highlights high sensitivity in the lower current ranges, making it suitable for leakage-current checks in some applications.

Is this answer helpful?

A

No. The meter uses manual range selection, so you choose the measurement range before taking a reading.

Is this answer helpful?

A

It is rated CAT II 600 V and follows relevant IEC/EN safety standards. Users should still follow all precautions and use it only within specified limits.

Is this answer helpful?

A

It includes data hold, MIN/MAX capture, zero setting, relative value measurement, an analog bargraph, and auto power-off.

Is this answer helpful?

A

Set the meter to resistance/continuity mode, connect the leads to COM and VΩ, and test the circuit. An audible signal sounds when resistance is below about 40 ohms.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Measures AC current, voltage, resistance, and continuity in one compact tool.
  • Clamp design allows safer current readings without disconnecting the circuit.
  • Helpful functions include HOLD, MIN/MAX, zero, relative value, and auto power-off.
  • Clear LCD plus bargraph improves readability during live measurements.
VS

Disadvantages

  • Manual range selection may be slower than auto-ranging meters for some users.
  • Limited to CAT II 600 V, so it is not meant for every high-energy application.
  • Clamp opening is about 30 mm, which may be restrictive for larger conductors.
  • Advanced users may find the feature set basic compared with modern multifunction meters.
M: OA-GPT-54-NAN

Product Specification

Measurement range

max. 60A, max. 600V

Display

yes

Special features

Automatic shutdown after 30min

Power supply

Battery operated (AA battery)

Dimensions

2.50x7.20x1.40in (WxHxD)

Weight

0.42lb

Scope of delivery

Test leads

M: OA-GPT-54-NAN

Product Description

Beha-Amprobe AC50A-D Clamp Multimeter

The Beha-Amprobe AC50A-D Clamp Multimeter is a practical choice for technicians who need a compact tool for everyday electrical checks. Built for current, voltage, resistance, and continuity measurements, it is especially useful when you want to inspect live conductors without breaking the circuit. The clamp design makes it convenient for field work, maintenance tasks, and troubleshooting in both industrial and trade environments.

A standout advantage of this meter is its sensitivity in lower current ranges, which helps with leakage-current checks and more precise diagnostics. The manual range selection keeps operation straightforward, while the data hold, MIN/MAX, zero setting, and relative value functions add flexibility during fast-moving inspections. The 3 3/4-digit LCD with bargraph support also makes readings easier to follow in changing conditions.

For users searching for the Beha-Amprobe AC50A-D Clamp Multimeter Manual, the most valuable takeaway is that the instrument is designed around safe, structured measurement habits. It supports clamp-based AC current readings up to 60 A, plus voltage and resistance testing through the input sockets. Continuity testing with audible feedback is another helpful feature for checking wiring and connections quickly.

The unit is also built with practical safety in mind. It follows relevant IEC/EN standards, includes overload protection, and uses a 30 mm clamp opening for common conductor sizes. Auto power-off helps preserve battery life, while the low-battery indicator and simple battery replacement process make upkeep easier over time.

Overall, this clamp multimeter fits users who want a dependable, easy-to-handle instrument for routine electrical measurement work. It is not overloaded with complex functions, but it covers the essentials well and adds enough convenience features to remain efficient in daily use.

Notes

  • Best suited for AC current, voltage, resistance, and continuity checks.
  • Useful for leakage-current detection in sensitive setups.
  • Keep it dry, clean, and within the stated measurement ranges.
  • Calibration is recommended regularly for consistent accuracy.