15
Id.Nr. 235161-13
General Installation and Warranty Terms
Operator‘s manual
Upright electric water heater
High-performance upright water heater
Multipurpose water heater
Auxiliary gas water heater
Built-in water heater
Solar upright water heater
Double-jacket upright water heater
Horizontal water heater
Please provide this document to the user
Dear customer,
You have selected our water heater for heating your water.
Thank you for the condence you have shown in us.
You have purchased an attractive unit which was constructed according to the state of the art and which meets all the approp-
riate regulations. Our continuously developed and improved enameling as well as constant quality inspection during production
give our water heaters technical advantages that will serve you for years to come.
Our CFC-free insulation ensures extraordinarily low standby-energy consumption.
Installation and startup should be performed only by an authorized installer according to this guide.
This short brochure contains all the essential instructions for proper installation and operation. Nevertheless, allow your installer
to explain the function of the appliance and how to operate it. Of course you may also contact our customer service and sales
department for any questions you have.
Please read these instructions carefully and in full. Keep them in a safe place and pass them on to any subsequent user.
We hope you enjoy your upright or horizontal water heater.
en

Chat with your Austria Email EHT manual using AI

Get instant AI answers from your Austria Email EHT manual

Ask anything about the Austria Email EHT. Answers come from this manual, with the pages they are based on.

EHT Maintenance Schedule

Remind me when maintenance is due
Yearly
Remove scale from interior boiler

If water has high lime content, remove scale from the inner tank by a technician every one to two operating years.

Show in the manual (page 11)
Every 2 years
Inspect and replace magnesium anode

Check the magnesium rod-type anode every 2 years and replace it when 2/3 of the material is consumed to ensure corrosion protection.

Show in the manual (page 10)
Every 2 years
Documented anode inspection for warranty

A specialist must document the anode inspection at maximum 2-year intervals to maintain warranty validity.

Show in the manual (page 11)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend EHT?

Yes No

Frequently Asked Questions

A

It provides the essential instructions for safe installation, electrical connection, commissioning, operation, maintenance, and proper shutdown for the Austria Email EHT hot water storage line. It also lists water quality, pressure, and corrosion protection requirements that directly affect performance and warranty validity.

Is this answer helpful?

A

No. The manual states installation, commissioning, and electrical connection must be carried out by qualified, authorized professionals. This is required for correct assembly, compliance with standards, and safe operation, especially for pressure-rated fittings and protective electrical measures.

Is this answer helpful?

A

The safety valve relieves expansion water during heating and protects the tank from overpressure. The manual also requires correct discharge routing (visible, open, and routed to drainage) and functional checks after filling so the system can vent safely and operate without blockages.

Is this answer helpful?

A

The enamelled tank is protected with a magnesium rod-type anode as standard, which must be inspected and replaced based on consumption intervals. For impressed current solutions, the manual explains LED-based monitoring, where green indicates active protection and red means protection is not active.

Is this answer helpful?

A

The manual calls for checking the magnesium anode every 2 years and replacing it when consumption reaches the specified level. For hard, lime-rich water, scale removal is typically required after about 1 to 2 operating years, using the specified cleaning method through the flange opening.

Is this answer helpful?

A

The manual requires defined limits for substances and a minimum conductivity to ensure corrosion protection works. If the requirements are not met or if decalcification is excessive, corrosion protection can fail and warranty claims may be rejected. It can also accelerate scaling and reduce efficiency.

Is this answer helpful?

A

Yes. The tank must be filled with water before connecting to electricity. During first filling, the outlet valve on the fitting is opened until the tank is completely filled with no air bubbles. After that, all connections are checked for leaks and the safety group is checked for proper function.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Durable enamel technology with factory quality inspection helps support long-term performance.
  • CFC-free insulation targets very low standby energy consumption for everyday efficiency.
  • Emphasis on correct safety valve use and discharge routing supports safe pressure management.
  • Built-in corrosion protection concepts with magnesium or impressed-current anode monitoring.
  • Clear guidance for commissioning, leak checks, and maintenance intervals to protect warranty validity.
VS

Disadvantages

  • Installation and electrical connection must be done by qualified specialists.
  • Strict requirements for water quality and conductivity may limit use with certain supplies.
  • Freeze protection and proper draining are required for periods of non-use.
  • Warranty and liability can be denied if approved fittings are not used or pressure limits are exceeded.
  • Regular maintenance is needed, including anode checks and scale removal after service intervals.
M: OA-GPT-54-NAN

Product Specification

Energy efficiency class

C

Temperature control

95-176°F

Construction type

closed (pressure-resistant)

Mounting type

Wall mounting

Special features

Frost protection

Noise level

15dB(A)

M: GO-GEM-FL-25

Product Description

Austria Email EHT Manual: A practical guide to safe, efficient hot water storage

If you want reliable hot water day after day, the Austria Email EHT line is built around performance and durability. These storage water heaters use state-of-the-art enamel technology and consistent factory quality checks, backed by CFC-free insulation designed for very low standby energy consumption. Whether the system is upright or horizontal, the goal is the same: dependable hot water with smart, service-friendly design.

A key part of getting the best results is following the Austria Email EHT Manual. Installation and first start-up must be carried out by qualified specialists, because the appliance depends on correct connections, correct pressure handling, and correct electrical safety measures. On the water side, the manual emphasizes pressure-tight connections using approved safety devices and correct discharge routing so expansion water can vent safely. On the electrical side, it requires proper protective equipment such as a residual current device (with I∆N <= 30 mA), correct wiring practices, and de-energizing before any work.

Beyond safety, the manual focuses strongly on corrosion protection and long-term operation. The enamelled tank is protected with a magnesium sacrificial anode as standard, and the guidance explains inspection and replacement intervals. For systems that use an impressed current anode, the Manual highlights monitoring via indicator LEDs, where green means protection is active. Water quality requirements are also central, including limits for substances and a minimum conductivity to support corrosion protection.

Proper operation also includes planning for freeze protection, preventing heat buildup during installation, and ensuring enough access for maintenance. During commissioning, the tank must be filled correctly and connections checked for leak-tightness, while the safety valve must function as intended during heating.

Notes for homeowners and installers

  • Use only suitable, tested fittings and do not exceed the rated pressure on the nameplate.
  • Keep the installation space frost-free and allow safe discharge of expansion water.
  • Follow the anode and scale removal intervals to protect the tank and maintain warranty validity.

Key results (most important takeaways)

  • Correct safety valve setup and open, visible discharge routing prevent unsafe pressure build-up and support reliable operation.
  • Water chemistry matters: pH and conductivity thresholds help corrosion protection work as designed.
  • Corrosion protection is not optional: anode inspection or LED monitoring is essential for long service life.
  • Maintenance is defined: scale cleaning through the specified flange opening helps preserve efficiency.
  • Freeze and access planning reduces secondary damage risks and makes future service possible.