ALE500N Maintenance Schedule
Have the interior of the device inspected by service staff once a year or more frequently depending on operating conditions.
Remove and clean the filter using a vacuum or mild soapy water (max 40 C) if heavily soiled. Do not expose to direct heat.
Free maintenance reminders
Timed to your purchase date. Always free, unsubscribe anytime.
Ask a Question
Do you recommend ALE500N?
Yes NoFrequently Asked Questions
The ALE500N can remove up to 50 liters of moisture per 24 hours under standard test conditions (30°C and 80% relative humidity). Actual performance depends on room temperature, air humidity and placement.
Is this answer helpful?
Yes. For continuous operation remove the tank plug and fit the supplied hose to the drain outlet; ensure the hose has a proper downward slope to an appropriate drain and is free of kinks for uninterrupted gravity drainage.
Is this answer helpful?
The recommended operating temperature range is 5–32°C. The built-in automatic defrost allows effective operation down to around +5°C by periodically defrosting the evaporator to prevent icing.
Is this answer helpful?
E3 indicates a humidity sensor fault, E4 signals the water collection tank is full, and E5 indicates a refrigeration circuit sensor fault. For E3 or E5 contact authorized service; E4 is resolved by emptying or correctly reseating the tank.
Is this answer helpful?
Place the unit centrally if possible with at least 10 cm clearance to walls, on a level surface and doors/windows closed to minimize humid air exchange. Keep it away from heat sources and ensure unobstructed intake and outlet airflow.
Is this answer helpful?
Clean the washable air filter regularly depending on operating conditions; light dirt can be vacuumed, heavier contamination washed in lukewarm soapy water (max 40°C) and fully dried before reinstalling.
Is this answer helpful?
Use a 230 V mains supply with a 10 A fuse and a 30 mA residual-current device (RCD). Extension cables should meet IEC 60245 (H07RN-F) with at least 1.5 mm² conductor for up to 25 m, or 2.5 mm² for longer runs.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- High dehumidification capacity (50 L/24h) suitable for post-flood drying and large damp spaces.
- Robust construction with transport handle and wheels for easy repositioning on job sites.
- Automatic defrost enables operation down to +5°C, extending usability in cooler conditions.
- Clear control panel with humidity readout, operating hours counter and diagnostic fault codes.
- Continuous drainage option with hose for unattended long-term operation.
Disadvantages
- Relatively heavy (30 kg), may be cumbersome to move without assistance despite wheels.
- Requires proper electrical protection (230 V, 10 A fuse, 30 mA RCD) which may need installer attention.
- Can be noisy (LWA < 70 dB), possibly unsuitable for quiet indoor environments.
- Performance depends on room sealing; effectiveness drops if doors/windows remain open.
- Tank capacity limited to 5.8 L unless continuous drainage is set up and correctly routed.
Product Specification
Power
800W
Color
orange, black
Recommended room size
up to 753.47 sq ft
Power levels
yes
Air circulation
206.00 cfm
Dehumidification capacity
105.67 pints/24h
Refrigerant
R410a
Ambient temperature
+41.00°F to +89.60°F
Condensate tank capacity
1.53 gal
Filtering
washable air filter
Special features
Castors, Hygrostat, Automatic shutdown, Connection option for direct condensate drain
Noise level
max. 66dB(A)
Weight
66.14 lbs
Product Description
Atika ALE500N Dehumidifier — Reliable Moisture Control
The Atika ALE500N Dehumidifier is a heavy-duty condensation dehumidifier designed for indoor use where fast, reliable moisture removal is required. With a rated dehumidification capacity of up to 50 L/24h (at 30°C/80% RH), a 350 m³/h airflow and robust 800–920 W power range, it suits drying wet walls after water damage, continuous dehumidification in damp rooms, or maintaining comfortable indoor humidity between 30–90% RH. The unit uses an R410a refrigerant circuit with automatic defrosting to allow operation down to +5°C, and a built-in float switch cuts power when the 5.8 L tank is full; continuous drainage via hose is supported for extended operation.
The ALE500N is engineered for professional and domestic applications: a sturdy transport handle, wheels, and detachable legs make positioning easy, and a clear LED/control panel shows relative humidity, operating hours and fault codes (E3/E4/E5). Safety and electrical requirements are emphasized — 230 V, 10 A fuse protection, and a 30 mA residual-current device are recommended. The operating range is 5–32°C and recommended target indoor humidity is typically 50–60% for comfort and to avoid condensation. Filters are washable; routine cleaning and yearly service keep performance optimal.
Operation centers on the condensation principle: room air is drawn through a filter and cooled evaporator where moisture condenses into a collection tank while warmed, drier air returns to the room. Proper placement (minimum 10 cm from walls, centrally if possible) and sealing of doors/windows improve efficiency. Built-in protections include compressor-run timing to prevent damage (3-minute minimum run/ restart delay), audible alarms for tank-full, and diagnostic codes for sensor faults. The dehumidifier complies with applicable EU directives and harmonized safety standards.
For maintenance, remove and clean the washable air filter regularly, empty or plumb the tank for continuous use, and avoid transporting the unit on its side — allow at least one hour upright after tilting. If faults persist, the manual advises contacting authorized service and using original spare parts to avoid hazards.
Notes:
- Ideal for drying rooms after water damage and for continuous dehumidification in enclosed spaces.
- Supports continuous drainage; ensure hose has proper downward slope and no kinks.
- Recommended RH setpoint: 50–60% for comfort and condensation prevention.
- Observe electrical requirements and safety instructions; children under 16 should not operate the unit.
Quick specs
- Model: ALE 500 N
- Dehumidification: 50 L/24h (30°C/80% RH)
- Airflow: 350 m³/h
- Power: 800 W (nominal), 920 W (max)
- Refrigerant: R410a (0.405 kg)
- Tank: max 5.8 L (LED at 3.9 L)
- Operating temp: 5–32°C
- Weight: 30 kg
Search for 67,706 Manuals online