Manual.ly Logo

Atika ALE500N Manual

0.0 · 0 Ratings

PDF manual · 144 Pages

English

M: OA-GPT-5-NAN
page

/ 144

Loading...
cecbc4cb698a1086ee2d0586e4786749e3a5 page d
13
You may not start to operate the machine
until you have read these operating
instructions, observed all the instructions
given and installed the machine as described!
Keep the operating instructions in a safe place for future
use.
Electrical devices do not go into the domestic rubbish.
Give devices, accessories and packaging to an
ecofriendly recycling.
According to the European Directive 2012/19/EU on electrical
and electronic scrap, electrical devices that are no longer
serviceable must be separat
ely collected and brought to a
facility for an environmentally compatible recycling.
C
C
o
o
n
n
t
t
e
e
n
n
t
t
s
s
EC Declaration of Conformity 13
Extent of delivery 13
Symbols on the machine 13
Symbols in the operating instructions 14
Proper use 14
Residual risks 14
Security advices 14
Electrical safety advices 14
Function principle
15
Assembly 15
Location of the air dehumidifier 16
Location 16
Electric supply 16
Power system fuse protection
16
Start-up 16
Before starting up 16
Control panel 17
Powering up 17
Shutting down 17
Setting the humidity 17
Automatic defroster 17
Operating hour counter 17
Water outlet
18
Removing the water collecting container 18
Continuous or extended operation 18
Transport
18
Cleaning and maintenance 19
Cleaning the air filter 19
Removing the filter 19
Inserting the filter 19
Cleaning the device 19
Maintenance 19
Storage
19
Guarantee 19
Possible faults 20
Fault code 20
Technical specifications
21
Wiring diagram 21
Refrigerant circuit 22
Spare parts 22
E
E
C
C
D
D
e
e
c
c
l
l
a
a
r
r
a
a
t
t
i
i
o
o
n
n
o
o
f
f
C
C
o
o
n
n
f
f
o
o
r
r
m
m
i
i
t
t
y
y
No. (S-No.): 14778
according to Directive 2014/35/EU
We,
ATIKA GmbH
Josef-Drexler-Str. 8, 89331 Burgau - Germany
Here with declare under our sole responsibility that the product
Luftentfeuchter (Air dehumidifier) type / model ALE 500 N
Serial number: 000001 – 020000
is conform with the above mentioned EC directives as well as
with the provisions of the guidelines below:
2014/30/EU and 2011/65/EU.
Following harmonized standards have been applied:
EN 60335-1:2012+A11:2014;
EN 60335-2-40:2003+A11:2004+A12:2005+A1:2006+A2:2009+
A13:2012; EN 62233:2008;
EN 55014-1:2006+A1:2009+A2:2011;
EN 55014-2:1997+A1:2001 +A2:2008;
EN 61000-3-2:2014; EN 61000-3-3:2013.
Keeping of technical documents at:
ATIKA GmbH -Technical bureau, Josef-Drexler-Str. 8,
89331 Burgau - Germany
i.A.
Burgau, 09.03.2017 i.A. G. Koppenstein
Engineering design management
E
E
x
x
t
t
e
e
n
n
t
t
o
o
f
f
d
d
e
e
l
l
i
i
v
v
e
e
r
r
y
y
After unpacking, check the contents of the box for
completeness
possible transport damage.
Report any damage or missing items to your dealer, supplier or
the manufacturer immediately. Complaints made at a later date
will not be acknowledged.
• pre-assembled device unit
• leg right / left
• 1 carrying handle
• 1 screw bag
• 2 wheels
• 1 hose
• 1 operating instruction
manual
• Warranty card
S
S
y
y
m
m
b
b
o
o
l
l
s
s
o
o
n
n
t
t
h
h
e
e
m
m
a
a
c
c
h
h
i
i
n
n
e
e
Read and follow the operating instructions
and safety advices before starting up the
machine.
Switch off the air dehumidifier and
disconnect the mains power plug before
performing cleaning, maintenance or
repair work.
Do not tilt the air dehumidifier
and do not
transport it in horizontal position.

Chat with your Atika ALE500N manual using AI

Get instant AI answers from your Atika ALE500N manual

Ask anything about the Atika ALE500N. Answers come from this manual, with the pages they are based on.

ALE500N Maintenance Schedule

Remind me when maintenance is due
Yearly
Inspect interior for contamination

Have the interior of the device inspected by service staff once a year or more frequently depending on operating conditions.

Regular intervals depending on operating conditions
Clean air filter

Remove and clean the filter using a vacuum or mild soapy water (max 40 C) if heavily soiled. Do not expose to direct heat.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend ALE500N?

Yes No

Frequently Asked Questions

A

The ALE500N can remove up to 50 liters of moisture per 24 hours under standard test conditions (30°C and 80% relative humidity). Actual performance depends on room temperature, air humidity and placement.

Is this answer helpful?

A

Yes. For continuous operation remove the tank plug and fit the supplied hose to the drain outlet; ensure the hose has a proper downward slope to an appropriate drain and is free of kinks for uninterrupted gravity drainage.

Is this answer helpful?

A

The recommended operating temperature range is 5–32°C. The built-in automatic defrost allows effective operation down to around +5°C by periodically defrosting the evaporator to prevent icing.

Is this answer helpful?

A

E3 indicates a humidity sensor fault, E4 signals the water collection tank is full, and E5 indicates a refrigeration circuit sensor fault. For E3 or E5 contact authorized service; E4 is resolved by emptying or correctly reseating the tank.

Is this answer helpful?

A

Place the unit centrally if possible with at least 10 cm clearance to walls, on a level surface and doors/windows closed to minimize humid air exchange. Keep it away from heat sources and ensure unobstructed intake and outlet airflow.

Is this answer helpful?

A

Clean the washable air filter regularly depending on operating conditions; light dirt can be vacuumed, heavier contamination washed in lukewarm soapy water (max 40°C) and fully dried before reinstalling.

Is this answer helpful?

A

Use a 230 V mains supply with a 10 A fuse and a 30 mA residual-current device (RCD). Extension cables should meet IEC 60245 (H07RN-F) with at least 1.5 mm² conductor for up to 25 m, or 2.5 mm² for longer runs.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High dehumidification capacity (50 L/24h) suitable for post-flood drying and large damp spaces.
  • Robust construction with transport handle and wheels for easy repositioning on job sites.
  • Automatic defrost enables operation down to +5°C, extending usability in cooler conditions.
  • Clear control panel with humidity readout, operating hours counter and diagnostic fault codes.
  • Continuous drainage option with hose for unattended long-term operation.
VS

Disadvantages

  • Relatively heavy (30 kg), may be cumbersome to move without assistance despite wheels.
  • Requires proper electrical protection (230 V, 10 A fuse, 30 mA RCD) which may need installer attention.
  • Can be noisy (LWA < 70 dB), possibly unsuitable for quiet indoor environments.
  • Performance depends on room sealing; effectiveness drops if doors/windows remain open.
  • Tank capacity limited to 5.8 L unless continuous drainage is set up and correctly routed.
M: OA-GPT-5-NAN

Product Specification

Power

800W

Color

orange, black

Recommended room size

up to 753.47 sq ft

Power levels

yes

Air circulation

206.00 cfm

Dehumidification capacity

105.67 pints/24h

Refrigerant

R410a

Ambient temperature

+41.00°F to +89.60°F

Condensate tank capacity

1.53 gal

Filtering

washable air filter

Special features

Castors, Hygrostat, Automatic shutdown, Connection option for direct condensate drain

Noise level

max. 66dB(A)

Weight

66.14 lbs

M: OA-GPT-54-NAN

Product Description

Atika ALE500N Dehumidifier — Reliable Moisture Control

The Atika ALE500N Dehumidifier is a heavy-duty condensation dehumidifier designed for indoor use where fast, reliable moisture removal is required. With a rated dehumidification capacity of up to 50 L/24h (at 30°C/80% RH), a 350 m³/h airflow and robust 800–920 W power range, it suits drying wet walls after water damage, continuous dehumidification in damp rooms, or maintaining comfortable indoor humidity between 30–90% RH. The unit uses an R410a refrigerant circuit with automatic defrosting to allow operation down to +5°C, and a built-in float switch cuts power when the 5.8 L tank is full; continuous drainage via hose is supported for extended operation.

The ALE500N is engineered for professional and domestic applications: a sturdy transport handle, wheels, and detachable legs make positioning easy, and a clear LED/control panel shows relative humidity, operating hours and fault codes (E3/E4/E5). Safety and electrical requirements are emphasized — 230 V, 10 A fuse protection, and a 30 mA residual-current device are recommended. The operating range is 5–32°C and recommended target indoor humidity is typically 50–60% for comfort and to avoid condensation. Filters are washable; routine cleaning and yearly service keep performance optimal.

Operation centers on the condensation principle: room air is drawn through a filter and cooled evaporator where moisture condenses into a collection tank while warmed, drier air returns to the room. Proper placement (minimum 10 cm from walls, centrally if possible) and sealing of doors/windows improve efficiency. Built-in protections include compressor-run timing to prevent damage (3-minute minimum run/ restart delay), audible alarms for tank-full, and diagnostic codes for sensor faults. The dehumidifier complies with applicable EU directives and harmonized safety standards.

For maintenance, remove and clean the washable air filter regularly, empty or plumb the tank for continuous use, and avoid transporting the unit on its side — allow at least one hour upright after tilting. If faults persist, the manual advises contacting authorized service and using original spare parts to avoid hazards.

Notes:

  • Ideal for drying rooms after water damage and for continuous dehumidification in enclosed spaces.
  • Supports continuous drainage; ensure hose has proper downward slope and no kinks.
  • Recommended RH setpoint: 50–60% for comfort and condensation prevention.
  • Observe electrical requirements and safety instructions; children under 16 should not operate the unit.

Quick specs

  • Model: ALE 500 N
  • Dehumidification: 50 L/24h (30°C/80% RH)
  • Airflow: 350 m³/h
  • Power: 800 W (nominal), 920 W (max)
  • Refrigerant: R410a (0.405 kg)
  • Tank: max 5.8 L (LED at 3.9 L)
  • Operating temp: 5–32°C
  • Weight: 30 kg
M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly