e8c6023938d0c4592f26a219bfafc15ae19f page a
IMPORTANT:
Before using the appliance for the rst time, rinse out both the ne lter and the carbon lter thoroughly before
reconnecting the hose to the membrane housing.
You can now reconnect the hose to the membrane housing and use the osmosis system. To do this, please proceed as follows:
1. Press the white ring on the hose connection back inwards.
2. Insert the hose into the hose connection as far as it will go.
3. Now reattach the blue circlip.
4. Check that the connection is secure and correct by pulling lightly on the hose.
Step 2: Correct use
IMPORTANT:
Only connect the osmosis system to cold water pipes (max. 30° water temperature) to prevent premature wear of the
membrane and deterioration of the retention rates.
1. Close the ushing valve (4) by turning the lever to a 90° position to the valve.
2. Connect the water tap connection of the osmosis system to a 3/4“ water tap (in some cases an additional adapter is
necessary, which is not included in the scope of delivery). First route the hoses for residual and osmosis water into
a drain.
IMPORTANT:
Make sure that the water pressure of the connected water pipe is correct; it should be at least 3 bar. At a water pressure of
4 bar, the osmosis system reaches its nominal capacity. A water pressure below 3 bar results in a lower pure water output.
A water pressure of less than 2 bar also reduces the attainable retention rates.
3. Connect the tap connection and tap water inlet (6) of the ne lter using an appropriately long piece of the supplied hose.
4. Now open the tap carefully and only a little at rst. After a successful leak test of the individual components, you can turn
on the tap completely. Then please let the osmosis system run for 30–60 minutes so that the preservative contained in
the membrane washes out thoroughly. The osmosis water produced during this time should NOT be used and should be
discharged into the drain.
5. After the system has been ushed, it can now be used to produce osmosis water.
IMPORTANT:
Make sure that both the escaping osmosis water and the wastewater can always drain o freely.
10

Chat with your ARKA myAQUA 190/380 manual using AI

Get instant AI answers from your ARKA myAQUA 190/380 manual

Ask anything about the ARKA myAQUA 190/380. Answers come from this manual, with the pages they are based on.

myAQUA 190/380 Maintenance Schedule

After each use
Flush the system

Use the integrated flush valve for 5 minutes to prevent limescale and dirt accumulation on the membrane.

Show in the manual (page 11)
Before first use
Rinse filters

Thoroughly rinse both the fine filter and carbon filter before connecting them to the membrane housing.

Show in the manual (page 10)
After 2 weeks of inactivity
Flush after storage

If the unit is not used for more than 2 weeks, rinse it for 30-60 minutes before using again.

Show in the manual (page 11)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend myAQUA 190/380?

Yes No

Frequently Asked Questions

A

The ARKA myAQUA® 190 produces up to 190 liters per 24 hours and the ARKA myAQUA® 380 up to 380 liters per 24 hours under recommended conditions (cold water and sufficient pressure).

Is this answer helpful?

A

A minimum feed pressure of 3 bar is recommended. The system reaches nominal capacity around 4 bar. Pressures below 3 bar reduce pure water output; below 2 bar, retention rates may also decline.

Is this answer helpful?

A

Flush the system regularly (a 5-minute rinse after each use is recommended), replace prefilters and membrane per indicated intervals, rinse new cartridges before installation, and perform a 30–60 minute flush after inactivity longer than two weeks.

Is this answer helpful?

A

No. Only connect to cold water with temperatures up to 30°C. Hot water can damage the membrane, cause premature wear and lower retention performance.

Is this answer helpful?

A

Yes. Resin filters (RF300, RF500) and a multi-filter (MF500) are available as an optional fourth stage to reduce silicates, nitrates and other dissolved solids (TDS).

Is this answer helpful?

A

Typical wastewater ratio is about 1:3–4 (one part pure water to three or four parts waste). Actual efficiency depends on feed pressure and installation specifics.

Is this answer helpful?

A

Thoroughly rinse the fine and carbon prefilters, run the system for 30–60 minutes to flush out the membrane preservative, and discard that initial output to the drain before collecting osmosis water.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High rejection rates: removes up to 98–99% of salts, pollutants and bacteria.
  • Simple maintenance: integrated flush valve and easy cartridge replacement.
  • Good capacity: 190 L and 380 L per day models for hobby and small pro setups.
  • Compact aquarium-focused design with included mounting hardware.
  • Expandable with optional resin/multi-filters for advanced TDS reduction.
VS

Disadvantages

  • Requires minimum 3 bar water pressure for rated performance.
  • Only cold-water connection allowed (max 30°C).
  • Initial membrane purge wastes 30–60 minutes of water.
  • Waste water ratio around 1:3–4 reduces overall efficiency.
  • Some tap adapters may not be included and need purchase.
M: OA-GPT-5-NAN

Product Specification

Suitability

Freshwater, Seawater

M: OA-GPT-54-NAN

Product Description

ARKA myAQUA Osmoseanlage Manual — ARKA myAQUA® 190/380

The ARKA myAQUA Osmoseanlage Manual introduces the ARKA myAQUA® 190 and 380 reverse osmosis systems designed for aquarium use. These compact units filter up to 98–99% of salts, pollutants, bacteria and heavy metals using a three-stage filtration process: a 5-micron fine filter, an activated carbon filter, and an ultrafine TFM polyamide/polysulfone membrane. With daily output ratings of up to 190 L and 380 L respectively, the systems are suited for hobbyists and small professional setups that require highly purified water.

Product overview and features

The system relies on household water pressure (recommended 3–8 bar) to push tap water through the prefilters and membrane. A flow limiter maintains the waste-to-pure-water ratio at about 1:3–4. The included flushing valve allows easy membrane cleaning and routine rinsing. Temperature operating range is 1–30°C; the membrane’s pore size is 0.0001 micron, ensuring removal of microscopic contaminants. Scope of delivery includes membrane and housing, filter cartridges, tubing, brackets and basic connectors.

Installation and use

Mount the supplied wall brackets, install the membrane in the housing following flow direction markers, and securely connect provided tubing using the push-fit fittings and blue safety clips. Before first use, thoroughly rinse the fine and carbon filters and run the unit for 30–60 minutes to purge membrane preservative; discard initial effluent. Connect only to cold water (max 30°C) and ensure minimum water pressure of 3 bar for proper performance. Route both permeate and waste to a drain during setup and testing.

Maintenance and optional upgrades

Maintenance is straightforward: regular flushing (a recommended 5-minute flush after each use) prevents scale and fouling. Replace prefilters and membrane per indicated intervals; always rinse new cartridges before installation. Protect the membrane from drying and freezing. If unused for more than two weeks, flush for 30–60 minutes prior to reactivation. Optional resin or multi-filters can be added as a fourth stage to reduce silicates, nitrates and residual TDS.

Notes

  • Ensure correct water pressure (3–8 bar) and cold-water connection only.
  • Discard the first flush water after membrane installation for 30–60 minutes.
  • Protect membrane from freezing or drying.
  • Optional resin filters available (RF300, RF500) and a multi-filter MF500.

Pros and Cons

Pros:

  • High rejection rates: up to 98–99% salt and contaminant removal.
  • Simple maintenance: integrated flush valve and easy cartridge changes.
  • Decent capacity: models produce up to 190 L or 380 L per day.
  • Compact and aquarium-focused design with included mounting hardware.
  • Expandable: optional resin/multi-filters for advanced TDS reduction.

Cons:

  • Requires minimum 3 bar water pressure for rated performance.
  • Not suitable for hot water supply (max 30°C only).
  • Initial membrane purge wastes 30–60 minutes of water.
  • Produces waste water at a 1:3–4 ratio (consumption vs. waste).
  • Some adapters for tap connection may not be included.

Top results / key takeaways

  • Filtration effectiveness: Removes up to 98–99% of salts, pollutants, bacteria and heavy metals; suitable for both freshwater and marine aquaria.
  • Flow & capacity: ARKA myAQUA® 190 and 380 deliver up to 190 L and 380 L per day, with a waste-to-pure ratio around 1:3–4.
  • Operating requirements: Requires cold water only (≤30°C) and recommended water pressure ≥3 bar for rated output.
  • Maintenance routine: Regular 5-minute flush after use, rinse new cartridges, and 30–60 minute flush after prolonged inactivity.
  • Upgrade path: Optional resin and multi-filters (RF300, RF500, MF500) provide extra TDS, silicate and nitrate reduction.

FAQ

  • Question: What daily output can I expect from ARKA myAQUA models? Answer: The ARKA myAQUA® 190 supplies up to 190 L/24h and the 380 up to 380 L/24h under recommended conditions (cold water, adequate pressure).

  • Question: What water pressure is needed for proper operation? Answer: A minimum of 3 bar is required; the unit reaches nominal capacity at about 4 bar. Pressures below 2–3 bar reduce output and retention performance.

  • Question: How often should I flush or maintain the system? Answer: Flush for about 5 minutes after each use to avoid fouling. Replace prefilters and membrane per manufacturer intervals, rinse replacements before installing, and if unused over 2 weeks, flush 30–60 minutes before use.

  • Question: Can I connect the system to hot water or outdoor taps? Answer: No — only cold water up to 30°C. Hot water can damage the membrane and reduce retention rates.

  • Question: What additional filters are available and why add them? Answer: Optional resin filters (RF300, RF500) and a multi-filter (MF500) can be added as a fourth stage to remove silicates, nitrates and lower TDS levels for sensitive aquarium environments.

  • Question: Is a lot of water wasted during filtration? Answer: The unit typically wastes water at a ratio of about 1:3–4 (pure:waste). Efficiency depends on feed pressure and system configuration.

  • Question: What should I do before first use? Answer: Thoroughly rinse the fine and carbon filters, run the system 30–60 minutes to flush membrane preservative, and discard that initial output to drain.

M: OA-GPT-5-NAN