Manual.ly Logo

Aqua Computer ULTITOP D5 Manual

5.0 · 1 Ratings

PDF manual · 1 Pages

English

M: QW-35-FL
page

/ 1

Loading...
b016b31470f06c0102d33078571d5c0d4c81 page 1
ULTITOP D5
ULTITOP D5
ULTITOP D5ULTITOP D5
ULTITOP D5
User and installation manual
User and installation manualUser and installation manual
User and installation manual
Description
DescriptionDescription
Description
Exceptionally compact top for D5 pumps, made from durable acetal (41123) or
manually polished brass with dark nickel plating (41133). Main focus during de-
velopment of the ULTITOP D5 were optimum flow characteristics, reducing noise
and vibration to a bare minimum.
A fastening ring made from anodized aluminum and a gasket are supplied to at-
tach a D5 pump (not included in delivery) to the ULTITOP. The mounting bracket
is equipped with silicone decouplers specifically designed for the ULTITOP, effec-
tively preventing remaining vibrations from being transmitted to the PC case. Stain-
less steel plates with M3 threads inserted into the decouplers ensure convenient in-
stallation. The bracket can be detached from the ULTITOP by removing a single
screw for easy access to the pump.
Installation of a D5 pump motor
Installation of a D5 pump motorInstallation of a D5 pump motor
Installation of a D5 pump motor
If you have a complete D5 pump instead of a D5 pump motor, you will have to
disassemble the pump first. The only parts needed are the housing with electronic
components and the impeller.
Install the pump motor as follows:
1. Place the gasket into the ULTITOP base part.
2. Place the D5 pump motor on top of the ULTITOP base part.
3. D5 NEXT only: Remove the controller unit from the pump
4. Slide the mounting ring onto the rear side of the pump motor and fasten the
ring by screwing it onto the ULTITOP base part.
5. D5 NEXT only: Re-attach the controller unit to the pump.
Integration into coolant loop
Integration into coolant loopIntegration into coolant loop
Integration into coolant loop
Connect the return line to the central connector of the ULTITOP D5 (engraved
“IN”) and connect the other line to the lateral connector. Use light force only when
screwing in fittings in order not to damage the threads in the plastic base part!
Replacement part information
Replacement part informationReplacement part information
Replacement part information
Gasket: 94767
© 2018-2020 Aqua Computer GmbH & Co. KG 94773
Gelliehäuser Str. 1, 37130 Gleichen
c
o
m
p
u
t
e
r
a
q
u
a

Chat with your Aqua Computer ULTITOP D5 manual using AI

Get instant AI answers from your Aqua Computer ULTITOP D5 manual

Ask anything about the Aqua Computer ULTITOP D5. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend ULTITOP D5?

Yes No
0
User Pic

Lena Vogel

9 months ago

Are these fittings completely leak-proof when used with D5 Next RGB pumps, or do they loosen over time?

0
User Pic

Manual.ly

9 months ago

Based on customer feedback, they hold perfectly on D5 Next RGB pumps and stay tight without leaks. For best results, make sure you install the fitting correctly, use the right size, and confirm the O-ring is seated properly. Tighten by hand first and then snug it gently (do not overtighten). After installation, we recommend checking for leaks once during the first run and again after a short period to ensure everything is seated correctly.

M: OA-GPT-5-NAN
M: OA-GPT-5-NAN
0
User Pic

WaterCoolingFan

6 months ago

Do these fittings stay leak-proof when used with D5 Next RGB pumps?

0
User Pic

Manual.ly

6 months ago

Yes, our fittings are designed to remain absolutely tight and leak-proof even when installed on D5 Next RGB pumps. Many customers have confirmed their reliability under high pressure, making them a recommended choice for your build.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Scott Roberts

5 months ago

Are these compatible with the D5 Next RGB pump setup without any leaks over time?

M: QW-35-FL

Frequently Asked Questions

A

It is manufactured from robust Acetal or hand-polished dark nickel-plated brass.

Is this answer helpful?

A

No, the D5 pump is sold separately and must be purchased independently.

Is this answer helpful?

A

Connect the return line to the central IN port and the other line to the side port.

Is this answer helpful?

A

Yes, silicone decouplers with stainless steel inserts prevent vibration transfer to the case.

Is this answer helpful?

A

Yes, but you must remove and reinstall the control unit during the mounting process.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Extremely quiet operation due to optimized flow behavior
  • Vibration isolation prevents noise transfer to the case
  • Available in durable Acetal or premium nickel-plated brass
  • Single-screw release allows easy pump access
  • Compact design fits well in tight spaces
VS

Disadvantages

  • D5 pump is not included in the package
  • Hand-tightening requirement demands careful handling
  • Complex disassembly needed for full D5 pump integration
  • Silicone decouplers require specific M3 hardware
  • Control unit must be removed for D5 NEXT models
M: QW-35-FL

Product Specification

Type

Pump attachment for D5

Material

Stainless steel, POM (black)

Flow rate

N/A

Head height

N/A

Connections

G1/4"

Power connection

N/A

Dimensions

2.83x3.39x1.73 in

Features

includes bracket

M: QW-35-FL

Product Description

Experience Silence with the Aqua Computer ULTITOP D5 Manual

The Aqua Computer ULTITOP D5 represents a pinnacle of engineering for enthusiasts seeking high-performance liquid cooling solutions. Designed specifically for D5 pumps, this top unit offers an extremely compact footprint while delivering superior flow characteristics. The result is a system that operates with exceptional quietness and smooth running stability, making it ideal for build environments where noise reduction is paramount.

Constructed from either durable Acetal or hand-polished dark nickel-plated brass, the ULTITOP D5 ensures longevity and aesthetic appeal. The development process focused heavily on optimizing fluid dynamics to minimize turbulence and noise. To ensure a secure fit, the package includes an anodized aluminum mounting ring and a compatible gasket. A standout feature is the dedicated mounting bracket equipped with specialized silicone decouplers. These components effectively isolate vibrations, preventing them from transferring into the computer chassis.

Installation is streamlined for user convenience. Stainless steel plates with M3 threads are embedded within the silicone decouplers to facilitate easy assembly. The entire bracket can be detached by removing just a single screw, granting straightforward access to the pump for maintenance or upgrades. When integrating a complete D5 pump rather than just the motor, users must first disassemble the unit to utilize only the motor housing containing the electronics and impeller. The installation sequence involves placing the gasket, positioning the motor, and securing the ring. For D5 NEXT models, the control unit requires temporary removal and reinstallation during this process.

Integration into a cooling loop is intuitive. The central threaded port marked IN connects to the return line, while the side port handles the outlet. It is crucial to tighten these connections by hand only to avoid damaging the delicate threads of the pump adapter. This attention to detail in design and documentation ensures a reliable and efficient cooling solution for demanding PC builds.

M: QW-35-FL

© Copyright 2026 Manual.ly