Manual.ly Logo

aponorm Professional Manual

0.0 · 0 Ratings

PDF manual · 18 Pages

English

M: qwen/qwen3.5-flash-20260224
page

/ 18

Loading...
c3e9e9bee677b1c6137529da631794b97d4c page c
aponorm
®
by
24
Memory full
Pay attention that the maximum memory capacity of 99
memories per user is not exceeded. When the 99
memory is full, the oldest value is automatically
overwritten with the 100th value. Values should be
evaluated by a doctor before the memory capacity is
reached – otherwise data will be lost.
Clearing all values
1. Select either user 1 or 2 with the user switch
9
, when the
device is switched on.
2. Hold down the M-button
11
until «CL» appears and then
release the button.
3. Press the M-button while «CL» is flashing to permanently
clear all values of the selected user.
Cancel deletion: press START/STOP button
1
while
«CL» is flashing.
Individual values cannot be cleared.
9. Battery Indicator and Battery change
Low battery
When the batteries are approximately ¾ empty the battery
symbol
20
will flash as soon as the device is switched on (partly
filled battery displayed). Although the device will continue to
measure reliably, you should obtain replacement batteries.
Flat battery – replacement
When the batteries are flat, the battery symbol
20
will flash as
soon as the device is switched on (flat battery displayed). You
cannot take any further measurements and must replace the
batteries.
1. Open the battery compartment
5
on the bottom of the
device.
2. Replace the batteries – ensure correct polarity as shown by
the symbols in the compartment.
3. To set date and time, follow the procedure described in
«Section 3.».
The memory retains all values although date and time
must be reset – the year number therefore flashes auto
-
matically after the batteries are replaced.
Which batteries and which procedure?
Use 4 new, long-life 1.5 V, size AAA batteries.
Do not use batteries beyond their date of expiry.
Remove batteries if the device is not going to be used for
a prolonged period.
Using rechargeable batteries
You can also operate this device using rechargeable batteries.
Only use «NiMH» type reusable batteries.
Batteries must be removed and recharged when the flat
battery symbol appears. They should not remain inside the
device as they may become damaged (total discharge as a
result of low use of the device, even when switched off).
Always remove the rechargeable batteries if you do not
intend to use the device for a week or more.
Batteries cannot be charged in the blood pressure monitor.
Recharge batteries in an external charger and observe the
information regarding charging, care and durability.

Chat with your aponorm Professional manual using AI

Get instant AI answers from your aponorm Professional manual

Ask anything about the aponorm Professional. Answers come from this manual, with the pages they are based on.

Professional Maintenance Schedule

Remind me when maintenance is due
Every 2 years
Accuracy test

Test the device for accuracy every 2 years or after mechanical impact like dropping. Contact service to arrange.

Show in the manual (page 14)
When flat battery symbol appears
Replace batteries

Replace batteries immediately when the flat battery symbol flashes. Use 4 new AAA 1.5V batteries.

Show in the manual (page 12)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Professional?

Yes No

Frequently Asked Questions

A

It screens for atrial fibrillation which is a risk factor for stroke. The device analyzes pulse irregularity during measurement to detect this condition early. Early diagnosis allows for treatment to reduce stroke risk significantly according to the manual.

Is this answer helpful?

A

The device stores up to 99 measurement values for each of the two users. Once memory is full, the oldest value is overwritten. You can review all stored values using the memory button.

Is this answer helpful?

A

Yes, the monitor is tested for use in pregnancy and pre-eclampsia. If you detect unusual high readings, measure again after four hours. Consult your doctor if readings remain too high.

Is this answer helpful?

A

No, it is not required for basic use. However, the device can link to a PC using software to transfer data. A Mini-B USB cable is needed for this function.

Is this answer helpful?

A

The bars indicate if your blood pressure is optimum, elevated, too high, or dangerously high. The classification follows international guidelines like ESH and AHA protocols for home monitoring.

Is this answer helpful?

A

Use four 1.5 V size AAA batteries. Rechargeable NiMH types are also acceptable but must be removed for charging outside the device.

Is this answer helpful?

A

It is recommended to test accuracy every two years or after any mechanical impact like dropping the device. Contact customer service to arrange this test.

Is this answer helpful?

M: qwen/qwen3.5-flash-20260224

Advantages and Disadvantages

Advantages

  • AFIB detection screens for atrial fibrillation to prevent strokes.
  • Traffic light display indicates blood pressure status instantly.
  • Dual user memory supports storing data for two people.
  • Automatic multiple measurement mode increases reliability.
  • Five-year guarantee covers functional device defects.
VS

Disadvantages

  • Requires AAA batteries that must be replaced regularly.
  • Cuff size must match arm circumference precisely for accuracy.
  • Radio clock depends on signal availability for sync.
  • Not suitable for heart pacemakers users.
  • AFIB detection only activates in specific measurement mode.
M: qwen/qwen3.5-flash-20260224

Product Specification

Power Source

Battery powered (4x AAA Battery)

Measurement Type

Upper Arm, Fully Automatic

Cuff Circumference

8.66-16.54 inches

Analysis Data

Systole, Diastole, Pulse, Arrhythmia Detection, Risk Indicator, Rest Indicator

Memory Function

User Memory (for 2 Persons) 99 memory slots each

Display

Yes

Features

Date Display, Time Display, PC Interface (USB), Auto Power Off

Package Contents

Carrying Case, Blood Pressure Passport, Stand

M: qwen/qwen3.5-flash-20260224

Product Description

Understanding Health Monitoring

Taking control of your cardiovascular health starts with accurate monitoring. The Aponorm Professional device stands out as a premier choice for home management. Designed with precision engineering, this upper arm monitor ensures patients receive data that truly matters. Whether managing hypertension or tracking wellness, this equipment delivers consistent results.

Key Features for Reliable Data

One standout capability is the advanced AFIB detection technology. Atrial fibrillation often requires early intervention. The device analyzes pulse irregularity during measurements to screen for this condition. When used in AFIB/MAM mode, the device performs automatic multiple measurements to enhance reliability. This process accounts for natural fluctuations in blood pressure throughout the day. The user-friendly interface includes a color-coded traffic light display. This feature helps individuals quickly understand their readings without complex charts. Green indicates optimal levels, while red signals a dangerous situation requiring urgent attention. Storing data is seamless, with memory for two distinct users. This makes the device ideal for households sharing health responsibilities.

Ensuring Ease of Use

Setting up your unit is straightforward. It features a radio clock that synchronizes with the DCF77 signal for accurate timekeeping. If the signal is unavailable, manual settings are supported. For power, the unit operates on standard AAA batteries or an optional mains adapter. This flexibility ensures you can measure pressure anytime. Always refer to the official Aponorm Professional Manual for detailed setup instructions regarding cuff selection. The cuff size is critical for accuracy. Users must match the circumference of their upper arm to the correct cuff size to prevent measurement errors. The device compensates for user movement with specific indicators. If the arm moves during inflation, the system alerts the user. This minimizes false readings and builds trust.

Long-Term Reliability

Backed by a five-year guarantee, this device offers peace of mind regarding longevity. Clinical tests verify its accuracy against international standards. It is noted for reliability in pregnancy and pre-eclampsia screening under medical guidance. Regular accuracy testing every two years is recommended to maintain standards. By integrating these features, the monitor becomes a partner in health management. Consistent monitoring reduces stroke risks when combined with doctor guidance. The memory functions allow tracking trends over time. Remember to discuss unusual readings with your healthcare provider immediately.

Notes: Always follow safety guidelines. Remove batteries during long storage. Ensure proper cuff placement.

M: qwen/qwen3.5-flash-20260224

© Copyright 2026 Manual.ly