page

/ 18

Loading...
c3e9e9bee677b1c6137529da631794b97d4c page 4
aponorm
®
Professionell
aponorm
®
by
16
EN
1
START/STOP Button
2
Display
3
Cuff Socket
4
Mains Adapter Socket
5
Battery Compartment
6
Cuff
7
Cuff Connector
8
AFIB/MAM Switch
9
User Switch
10
Time Button
11
M-Button (Memory)
12
- «Backward» Button
13
+ «Forward» Button
14
Lock Switch
15
USB Port
Display
16
Date/Time
17
Systolic Value
18
Diastolic Value
19
Pulse Rate
20
Battery Display
21
Traffic Light Display
22
Stored Value
23
Pulse Indicator
24
Cuff Check Indicator
25
Atrial Fibrillation Indicator (AFIB)
26
AFIB/MAM Mode
27
Arm Movement Indicator
28
User Indicator
29
MAM Interval Time
30
Radio Clock
Dear Customer,
Your new aponorm
®
by microlife blood pressure monitor is a
reliable medical device for taking measurements on the upper
arm. It is simple to use, accurate and comes highly recommen
-
ded for blood pressure monitoring in your home. This device was
developed in collaboration with physicians and clinical tests
carried out proving its measurement accuracy to be of a very
high standard.*
aponorm
®
by microlife AFIB detection is the world’s leading
digital blood pressure measurement technology for the detection
of atrial fibrillation (AFIB) and hypertension. These are the two
top risk factors of getting a stroke or heart disease in the future.
It is important to detect AFIB and hypertension at an early stage,
even though you may not experience any symptoms. Appropriate
treatment will reduce your risk of suffering a stroke. For this
reason, it is recommended that you visit your doctor when the
device gives an AFIB signal during your blood pressure measu
-
rement. The AFIB algorithm of aponorm
®
by microlife has been
clinically investigated by several prominent clinical investigators
and showed that the device detects patients with AFIB at a
certainty of 97-100%.
1, 2
Type BF applied part
Read the instructions carefully before using this device.

Chat with your aponorm Professional manual using AI

Get instant AI answers from your aponorm Professional manual

Ask anything about the aponorm Professional. Answers come from this manual, with the pages they are based on.

Professional Maintenance Schedule

Remind me when maintenance is due
Every 2 years
Accuracy test

Test the device for accuracy every 2 years or after mechanical impact like dropping. Contact service to arrange.

Show in the manual (page 14)
When flat battery symbol appears
Replace batteries

Replace batteries immediately when the flat battery symbol flashes. Use 4 new AAA 1.5V batteries.

Show in the manual (page 12)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Professional?

Yes No

Frequently Asked Questions

A

It screens for atrial fibrillation which is a risk factor for stroke. The device analyzes pulse irregularity during measurement to detect this condition early. Early diagnosis allows for treatment to reduce stroke risk significantly according to the manual.

Is this answer helpful?

A

The device stores up to 99 measurement values for each of the two users. Once memory is full, the oldest value is overwritten. You can review all stored values using the memory button.

Is this answer helpful?

A

Yes, the monitor is tested for use in pregnancy and pre-eclampsia. If you detect unusual high readings, measure again after four hours. Consult your doctor if readings remain too high.

Is this answer helpful?

A

No, it is not required for basic use. However, the device can link to a PC using software to transfer data. A Mini-B USB cable is needed for this function.

Is this answer helpful?

A

The bars indicate if your blood pressure is optimum, elevated, too high, or dangerously high. The classification follows international guidelines like ESH and AHA protocols for home monitoring.

Is this answer helpful?

A

Use four 1.5 V size AAA batteries. Rechargeable NiMH types are also acceptable but must be removed for charging outside the device.

Is this answer helpful?

A

It is recommended to test accuracy every two years or after any mechanical impact like dropping the device. Contact customer service to arrange this test.

Is this answer helpful?

M: qwen/qwen3.5-flash-20260224

Advantages and Disadvantages

Advantages

  • AFIB detection screens for atrial fibrillation to prevent strokes.
  • Traffic light display indicates blood pressure status instantly.
  • Dual user memory supports storing data for two people.
  • Automatic multiple measurement mode increases reliability.
  • Five-year guarantee covers functional device defects.
VS

Disadvantages

  • Requires AAA batteries that must be replaced regularly.
  • Cuff size must match arm circumference precisely for accuracy.
  • Radio clock depends on signal availability for sync.
  • Not suitable for heart pacemakers users.
  • AFIB detection only activates in specific measurement mode.
M: qwen/qwen3.5-flash-20260224

Product Specification

Power Source

Battery powered (4x AAA Battery)

Measurement Type

Upper Arm, Fully Automatic

Cuff Circumference

8.66-16.54 inches

Analysis Data

Systole, Diastole, Pulse, Arrhythmia Detection, Risk Indicator, Rest Indicator

Memory Function

User Memory (for 2 Persons) 99 memory slots each

Display

Yes

Features

Date Display, Time Display, PC Interface (USB), Auto Power Off

Package Contents

Carrying Case, Blood Pressure Passport, Stand

M: qwen/qwen3.5-flash-20260224

Product Description

Understanding Health Monitoring

Taking control of your cardiovascular health starts with accurate monitoring. The Aponorm Professional device stands out as a premier choice for home management. Designed with precision engineering, this upper arm monitor ensures patients receive data that truly matters. Whether managing hypertension or tracking wellness, this equipment delivers consistent results.

Key Features for Reliable Data

One standout capability is the advanced AFIB detection technology. Atrial fibrillation often requires early intervention. The device analyzes pulse irregularity during measurements to screen for this condition. When used in AFIB/MAM mode, the device performs automatic multiple measurements to enhance reliability. This process accounts for natural fluctuations in blood pressure throughout the day. The user-friendly interface includes a color-coded traffic light display. This feature helps individuals quickly understand their readings without complex charts. Green indicates optimal levels, while red signals a dangerous situation requiring urgent attention. Storing data is seamless, with memory for two distinct users. This makes the device ideal for households sharing health responsibilities.

Ensuring Ease of Use

Setting up your unit is straightforward. It features a radio clock that synchronizes with the DCF77 signal for accurate timekeeping. If the signal is unavailable, manual settings are supported. For power, the unit operates on standard AAA batteries or an optional mains adapter. This flexibility ensures you can measure pressure anytime. Always refer to the official Aponorm Professional Manual for detailed setup instructions regarding cuff selection. The cuff size is critical for accuracy. Users must match the circumference of their upper arm to the correct cuff size to prevent measurement errors. The device compensates for user movement with specific indicators. If the arm moves during inflation, the system alerts the user. This minimizes false readings and builds trust.

Long-Term Reliability

Backed by a five-year guarantee, this device offers peace of mind regarding longevity. Clinical tests verify its accuracy against international standards. It is noted for reliability in pregnancy and pre-eclampsia screening under medical guidance. Regular accuracy testing every two years is recommended to maintain standards. By integrating these features, the monitor becomes a partner in health management. Consistent monitoring reduces stroke risks when combined with doctor guidance. The memory functions allow tracking trends over time. Remember to discuss unusual readings with your healthcare provider immediately.

Notes: Always follow safety guidelines. Remove batteries during long storage. Ensure proper cuff placement.