Manual.ly Logo

APC Smart-UPS SRT 1000VA RM Manual

0.0 · 0 Ratings

PDF manual · 29 Pages

English

M: qwen/qwen3.5-flash-20260224
page

/ 29

Loading...
40fd5dcf7174c8fbd8de2d7facd45d8bfa3e page 1
Operation Manual
Smart-UPS
™
On-Line SRT
Uninterruptible Power Supply
SRT1000UXI-LI
SRT1000UXI-NCLI
SRT1500UXI-LI
SRT1500UXI-NCLI
220/230/240 Vac
Tower/Rack-Mount 2U
For Professional Business Applications – Not For Consumer Use

Chat with your APC Smart-UPS SRT 1000VA RM manual using AI

Get instant AI answers from your APC Smart-UPS SRT 1000VA RM manual

Ask anything about the APC Smart-UPS SRT 1000VA RM. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend Smart-UPS SRT 1000VA RM?

Yes No

Frequently Asked Questions

A

The Lithium Ion batteries typically last for five to eight years. Environmental factors like heat can shorten this life. Replacement is necessary when the UPS indicates it.

Is this answer helpful?

A

Yes, the system recognizes up to five battery packs. Each added pack extends runtime but requires additional recharge time for full capacity.

Is this answer helpful?

A

The product is warranted for five years from the date of purchase. Registration must occur within ten days of purchase for full coverage.

Is this answer helpful?

A

Battery health is monitored during self-tests and operating on battery. The display interface shows charge status and replacement notifications.

Is this answer helpful?

A

Yes, the UPS supports connecting up to five battery packs. This provides extended runtime during power outages.

Is this answer helpful?

A

A Site Wiring Fault alert indicates the input AC mains connection has reversed phase and neutral. It must be corrected or acknowledged.

Is this answer helpful?

A

Press and hold the Power button until a beep is heard. Select Turn ON with NO AC to start using battery power without mains input.

Is this answer helpful?

M: qwen/qwen3.5-flash-20260224

Advantages and Disadvantages

Advantages

  • Lithium Ion battery technology ensures longer lifespan and faster recharge compared to standard lead-acid units.
  • Online double-conversion design provides clean power protection against all form of electrical disturbances.
  • Flexible installation supports both tower and rack-mount two U configurations for various space constraints.
  • Network management slot allows remote monitoring and control via web interface or SNMP protocols.
VS

Disadvantages

  • Unit weight is heavy which may require additional rack support considerations during installation.
  • Higher initial cost compared to standby UPS systems due to advanced online architecture.
  • Replacement battery modules are specific and sourced only through authorized dealers.
M: qwen/qwen3.5-flash-20260224

Product Specification

Type

Rackmount

Classification

VFI (On-Line)

Apparent Power

1000VA

Real Power

900W

Voltage

230V

Input

1x C14

Outputs

8x C13

Interfaces

USB-A, serial (RJ-45)

Data Line Protection

N/A

Weight

38.60 lbs

Dimensions (WxHxD)

17.01x3.35x23.23 inches

Rack Units

2U

Features

LCD, incl. UPS network management card (1x LAN, 2x USB-A, 2x Sensors), incl. Li-Ion battery, IP20

Manufacturer Warranty

5 years

M: qwen/qwen3.5-flash-20260224

Product Description

Protect Your Business Infrastructure

The APC Smart-UPS SRT 1000VA RM 230V with Network Card and Li-Ion Battery USB/serial Manual requires careful setup for optimal performance in data centers. This high-performance uninterruptible power supply protects against blackouts, brownouts, and surges. By using Online technology, it isolates equipment from dirty power. The Lithium Ion batteries reduce maintenance needs compared to traditional VRLA types. They maintain charge better over time and provide consistent discharge rates up to two kilowatts.

Connectivity options include a Network Management Card slot. This enables remote monitoring via email or SNMP. Serial communication allows direct connection to servers. The front panel display shows load percentage, voltage, and frequency. Advanced menus allow technicians to configure alarm thresholds and output settings. Controllable outlets let you shut down non-critical systems during low battery to preserve power for key servers.

Safety is emphasized throughout the documentation. Warning labels indicate electrical hazards. Proper lifting techniques are required due to unit weight exceeding thirty pounds. Battery packs must be disconnected before servicing to prevent shock. The product complies with EMC directives regarding cord lengths in Europe. Grounding conductors must match supply wires.

Warranty registration is required within ten days for full coverage. Service requires a Returned Material Authorization number. Shipping instructions forbid foam beads to prevent damage. Support is available globally via phone or web. Firmware upgrades can be installed during operation but may temporarily reduce protection. Battery replacement should be scheduled based on the replace notification timer defaulting to 180 days before end of life.

Proper ventilation prevents overheating which degrades internal components. The ambient temperature range is zero to forty degrees Celsius. Humidity must remain between zero and ninety-five percent without condensation. These specifications ensure longevity in standard data center environments. This unit is designed for professional business applications and is not intended for consumer use. Installation requires a qualified electrician to adhere to national electrical codes. Changes not approved by APC could void the warranty. The UPS input ground conductor must be bonded to protective earth at the service panel. If input power comes from a separately derived system, bonding must occur at the supply transformer. The battery pack will disconnect to protect cells if charge current exceeds 12 Amperes. Around zero degrees Celsius, charging current limits to 400 mA. Users should remove conductive jewelry before servicing batteries to avoid burns. Do not dispose of batteries in fire as they could explode. The UPS will recognize up to five battery packs for extended runtime. Additional recharge time is required for each added pack. Model numbers are on the rear panel label. Recycle package materials or save them for future use. The Emergency Power Off function allows users to immediately disconnect connected equipment from mains power. The UPS must be restarted manually via the front panel button after EPO activation. Wire types CL2P and CL2R are recommended for EPO installations. Normally or normally open contacts can be used at terminal block pins one and two or two and three. The EPO circuit is Safety Extra Low Voltage and must not exceed low current ratings. Network management utility CD is included for IP configuration. Language options include English, French, and Spanish. Default settings can be reset to factory values from the main menu. The Setup Wizard guides users through initial configuration prompts. Output voltage settings depend on the specific model region. Green mode sends mains power directly but offers slight interruption during switching. Bypass mode operates when input voltage is within configured limits. Automatic self-tests are programmed based on startup or regular intervals.

Notes

  • Always connect to a grounded outlet.
  • Recycle used batteries responsibly.
  • Firmware updates may reduce protection temporarily.
M: qwen/qwen3.5-flash-20260224

© Copyright 2026 Manual.ly