Important Safety Instructions
Smart-UPS SMTL 2200/3000 RMI2UC/RMI2UCNC
EN TME20822 – 08/2023
Battery safety
• Servicing of batteries should be performed or supervised by personnel
knowledgeable about batteries and the required precautions.
• Contact APC by Schneider Electric Customer Support to determine the age of the
installed RBMs.
• The battery typically lasts for five to ten years. Environmental factors impact battery
life. Elevated ambient temperatures, poor quality utility power, and frequent short
duration discharges will shorten battery life.
• For longest battery performance, the ambient temperature should be maintained
between 68 and 77 °F (20 and 25 °C).
• Replace the battery module once the battery module have reached the end of their
service life even if the UPS has not indicated that battery replacement is necessary.
• The batteries are user replaceable. Under normal operating conditions, there is no
need for replacement. If attempting to replace batteries,
– Use only APC by Schneider Electric battery modules.
– Do not use third-party batteries as replacements.
• APC by Schneider Electric uses Lithium Ion batteries. Under normal use and
handling, there is no contact with the internal components of the battery.
• Do not drive nails into the battery pack.
• Do not strike the battery pack with a hammer.
• Do not stand on the battery pack.
• Do not short circuit battery pack.
• Do not place or use the battery pack near heat or fire.
• Do not use a dropped, damaged or deformed battery pack.
• Do not use the battery pack to power other equipment.
WARNING
RISK OF CHEMICAL HAZARD AND EXCESSIVE HEAT
• Replace the battery at least every 10 years, or at the end of its service life, which
ever is earlier.
• Replace the battery immediately when the UPS indicates battery replacement is
necessary.
• Replace batteries with the same number and type of batteries as originally
installed in the equipment.
• Replace the battery immediately when the UPS indicates a battery
over-temperature condition or UPS internal over-temperature. Power off the
UPS, unplug it from the AC input, and disconnect the batteries.
• Do not operate the UPS until the batteries have been replaced.
Failure to follow these instructions can result in death or serious injury.

Chat with your APC Smart-UPS Lithium-Ion 2200VA manual using AI

Get instant AI answers from your APC Smart-UPS Lithium-Ion 2200VA manual

Ask anything about the APC Smart-UPS Lithium-Ion 2200VA. Answers come from this manual, with the pages they are based on.

Smart-UPS Lithium-Ion 2200VA Maintenance Schedule

Every 14 days
Perform automatic self-test

The UPS performs an automatic self-test upon startup and every 14 days thereafter. This setting can be configured in the extended menus.

Show in the manual (page 23)
Every 10 years
Replace battery module

Replace the battery module at least every 10 years or at the end of its useful life, whichever occurs first, even if no warning is displayed.

M: QW-35-FL

Ask a Question

0/1000

Do you recommend Smart-UPS Lithium-Ion 2200VA?

Yes No

Frequently Asked Questions

A

Lithium-Ion modules typically last five to ten years depending on environmental factors and usage conditions.

Is this answer helpful?

A

Yes, use the SmartConnect Ethernet port to monitor status via web portal from any internet connection.

Is this answer helpful?

A

No, a qualified electrician must handle wiring to meet safety codes and ensure proper grounding.

Is this answer helpful?

A

Yes, PowerChute software supports standard operating systems including Linux servers for automated management.

Is this answer helpful?

A

The unit comes with a five-year warranty from the date of purchase for original buyers.

Is this answer helpful?

A

For best results use only approved APC replacement battery modules to maintain warranty and safety.

Is this answer helpful?

A

Use the included Ethernet cable to connect the SmartConnect port to your network switch.

Is this answer helpful?

M: qwen/qwen3.5-flash-20260224

Advantages and Disadvantages

Advantages

  • Five-year warranty provides excellent long-term coverage for business continuity needs.
  • Lithium-Ion batteries offer a lifespan up to ten years reducing replacement frequency significantly.
  • SmartConnect enables remote monitoring of power status via Ethernet connection securely.
  • Rackmount design fits standard server racks saving valuable floor space efficiently.
  • Hot-swappable modules allow quick maintenance with minimal downtime interruption.
VS

Disadvantages

  • Heavy weight requires safe lifting techniques during installation and transport carefully.
  • Lithium-Ion shipping regulations require special packaging for courier services globally.
  • Qualified electrician must wire the unit to ensure grounding safety compliance always.
  • Weight restrictions may limit placement options for smaller data center racks safely.
M: qwen/qwen3.5-flash-20260224

Product Specification

Type

Rackmount

Classification

VI (Line-Interactive)

Apparent Power

2200VA

Active Power

1980W

Voltage

230V

Input

1x C20

Outputs

8x C13, 1x C19

Interfaces

USB, LAN (SmartConnect), Serial (RJ-45)

Data Line Protection

N/A

Runtime

15.5 min (50%), 7.5 min (100%)

Charge Time

2 h

Weight

73.41 lbs

Dimensions (WxHxD)

17.01 x 3.39 x 26.89 in

Rack Units

2U

Features

LCD

Manufacturer Warranty

5 years

M: qwen/qwen3.5-flash-20260224

Product Description

Protecting Your Critical Infrastructure

In today's fast-paced digital landscape, uninterrupted power is absolutely non-negotiable for maintaining business continuity. The APC Smart-UPS Lithium-Ion 2200VA offers robust protection for your network equipment and servers in modern data centers. Designed specifically for 2U rackmount environments, this unit ensures your business operations continue smoothly during sudden power fluctuations. It features advanced Lithium-Ion technology which provides a significantly longer lifecycle, typically lasting between five to ten years compared to traditional lead-acid batteries found in older units. This technology significantly minimizes maintenance costs over the total lifespan of the hardware. The compact design allows for maximum efficiency within server cabinets. This device meets high industry standards.

Advanced Connectivity and Monitoring

Stay informed about your power status from anywhere in the world. The integrated SmartConnect Ethernet port allows remote monitoring of the unit's health via secure web portals. You can track current load levels, battery charging status, and receive automatic notifications about events or available firmware updates. This feature minimizes downtime by enabling proactive maintenance before critical issues escalate into complete outages. The system also supports Modbus TCP/IP protocols for integration into broader building management systems for centralized oversight. Network management card slots offer additional connectivity options for advanced users.

Easy Installation and Management

Setting up the system is straightforward with the included professional rackmount hardware components provided. The front panel LCD display guides you through initial configuration with a user-friendly setup assistant for language and sensitivity settings. For deeper control and automated responses, PowerChute software facilitates automatic system shutdowns to prevent data loss during extended outages. Serial and USB ports provide local management options for administrators who prefer direct connections. Controlled outlet groups allow you to shut down non-essential peripherals to extend runtime during battery operation effectively. Firmware updates can be managed directly through the front panel interface.

Safety and Reliability

Constructed with comprehensive safety in mind, this unit includes strict grounding requirements to prevent significant electrical hazards during operation. The internal Lithium-Ion battery modules are hot-swappable, which reduces downtime significantly during maintenance procedures. Always adhere to national electrical codes and hire qualified personnel for installation tasks to ensure safety compliance is met. The system includes a comprehensive five-year warranty, ensuring long-term reliability and support from Schneider Electric after purchase. Be aware of weight restrictions during transport, as the unit is quite heavy once fully installed with batteries included. Emergency Power Off options are available to disconnect power instantly for safety.