User Guide
Easy Rack Power Distribution Unit
Metered 1P
EPDU1016M
EPDU1116M
EPDU1132M
EPDU1016M-GB
EPDU1116M-GB12
EPDU1132M-GB16
EPDU1132M-GB24
990-6265A-001
Publication Date: September 2020

Chat with your APC EPDU1016M manual using AI

Get instant AI answers from your APC EPDU1016M manual

Ask anything about the APC EPDU1016M. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend EPDU1016M?

Yes No

Frequently Asked Questions

A

Connect the device to your network and enter its IP address into a supported browser like Chrome or Firefox. Use the default username and password 'apc' to log in as a Super User.

Is this answer helpful?

A

Yes, the Easy PDU includes a dedicated port for a temperature and humidity sensor. The web interface displays real-time values collected from this external sensor.

Is this answer helpful?

A

If you lose connectivity, the LCD display will continue to flash periodically, and the buzzer will sound if an alarm condition is triggered locally.

Is this answer helpful?

A

No, Modbus TCP is disabled by default. You must enable it through the Web User Interface and reboot the device for changes to take effect.

Is this answer helpful?

A

Press and hold the Reset button on the front panel for at least 10 seconds. This resets network, SNMP, and user settings but preserves the date, time, and energy logs.

Is this answer helpful?

A

No, there is no Real-Time Clock battery. You must configure an SNTP server during the first login to ensure the system time remains accurate after power cycles.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Real-time remote monitoring of power, voltage, current, and energy metrics
  • Configurable alarm thresholds prevent circuit overloads and equipment damage
  • Supports multiple management interfaces including Web UI, SNMP, and Modbus TCP
  • Robust security features with SNMPv3 encryption and role-based user access
  • Integrated temperature and humidity sensing for environmental awareness
VS

Disadvantages

  • No internal Real-Time Clock battery requires SNTP server configuration for time accuracy
  • Default community name 'public' cannot be changed in SNMP settings
  • Modbus TCP support is disabled by default and requires specific firmware versions
  • Self-signed certificates may trigger browser warnings without CA installation
  • Event log is limited to the most recent 100 entries
M: QW-35-FL

Product Specification

Outputs

18x C13, 3x C19

Input

1x C13 (16A)

Input Voltage

230V

Power

3680W (max.)

Cable Length

3m

Dimensions (WxDxH)

35.51x2.44x1.73in

Weight

5.51lbs

Features

rackmount capable

Manufacturer Warranty

one year

M: QW-35-FL

Product Description

APC Easy PDU Metered 0HE 16A: Power Management Simplified

The APC Easy PDU Metered 0HE 16A represents a significant leap in data center power management, designed to provide real-time visibility and control over your critical IT infrastructure. As a network-manageable device, this unit allows administrators to monitor connected loads remotely, ensuring optimal performance and preventing costly downtime. Whether you are managing a small server room or a large enterprise facility, the Easy PDU offers the tools necessary to maintain electrical efficiency and safety.

One of the standout features of this product is its comprehensive monitoring capabilities. Users can track device power, apparent power, power factor, and energy consumption across phases. The integrated temperature and humidity sensors provide environmental context, allowing for proactive cooling adjustments before equipment overheating occurs. With configurable alarm thresholds, the system warns you of potential circuit overloads via email traps, SNMP notifications, or local buzzer alerts, giving you the chance to intervene before a trip occurs.

Setting up the APC Easy PDU Metered 0HE 16A is straightforward. Once installed, it defaults to DHCP for easy network integration, though static IP configuration is fully supported for specialized environments. Accessing the device is intuitive through a web-based user interface compatible with major browsers like Chrome, Firefox, and Internet Explorer. This interface serves as a central hub where you can manage users, configure SNMP settings, upgrade firmware, and view detailed event logs. The ability to reset energy statistics helps in tracking usage cycles accurately, while Modbus TCP support (on specific firmware versions) enables deeper integration with building management systems.

Security is paramount in modern data centers, and this unit delivers robust protection. It supports multiple authentication protocols including SHA and MD5 for SNMPv3, ensuring that only authorized personnel can alter settings or access sensitive data. The distinction between Super User and General User roles allows for granular permission control, ensuring that day-to-day monitoring does not compromise system integrity. By keeping firmware updated, users ensure they have the latest bug fixes and feature enhancements available directly from the manufacturer.

Key Benefits

This solution eliminates guesswork in power distribution. Instead of relying on manual checks, you gain instant access to voltage, current, and frequency data. The device also simplifies compliance and auditing by maintaining a log of the most recent 100 events, which can be downloaded for review. The inclusion of SNTP synchronization ensures accurate time-stamping for all logged events, which is crucial for troubleshooting and forensic analysis.

Important Notes

  • Always verify that your specific model supports Modbus TCP before attempting configuration.
  • A Real-Time Clock battery is not included; an SNTP server must be configured to maintain accurate time after power cycles.
  • The default credentials are 'apc' for both username and password; these should be changed immediately upon initial setup.
  • Firmware upgrades require a system reboot to complete successfully.
  • Radio Frequency Interference testing is not performed, so usage may be restricted in certain regions like Japan or North America depending on local laws.