SAFETY INSTRUCTION
READ THE SAFETY INSTRUCTIONS BEFORE STARTING THE INSTALLATION
• Not suitable for children under 6 years. (contains small parts which could be swallowed).
• Do not run any cooling components without ensuring that cooling liquid is flowing through the cooling system. Coolers operated without coolant can become
very hot. Caution: Burn Hazard!
• Coolers that have no coolant flowing through them can destroy the computer hardware. When switching on the hardware, always make sure that the pump
is working.
• Please note when tightening the connectors or fittings, no tools such as screwdrivers, pliers, or wrenches should be used. All plastic products or metal
threaded connections, which are linked with plastic parts, are easily over-loaded with tools. Cracking or other damages incurred in this way, as well as damage
from leaking coolant, are not covered under the warranty!
• Use only connectors with a sealing o-ring. When using a sealing ring a firm tightening with the hand is enough. Your instruction manual will clearly refer to
the use of tools in exceptional cases.
• If you have not done so yet, please check your hardware and cooling system (tightness, pump function and fans). This will minimize time spent searching for
possible problems. ALPHACOOL INTERNATIONAL GMBH accepts no liability on the warranty of the manufacturer of the electronic components. The assembly
of the cooling system takes place at your own risk.
• The screws should not be tightened too firmly. If you tighten the screws excessively, the knurled nuts can loosen and the cooler´s uniform pressure is no
longer guaranteed.
• Fasten the connections of your choice to the cooler. Do not use tools such as wrenches for fastening the connections. Connectors with 8mm long threads
may stop the flow.
• We recommend a tightness test before assembling/installing the cooler. The water pressure in the water cooling loop can be at a maximum of 0.8 bar. DO
NOT use tools on the connectors.
• Ensure that the cooler is touching all components to be cooled through thermal grease and thermal pads.
• Only use distilled water or ALPHACOOL CAPE KELVIN CATCHER in your cooling circuit. Damage caused by unsuitable coolant is not covered by the warranty!
Specified normal operation
All ALPHACOOL INTERNATIONAL GMBH cooling components are constructed and licensed for ALPHACOOL INTERNATIONAL GMBH computer construction
parts. The warranty expires in case of misuse.
Warranty
1. Data, designs, illustrations, technical data, weight, measurement and specifications, contained in folders, catalogues, circulars, announcements or price lists,
have a purely informative character. We do not undertake warranty for the correctness of these data. As to the kind and the range of delivery, the data
contained in the order and confirmation of order alone are decisive.
2. If there is a lack of warrantor, you are entitled, on the basis of the legal regulations to require subsequent delivery, to withdraw from the contract or reduce
the purchase price. If you are a consumer, the limitation period of warranty claims for the supplied commodity amounts to two years starting from receipt of
goods (§ 13 BGB). If you are an entrepreneur, in accordance with legal conditions the limitation period amounts to only one year (§ 14 BGB).
3. The warranty claim is valid only in combination with the original invoice, the sales slip or an ALPHACOOL confirmation on warranty claim.
4. It is ALPHACOOL INTERNATIONAL GMBHs own discretionary authority to replace or repair the defective product or defective component. The replaced
product or component changes into property of ALPHACOOL INTERNATIONAL GMBH.
5. All warranty claims are accomplished by ALPHACOOL INTERNATIONAL GMBH or its authorized dealers. If the repair is carried out by a non-authorized or
assigned person, ALPHACOOL INTERNATIONAL GMBH does not take over either costs or liability, unless the repair has been previously agreed upon with
ALPHACOOL INTERNATIONAL GMBH.
6. All costs resulting from refitting of the products are not taken over by ALPHACOOL INTERNATIONAL GMBH.
7. ALPHACOOL INTERNATIONAL GMBHs warranty excludes the following points:
7.1. Regular controls maintenance and repair or the replacement of parts subject to regular wear and tear.
7.2. Improper manipulation or defects caused by incorrect installation.
7.3. Damages caused by storm, water, fire, overvoltage, acts of God, war, incorrect connection to the net, insufficient or incorrect ventilation or
other reasons over which ALPHACOOL INTERNATIONAL GMBH has no influence.
7.4. Damages resulting from transportation or improper packaging.
8. Consumer´s rights are valid in the respective country; demands made to the salesman, as explained and laid down in the sales contract, will not be covered
by this warranty. ALPHACOOL INTERNATIONAL GMBH, its Branch Office and Distributors, are not responsible for direct or indirect damage or losses, as far as
the
compelling legal regulations do not oppose it.
9. ALPHACOOL INTERNATIONAL GMBH does not take over the warranty of the manufacturer of the electronic construction units and components. The
assembly of the cooler takes place at your own risk.
Contact an authorized waste management company in your country. A
waste removal with the municipal waste (unsorted garbage) or similar
mechanisms for the collection of local wastes is not permissible!

Chat with your Alphacool ES Reservoir 1U manual using AI

Get instant AI answers from your Alphacool ES Reservoir 1U manual

Ask anything about the Alphacool ES Reservoir 1U. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend ES Reservoir 1U?

Yes No

Frequently Asked Questions

A

It is designed for integration with a compatible DDC pump. The pump is mounted to the reservoir using an O-ring, creating a compact combined unit.

Is this answer helpful?

A

Yes. It can operate as a standalone reservoir. Connect the required tubing ports and seal every unused threaded opening with the supplied screw plugs.

Is this answer helpful?

A

It can be attached to a radiator with retaining plates, installed on a fan, mounted with brackets, or secured to a suitable flat surface using the included double-sided Velcro.

Is this answer helpful?

A

Use distilled water, osmosis-filtered water, or compatible clear Alphacool coolant. UV coolant and unsuitable fluids should be avoided because they can damage the cooling loop.

Is this answer helpful?

A

Use fittings with sealing O-rings and tighten them firmly by hand. Do not use pliers, wrenches, or similar tools on fittings connected to plastic parts.

Is this answer helpful?

A

The liquid level falls as coolant displaces trapped air from the loop. Keep filling the reservoir until the level stops dropping so the pump does not run dry.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Dedicated DDC pump mounting creates a compact reservoir and pump assembly.
  • Multiple threaded ports support flexible tubing, filling, draining, and loop routing.
  • Can be mounted with a radiator, independently, on a fan, or with double-sided Velcro.
  • Includes plugs, brackets, hose holder, screws, and a two-piece radiator connection.
VS

Disadvantages

  • DDC pump installation details are provided separately and require compatible hardware.
  • Incorrect coolant, overtightened fittings, or dry operation can cause damage not covered by warranty.
  • Maximum recommended loop pressure is 0.8 bar.
  • Some 8 mm threaded fittings may restrict coolant flow.
M: gpt-5.6-terra

Product Specification

Type

Reservoir for pump mounting

Material

POM

Connections

G1/4"

Pump

N/A

Color

black (matte)

M: gpt-5.6-terra

Product Description

Alphacool ES Reservoir DDC Manual: Flexible Loop Management for Compact Builds

The Alphacool ES Reservoir DDC is a versatile reservoir solution designed for PC water-cooling loops built around a DDC pump. Its modular layout supports several installation approaches, making it suitable for users who need a clean coolant path in rackmount, workstation, server, or custom desktop systems. The unit can be paired directly with a compatible radiator, mounted independently, or positioned on a fan, helping builders adapt the loop to available space.

Designed for DDC Pump Integration

A core advantage of this reservoir is its dedicated DDC pump mounting arrangement. The pump attaches to the reservoir with an O-ring, creating a compact pump-and-reservoir assembly that can simplify tubing runs and reduce the number of separate mounting points. The pump-specific installation should be completed carefully, with all fittings tightened by hand where sealing O-rings are used.

The reservoir includes numerous threaded ports, giving builders flexibility when selecting inlet, outlet, fill, and drain positions. Unused ports can be sealed with the included screw plugs. This arrangement is useful when planning a loop around limited chassis clearance or when routing tubing around radiators, graphics cards, and power supplies.

Multiple Mounting Options

The Alphacool ES Reservoir DDC can be integrated with a radiator through a two-piece double nipple connection. Retaining plates secure the reservoir and radiator into a stable assembly, while alternative brackets and a hose holder provide further layout choices. For standalone use, the reservoir can be mounted without a radiator and connected directly to the rest of the cooling loop.

It can also be attached to a fan. When screw mounting is not practical, double-sided Velcro offers an alternative for securing the reservoir to a suitable flat surface. These options make the product especially helpful for builders who want to optimize internal space without sacrificing service access.

Filling and Safe Operation

Fill the loop through the upper fill port with a funnel or small beaker, after confirming that all other openings are sealed. During the first startup, coolant level will drop as air is displaced from the loop. Continue topping up the reservoir until the level remains stable, preventing the pump from running dry.

For reliable operation, use distilled or osmosis-filtered water, or a compatible clear Alphacool coolant. A leak test is recommended before powering PC hardware, and loop pressure should not exceed 0.8 bar. Avoid UV coolant and do not use tools to overtighten fittings connected to plastic parts.

Notes

  • Verify pump operation before starting the computer.
  • Use fittings with sealing O-rings and tighten them by hand.
  • Check for leaks before final installation.
  • Keep coolant flowing at all times to protect the pump and hardware.