I. Shoulder belt for easy transport and use: The compressor may
be conveniently carried using the shoulder belt.
– Ifthemetalringshavenotalreadybeenfitted,insertthetwo
rings in the two holes in the ends of the aluminium handle (as
shown in Figure 7a).
– To fit the belt to the compressor: attach the shoulder strap by
inserting the snap hooks into the metal rings on the ends of the
handle (as shown in Figure 7b).
J. Strip attach/detach: In case the compressor is fitted with a
Velcro®strip,usethisstriptosecureanair-operatedtool(e.g.:
nailer) or a PVC extension pipe to the body of the compressor (as
shown in Figures 6a-6b).
K. Storage box for accessories.
3. SCOPE OF USE
The compressor is designed for generating compressed air for tools
operated by compressed air.
Please note that our equipment has not been designed for use
in commercial, trade or industrial applications. Our warranty will
be voided if themachine is used incommercial, tradeor industrial
businesses or for equivalent purposes.
The machine is to be used only for its prescribed purpose. Any other
use is deemed to be a case of misuse. The user/operator and not
themanufacturerwillbeliableforanydamageorinjuriesofanykind
caused as a result of this.
4. ELECTRICAL GROUNDING INSTRUCTIONS
This product should be electrically grounded. In the event of an
electricalshortcircuit,groundingreducestheriskofelectricalshock
by providing an escape wire for electrical current. This product is
equipped with a cord having a grounding wire with an appropriate
grounding plug. The plug must be plugged into an outlet that is
properly installed and grounded in accordance with all local codes and
ordinances.
4.1 Connection of the mains plug
Important!
The wires in the mains lead fitted to this product are coloured in
accordance with the code shown in pic. 9.
● The3pinplugmustcomplytoBS1363/A.
● FusemustcomplytoBS1362.
If for any reason the 13 amp plug fitted to this product requires
replacement it must be wired in accordance with the following
instruction:
Do not connect the brown (live) or blue (neutral) to the earth pin marked
‘E’ on the 3 pin plug.
Connect the Blue wire to the terminal marked Neutral (N). Connect
the Brown wire to the terminal marked Live (L). Connect the Yellow
&GreenwiretotheterminalmarkedEarth(E).Ensurethattheouter
insulation is gripped by the cord grip and that the wires are not trapped
when replacing the plug cover. The mains lead on this product is fitted
with a 13 amp (BS1363/A) plug.A 13 amp (BS1362) fuse must be
fitted in the plug.
If in doubt consult a qualified electrician
There are no user serviceable parts inside this product except those
referred to in the manual. Always refer servicing to qualified service
personnel. Never remove any part of the casing unless qualified to do
so; this unit contains dangerous voltages.
Warning!
For your protection if this product is to be used outdoors it should not
be exposed to rain or used in damp locations. Do not place the product
ondampsurfaces,useaworkbenchifavailable.Foraddedprotection
use a suitable residual current device (R.C.D.) at the socket outlet.
Note: If the mains cable requires replacing it must be replaced with
an identical one and fitted by a qualified person.
5. PRE-START PROCEDURES
● Examine the machine for signs of transport damage. Report
any damage immediately to the company which delivered the
compressor.
● Verify that the tanks have been drained and are clear of any
moisture or dirt.
● Thecompressorshouldbesetupneartheworkingconsumer.
● Avoidlongairlinesandlongsupplylines(extensions).
● Makesuretheintakeairisdryanddust-free.
● Donotsetupthecompressorindamporwetrooms.
● Thecompressor may onlybeusedin suitable rooms(withgood
ventilation and an ambient temperature from +5°C to +40°C). There
mustbenodust,acids,vapours,explosivegasesorinflammable
gases in the room.
● Thecompressorisdesignedtobeusedindryrooms.Itisprohibited
to use the compressor in areas where work is conducted with
sprayed water.
6. OPERATION INSTRUCTIONS
6.1 Start-Up Procedures
1. Verify that the On/Off switch is in the Off position.
2. Verifythatthetankairpressureisat0PSI.
3. Attach the air hose to the discharge line.
4. Plug the unit into a properly grounded outlet.
5. Push the On/Off switch to On. The On/Off switch will light-up to
indicate the compressor is on. The compressor will automatically
cycle on and off to keep the tank pressure maintained .
6. Adjust the pressure regulator to the proper pressure setting
required for the air tool.
6.2 Shut-Off Procedures
1. Push in the On/Off switch to the Off position.
7. CLEANING AND MAINTENANCE
Warning!
Pull the power plug before doing any cleaning and maintenance
work on the appliance.
Warning!
Wait until the compressor has completely cooled down. Risk of
burns!
Warning!
Always depressurize the tank before carrying out any cleaning
and maintenance work.
7.1 Cleaning
●Keepthesafetydevicesfreeofdirtanddustasfaraspossible.Wipe
the equipment with a clean cloth or blow it with compressed air at
low pressure.
●Werecommendthatyoucleantheapplianceimmediatelyafteryou
use it.
●Cleantheapplianceregularlywithadampclothandsomesoftsoap.
Do not use cleaning agents or solvents; these may be aggressive to
theplasticpartsintheappliance.Ensurethatnowatercangetinto
the interior of the appliance.
●You must disconnect the hose and any spraying tools from the
compressor before cleaning. Do not clean the compressor with
water,solventsorthelike.
7.2 Draining tank
The condensation water must be drained off each day by opening the
drainvalve(ref.E)(onthebottomofthepressurevessel).
1. Verify that the compressor is turned Off.
2. Holdingthehandle,tiltthecompressortowardthedrainvalveso
that they are positioned at the bottom of the tank.
3. Turn the drain valve to open the valve.
4. Keep the compressor tilted until all moisture has been removed.
Warning!
The condensation water from the pressure vessel will contain
residual oil. Dispose of the condensation water in an environmentally
compatible manner at the appropriate collection point.

Chat with your Aerotec Airliner 5 Go manual using AI

Get instant AI answers from your Aerotec Airliner 5 Go manual

Ask anything about the Aerotec Airliner 5 Go. Answers come from this manual, with the pages they are based on.

Airliner 5 Go Maintenance Schedule

Daily
Drain tank condensation water

Open the drain valve daily to remove moisture from the tank. Tilt the compressor to ensure all water is removed.

Every few days
Clean safety devices

Keep safety devices free of dust and dirt by wiping with a clean cloth or blowing with low-pressure air.

Regularly
Clean appliance exterior

Clean regularly with a damp cloth and soft soap. Do not use solvents or wash with water.

Show in the manual (page 11)
Occasionally
Test safety valve

Actuate the safety valve occasionally by pulling the ring until air releases to ensure it functions correctly.

Show in the manual (page 12)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Airliner 5 Go?

Yes No
0
User Pic

Klaus W

7 months ago

Is the noise level from this compressor manageable in a typical garage?

0
User Pic

Manual.ly

7 months ago

The compressor uses an oil-free motor which is known to be louder than oil-lubricated models. While compact and powerful at 10 bar, users report higher volume during operation. It works well for inflating tires but ear protection may be needed for longer tasks. Overall performance is solid despite the noise.

M: qwen/qwen3.5-flash-20260224
M: qwen/qwen3.5-flash-20260224

Frequently Asked Questions

A

This compressor is designed for intermittent operation with a duty cycle of no more than 15 percent within one hour. Operating it beyond this limit may cause overheating and trigger the thermal protection cutout automatically. Always allow the motor to cool down before restarting if it trips due to high temperature.

Is this answer helpful?

A

No, the warranty is void if used in commercial, trade, or industrial applications. It is designed strictly for personal and DIY tasks. Industrial use may result in damage not covered by warranty. The manufacturer assumes no liability for damages arising from misuse in professional environments.

Is this answer helpful?

A

You must drain the condensation water daily to prevent rust inside the tank. Open the ball valve at the bottom of the pressure vessel to release moisture. Ensure the compressor is switched off before draining. Dispose of the condensate responsibly as it may contain oil residues.

Is this answer helpful?

A

Yes, the Aerotec Airliner 5 GO is an oil-free compressor. This means you will not get oil contamination in your air lines or tools. It is ideal for painting and pneumatic tools where oil mist could cause issues or damage sensitive equipment.

Is this answer helpful?

A

If it stops, check for overheating and let the unit cool down. Ensure all connections are secure and the ventilation is adequate. If the safety valve activates, there may be a pressure switch failure. Contact an authorized service center for repairs do not attempt to fix internal electrical components yourself.

Is this answer helpful?

M: qwen/qwen3.5-flash-20260224

Advantages and Disadvantages

Advantages

  • Oil-free design ensures clean air output without oil contamination for tools.
  • Automatic start and stop function maintains steady pressure in the tank independently.
  • Safety valve prevents over-pressurization to protect the air tank from explosion.
  • Portable design includes a handle and shoulder belt for easy transport to work sites.
VS

Disadvantages

  • Strict duty cycle limit of 15 percent per hour prevents continuous heavy use.
  • Warranty is void if used in commercial, industrial, or professional business settings.
  • Maximum safe operating temperature is 40 degrees Celsius limiting outdoor summer use.
  • Horizontal operation is mandatory during use which limits placement flexibility.
M: qwen/qwen3.5-flash-20260224

Product Specification

Power

1.1kW (230V), 1.48 HP

Intake Capacity

52.83 GPM

Output Capacity

29.06 GPM

Max Pressure

145.04 PSI

Speed

3,400 RPM

Tank Capacity

1.32 Gal

Features

Oil-free pump, Pressure reducer, Pressure regulator, 1 Cylinder, Carry handle, 2 Gauges

Noise Level

97 dB(A)

Dimensions (HxWxD)

7.48x15.75x14.96 inches

Weight

18.74 lbs

M: qwen/qwen3.5-flash-20260224

Product Description

Welcome to the Aerotec Airliner 5 GO Review

The Aerotec Airliner 5 GO Electric Compressor Manual serves as the primary guide for operating this robust machine efficiently. This oil-free portable air compressor is designed for personal and DIY tasks rather than industrial applications. It features a 1.5 HP motor and a 5-liter tank capacity ensuring steady airflow. The device operates on standard 230V electrical supply at 50Hz. Users must ensure the environment is well-ventilated with temperatures between 5 degrees and 40 degrees Celsius. Dust free air intake is crucial for motor protection.

Key Features

Safety is a top priority with this unit. It includes a maximum safety valve set at 10 Bar specifically to protect the tank integrity. If the pressure switch malfunctions, this valve releases air to prevent tank explosion. The compressor runs automatically to maintain pressure within the tank for consistent performance. However, strict adherence to the duty cycle is required for longevity. Do not operate for more than 15 percent within a single hour of running time. Overheating triggers thermal protection cutting the power automatically. It restarts once cooled down to normal levels. The oil-free design guarantees clean air output without contamination risks.

Usage Guidelines

Operation must remain horizontal during use to ensure longevity and proper internal function as specified. Tilting can damage internal components or the air pump mechanism during operation. Drain condensation daily by opening the ball valve at the tank bottom to remove moisture. Water buildup contains oil residues and must be disposed of responsibly in appropriate centers. Clean the exterior with a damp cloth only. Never use solvents which damage plastic parts. Keep away from water sources and wet hands to avoid electrical shock. Extension cables should not exceed 5 meters to prevent voltage drop.

Maintenance and Storage

Proper care extends machine life significantly. Inspect cables and plugs regularly for damage. Never remove parts without qualification or training from a service center. Store the unit vertically only when not in use to prevent internal settling or damage. Keep children and animals away from the work area at all times. Do not direct the air jet at body parts to avoid injury. Wear safety goggles always. Follow the manual instructions carefully before mounting or maintaining the compressor to ensure safety. This ensures safety and optimal performance for all pneumatic tools connected to the quick coupler. Warranty voids if used in commercial settings by the manufacturer.

Troubleshooting Common Issues

If the unit stops automatically, check for overheating and allow cooling. Low pressure might indicate leaks or clogged filters. Air leakage from the switch valve requires cleaning the seating. Ensure the plug is firmly connected to the socket. Contact authorized service centers for pressure switch failures. Do not attempt repairs yourself. Ensure the compressor is drained before packing it away. This prevents internal rust and damage during transport.

M: qwen/qwen3.5-flash-20260224