If the chimney is cold and cold plugs are created, you may experience smoke leaks during the ignition and
startup phase. In this situation there can be more smoke than usually in the combustion chamber and some
of it might leak out of the stove. Therefore, if you have a cold chimney that has not been used for a while, we
recommend that you use some wood sticks to heat the chimney and eliminate the cold plug.
5. Maintenance and cleaning of the stove
Pakninger
Med tiden bliver pakningerne slidte og bør derfor efterses. Er de utætte, bør de skiftes.
Combustion chamber
The fireproof tiles in the combustion chamber eventually wear out and should be replaced when the cracks
are more than 0.5 cm. The durability of the tiles depends on how often and how intensively the stove is used.
You can change the tiles yourself. They are available as a ready-to-use set. For further information, go to
www.aduroshop.com.
Glass
Wet wood, unsatisfactory chimney draft, and wrong use of the stove can leave soot stains on the glass pane.
They can easily be removed using a damp cloth that you dip in cold ash and rub on the sooty glass. Special
cleaning agents are also available to remove soot from glass, e.g. the Aduro Easy Clean pad. The pad
neither scratch nor damage the glass and is for multiple usage. Water or other cleaning agents are not
necessary.
It is common maintenance to tighten the glass fittings shortly after the stove has been installed as well as to
check if the gaskets are properly placed.
Gaskets
With time, gaskets around glass and door will wear. We recommend that you inspect them regularly. If
leakages appear, they must be replaced.
Ashes
Empty the ashpan before it gets completely full. Always leave a layer of ashes in the stove because it
insulates and makes it easier to light a fire.
Cleaning the stove
The stove’s surface is treated with a heat-resistant Senotherm® paint, which will stay at its best just by being
vacuumed with a small, soft mouthpiece or dusted with a soft, dry cloth. Do not use spirit or other solvents, as
they will remove the paint.
All maintenance and cleaning of the stove should be carried out when it is
cold.

Chat with your Aduro 15 manual using AI

Get instant AI answers from your Aduro 15 manual

Ask anything about the Aduro 15. Answers come from this manual, with the pages they are based on.

15 Maintenance Schedule

Remind me when maintenance is due
Yearly
Clean stove interior and flue pipe

Remove the upper refractory tile to access the top. Clean the inside of the stove and flue pipe through the door or cleaning aperture.

Show in the manual (page 40)
When needed
Inspect and replace gaskets

Check gaskets around glass and door regularly for wear or leaks. Replace if they are damaged or leaking.

Show in the manual (page 40)
When needed
Replace combustion chamber tiles

Replace fireproof tiles when cracks exceed 0.5 cm. Durability depends on usage intensity.

Show in the manual (page 40)
After installation
Tighten glass fittings

Tighten glass fittings shortly after installation and check that gaskets are properly placed.

Show in the manual (page 40)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend 15?

Yes No

Frequently Asked Questions

A

Use seasoned split hardwood and approved wood briquettes only. Maximum log length 50 cm and ideal split diameter about 10 cm. Fuel moisture should not exceed 18% to ensure efficiency and low emissions. Do not burn treated, painted, chipboard, or waste materials.

Is this answer helpful?

A

Aduro-tronic is a mechanical start-up automation that requires no electricity. You manually activate it when lighting or reloading; it times the gradual closure of the primary air to optimize combustion, improve burn efficiency, and reduce wood consumption by up to about 40%.

Is this answer helpful?

A

Recommended chimney draft is about 18–25 Pa when warm for optimal combustion; aim for ~5 Pa during cold startup. If natural draft is insufficient, consider a smoke exhauster (e.g., Aduro DraftOptimizer) and consult your chimney sweep.

Is this answer helpful?

A

Inspect gaskets and liners regularly; replace vermiculite liners when cracks exceed 0.5 cm. Clean the stove interior and flue at least annually or more often with heavy use. Empty the ashpan before it’s full and keep a thin ash layer to insulate the chamber.

Is this answer helpful?

A

The stove has a statutory two-year complaint/right-of-claim period; you can extend the warranty to five years by registering the product online within five months of purchase at the Aduro warranty site.

Is this answer helpful?

A

Check for a cold chimney or poor draft—warm the chimney with small kindling to remove a cold plug, ensure the flue and chimney are clear of obstructions, verify fresh air supply to the room, and consult a chimney sweep if problems persist.

Is this answer helpful?

A

Transport upright when possible; if laid down, secure loose internal parts. Installation must meet local regulations and be approved by the chimney sweep before use. Ensure floor load capacity or provide a load-spreading plate and fit non-combustible hearths where required.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High efficiency (78%) and Energy class A with low emissions and Nordic Ecolabel certification.
  • Aduro-tronic mechanical automation improves combustion and can reduce wood use up to 40%.
  • Flexible installation: top or rear flue (Ø150 mm), clear distance specs and compatible with masonry chimneys.
  • Robust construction with replaceable vermiculite liners, cast-iron grate, and accessible ashpan for maintenance.
  • User-friendly features: air-wash glass system, supplied Aduro key and glove, and available touch-up paint/spare parts.
VS

Disadvantages

  • Requires proper chimney draft (recommended 18–25 Pa warm) and may need a smoke exhauster if draft is insufficient.
  • Overfiring (>~3.1 kg/h) can discolor or damage lacquer and void warranty for related faults.
  • Regular maintenance needed (gaskets, liners, annual flue cleaning) to maintain efficiency and safety.
  • Installation must comply with local regulations and typically requires chimney-sweep inspection.
  • Not suitable for wet or improper fuels—no painted, treated, or waste materials; fuel moisture must be ≤18%.
M: OA-GPT-5-NAN

Product Specification

Type

Wood burning stove

Nominal heat output

22,159 BTU/h

Color

grey

Material

Steel

Fuel

Wood

Room heating capacity

up to 1,615 sq ft

Capacity

Log length 19.69 in

Efficiency

>78%

Special features

Ash pan (removable), Airwash system, Automatic fuel control

Installation type

freestanding

Dimensions

30.67x33.07x14.41in (WxHxD)

Flue pipe connection

5.91 in (diameter)

Weight

196.21 lbs

M: OA-GPT-54-NAN

Product Description

Aduro 15 — Reliable, Efficient Wood Stove

The Aduro 15 (including model 15.1) is a well-engineered convection wood stove designed for home heating with a nominal output of 6.5 kW. Certified to EN13240 and NS3058 and carrying the Nordic Ecolabel, the Aduro 15 combines solid construction, environmental performance, and user-friendly controls. Built from sheet steel with a cast-iron grate and replaceable vermiculite liners, it accepts wood and wood briquettes up to 50 cm and achieves a 78% efficiency with an energy efficiency index of 104.1 (class A).

Key features and operation

Aduro 15 offers top or rear flue connection (Ø150 mm) and includes primary, secondary and tertiary air controls for staged combustion and low emissions. The stove incorporates an air-wash system to keep the glass clear and an ashpan for easy cleaning. The patented Aduro-tronic mechanical automatic start-up device (manual activation, no electricity) times primary air closure to optimize combustion, reduce wood use by up to 40% and simplify feeding.

Installation flexibility includes clear distance and floor-plate requirements, a safety wire for secure mounting, and guidance for connecting to masonry chimneys. The stove is approved for multi-source chimneys (type 1) and is subject to local regulations and chimney-sweep inspection. Recommended chimney draft values and troubleshooting tips are provided to help ensure reliable ignition and smokeless operation.

Practical guidance and maintenance

Best results come from using dry hardwood (≤18% moisture) split to ~10 cm diameter, with ideal burn rate ~1.5 kg/hr and a maximum recommended feed of ~3.1 kg/hr. First fires should be gentle to cure paint and components. Regular maintenance includes checking and replacing door and glass gaskets, replacing cracked vermiculite liners (>0.5 cm), emptying the ashpan before full, and annual internal and flue cleaning. Surfaces are finished with heat-resistant Senotherm paint; touch-up spray is available from the manufacturer. Only original spare parts should be used; unauthorized modifications void approvals.

Notes

  • Warranty: standard 2-year complaint period extendable to 5 years by free online registration within five months of purchase.
  • Safety: never use flammable liquids, keep door closed during operation, and follow chimney-sweep sign-off before first use.
  • Accessories: Aduro offers floor plates, flue pipes, cleaning pads, firelighters and other accessories to enhance use and upkeep.