Manual.ly Logo

Aduro 15 Manual

0.0 · 0 Ratings

PDF manual · 95 Pages

English

M: OA-GPT-5-NAN
page

/ 95

Loading...
30e49b411900b1b7b60f6ccd5e3453999274 page 1e
30
Congratulations on your new Aduro Stove!
To get the best possible experience and benefit from your new Aduro wood burning stove, it is important that
you read the user manual thoroughly through before you install the stove and start using it. Errors or
incorrect settings can cause hazardous conditions and/or poor operation.
For further information, please go to www.adurofire.com.
5-year warranty – Free online registry
You have the opportunity to extend the warranty on your wood burning stove from two to five years for free.
All you need to do is register the stove at www.adurofire.com/warranty. The deadline for registering is five
months from the date of purchase.
Production number
The wood stove has a production number on the rating plate on the back of the stove. We recommend that
you note down this number in the box below before mounting the wood stove. For the purposes of the
guarantee and for other enquiries, it is important that you are able to quote this number.
Enjoy!
HOW TO SUCCEED WITH YOUR NEW WOOD STOVE
In our customer service center Aduro Customer Service you will
find tips and tricks on how to succeed with your new Aduro wood
burning stove. Here you will have direct access to interesting
content about installation and maintenance of your stove as well
as support related information. Find us here and make the most of
your Aduro wood stove.
UK

Chat with your Aduro 15 manual using AI

Get instant AI answers from your Aduro 15 manual

Ask anything about the Aduro 15. Answers come from this manual, with the pages they are based on.

15 Maintenance Schedule

Remind me when maintenance is due
Yearly
Clean stove interior and flue pipe

Remove the upper refractory tile to access the top. Clean the inside of the stove and flue pipe through the door or cleaning aperture.

Show in the manual (page 40)
When needed
Inspect and replace gaskets

Check gaskets around glass and door regularly for wear or leaks. Replace if they are damaged or leaking.

Show in the manual (page 40)
When needed
Replace combustion chamber tiles

Replace fireproof tiles when cracks exceed 0.5 cm. Durability depends on usage intensity.

Show in the manual (page 40)
After installation
Tighten glass fittings

Tighten glass fittings shortly after installation and check that gaskets are properly placed.

Show in the manual (page 40)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend 15?

Yes No

Frequently Asked Questions

A

Use seasoned split hardwood and approved wood briquettes only. Maximum log length 50 cm and ideal split diameter about 10 cm. Fuel moisture should not exceed 18% to ensure efficiency and low emissions. Do not burn treated, painted, chipboard, or waste materials.

Is this answer helpful?

A

Aduro-tronic is a mechanical start-up automation that requires no electricity. You manually activate it when lighting or reloading; it times the gradual closure of the primary air to optimize combustion, improve burn efficiency, and reduce wood consumption by up to about 40%.

Is this answer helpful?

A

Recommended chimney draft is about 18–25 Pa when warm for optimal combustion; aim for ~5 Pa during cold startup. If natural draft is insufficient, consider a smoke exhauster (e.g., Aduro DraftOptimizer) and consult your chimney sweep.

Is this answer helpful?

A

Inspect gaskets and liners regularly; replace vermiculite liners when cracks exceed 0.5 cm. Clean the stove interior and flue at least annually or more often with heavy use. Empty the ashpan before it’s full and keep a thin ash layer to insulate the chamber.

Is this answer helpful?

A

The stove has a statutory two-year complaint/right-of-claim period; you can extend the warranty to five years by registering the product online within five months of purchase at the Aduro warranty site.

Is this answer helpful?

A

Check for a cold chimney or poor draft—warm the chimney with small kindling to remove a cold plug, ensure the flue and chimney are clear of obstructions, verify fresh air supply to the room, and consult a chimney sweep if problems persist.

Is this answer helpful?

A

Transport upright when possible; if laid down, secure loose internal parts. Installation must meet local regulations and be approved by the chimney sweep before use. Ensure floor load capacity or provide a load-spreading plate and fit non-combustible hearths where required.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High efficiency (78%) and Energy class A with low emissions and Nordic Ecolabel certification.
  • Aduro-tronic mechanical automation improves combustion and can reduce wood use up to 40%.
  • Flexible installation: top or rear flue (Ø150 mm), clear distance specs and compatible with masonry chimneys.
  • Robust construction with replaceable vermiculite liners, cast-iron grate, and accessible ashpan for maintenance.
  • User-friendly features: air-wash glass system, supplied Aduro key and glove, and available touch-up paint/spare parts.
VS

Disadvantages

  • Requires proper chimney draft (recommended 18–25 Pa warm) and may need a smoke exhauster if draft is insufficient.
  • Overfiring (>~3.1 kg/h) can discolor or damage lacquer and void warranty for related faults.
  • Regular maintenance needed (gaskets, liners, annual flue cleaning) to maintain efficiency and safety.
  • Installation must comply with local regulations and typically requires chimney-sweep inspection.
  • Not suitable for wet or improper fuels—no painted, treated, or waste materials; fuel moisture must be ≤18%.
M: OA-GPT-5-NAN

Product Specification

Type

Wood burning stove

Nominal heat output

22,159 BTU/h

Color

grey

Material

Steel

Fuel

Wood

Room heating capacity

up to 1,615 sq ft

Capacity

Log length 19.69 in

Efficiency

>78%

Special features

Ash pan (removable), Airwash system, Automatic fuel control

Installation type

freestanding

Dimensions

30.67x33.07x14.41in (WxHxD)

Flue pipe connection

5.91 in (diameter)

Weight

196.21 lbs

M: OA-GPT-54-NAN

Product Description

Aduro 15 — Reliable, Efficient Wood Stove

The Aduro 15 (including model 15.1) is a well-engineered convection wood stove designed for home heating with a nominal output of 6.5 kW. Certified to EN13240 and NS3058 and carrying the Nordic Ecolabel, the Aduro 15 combines solid construction, environmental performance, and user-friendly controls. Built from sheet steel with a cast-iron grate and replaceable vermiculite liners, it accepts wood and wood briquettes up to 50 cm and achieves a 78% efficiency with an energy efficiency index of 104.1 (class A).

Key features and operation

Aduro 15 offers top or rear flue connection (Ø150 mm) and includes primary, secondary and tertiary air controls for staged combustion and low emissions. The stove incorporates an air-wash system to keep the glass clear and an ashpan for easy cleaning. The patented Aduro-tronic mechanical automatic start-up device (manual activation, no electricity) times primary air closure to optimize combustion, reduce wood use by up to 40% and simplify feeding.

Installation flexibility includes clear distance and floor-plate requirements, a safety wire for secure mounting, and guidance for connecting to masonry chimneys. The stove is approved for multi-source chimneys (type 1) and is subject to local regulations and chimney-sweep inspection. Recommended chimney draft values and troubleshooting tips are provided to help ensure reliable ignition and smokeless operation.

Practical guidance and maintenance

Best results come from using dry hardwood (≤18% moisture) split to ~10 cm diameter, with ideal burn rate ~1.5 kg/hr and a maximum recommended feed of ~3.1 kg/hr. First fires should be gentle to cure paint and components. Regular maintenance includes checking and replacing door and glass gaskets, replacing cracked vermiculite liners (>0.5 cm), emptying the ashpan before full, and annual internal and flue cleaning. Surfaces are finished with heat-resistant Senotherm paint; touch-up spray is available from the manufacturer. Only original spare parts should be used; unauthorized modifications void approvals.

Notes

  • Warranty: standard 2-year complaint period extendable to 5 years by free online registration within five months of purchase.
  • Safety: never use flammable liquids, keep door closed during operation, and follow chimney-sweep sign-off before first use.
  • Accessories: Aduro offers floor plates, flue pipes, cleaning pads, firelighters and other accessories to enhance use and upkeep.
M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly