52-230-1005 Maintenance Schedule
Check the charging cable and contacts for damage and dirt before every use.
Only clean when disconnected using a dry cloth; never use water or harsh agents.
Ask a Question
Do you recommend 52-230-1005?
Yes NoFrequently Asked Questions
The cable is compatible with electric and hybrid vehicles that accept IEC 62196-2 Type 2 inlets. It supports three-phase AC charging and works with vehicles that regulate charging current up to 16A.
Is this answer helpful?
The cable includes an RCD (30mA AC + 6mA DC) and protection against overvoltage, undervoltage, overcurrent, residual current faults, PE line faults and overheating. LED diagnostics and automatic interruptions help prevent unsafe conditions.
Is this answer helpful?
No. The manual explicitly forbids using extension cables, multiple sockets or adapters. Doing so is unsafe and voids the warranty. Always connect directly to a suitable 16A CEE socket.
Is this answer helpful?
Connect the mains plug to a 400V 16A CEE socket, ensure the green LED indicates readiness, remove the protective cap and plug the Type 2 connector into the vehicle. Charging starts when the blue LED flashes and completes when blue and green LEDs remain steady. Disconnect vehicle plug first, then mains plug.
Is this answer helpful?
Clean only when disconnected using a dry cloth; do not use water, steam or aggressive cleaners. Store the cable with protective caps in a dry, clean place. Inspect for damage before each use and do not use if any part is compromised.
Is this answer helpful?
The control box will interrupt charging on overheating or detected faults (e.g., leakage current, PE error). Check connectors for contamination, allow the unit to cool, verify mains supply and consult a qualified technician if needed; return to manufacturer if fault persists.
Is this answer helpful?
The product comes with a 2-year warranty covering manufacturing defects. It conforms to IEC 62196-2 and IEC 61851-1 standards and meets applicable EU directives; misuse, unauthorized modifications or damage from improper use are not covered.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Supports three-phase charging up to 11 kW with selectable currents (8A/10A/13A/16A).
- Comprehensive safety features: RCD (30mA AC + 6mA DC), over/under-voltage, overcurrent and PE monitoring.
- Clear LCD and LED indicators display live charging metrics and fault states for easy diagnostics.
- Durable construction with IP55/IP54 protection, high insulation, and ≥10,000 plug cycles rated.
- 6m total cable length (5+1m) offers flexible reach for typical home and protected outdoor setups.
Disadvantages
- Requires a 16A CEE socket; not compatible with standard domestic outlets without proper infrastructure.
- Charging current cannot be changed during an active charging session.
- Not for use with extension cords, adapters or in unprotected wet conditions, limiting some use cases.
- Overheating (e.g., direct sunlight) can interrupt charging until the control box cools down.
- Warranty (2 years) voided by misuse or unauthorized modifications.
Product Specification
Number of charging points
1
Max. charging power
11 kW 3-phase
Number of phases
3-phase
Voltage
400V (AC)
Max. current per phase
16A
Current limitation
adjustable 8-16A
Connection type
Type 2
Connection method
Cable 19.69 ft
Installation type
mobile charging station
Special features
Display, mobile charging station
Protection class
IP54
Dimensions
7.48x2.64x1.77in (WxHxD)
Weight
6.17 lb
Product Description
Absina Charging Cable CEE to Type 2/CCS 11kW, 6m Charging Cable Manual
The Absina Charging Cable CEE to Type 2/CCS 11kW, 6m Charging Cable is a robust Mode 2 AC charging solution designed for safe, reliable home and protected outdoor charging of electric and hybrid vehicles. Built to IEC 62196-2 Type 2 standards, this three-phase cable supports up to 11 kW (8A–16A selectable) and connects to 16A CEE sockets. It includes a control box with LCD and LED indicators for supply voltage, current, charge energy and status, plus sensor buttons to set charging current and delayed start time (1–10 hours). The cable length (5+1 m) and durable construction with IP55/IP54 protection ratings make it suitable for regular use while offering safeguards against over/under-voltage, overcurrent, residual current, PE faults and overheating.
Key Features and Use
Absina’s cable is intended exclusively for charging electric and hybrid vehicles with compatible Type 2 inlets. The unit features a control box with an LCD showing live metrics (current, kW, kWh, temperature) and LED status indicators (green/blue/red) that signal standby, charging, charge complete and multiple fault conditions (self-test failure, undervoltage/overvoltage, leakage current, overcurrent, PE error, overheating). A built-in RCD (30mA AC + 6mA DC) enhances safety. The cable’s technical profile includes contact resistance ≤0.3 mΩ, insulation 500 MΩ, dielectric strength 2,600 V AC, and a certified pull-off force and plug cycle durability.
Operation and Maintenance
To start charging: connect the mains plug to a 400V 16A CEE socket, check the green LED for readiness, remove the protective cap and connect the Type 2 plug to the vehicle. Charging begins when the blue LED flashes and completes when blue and green LEDs are steady. After charging disconnect vehicle plug first, then mains. Use sensor controls to choose charging current (8A/10A/13A/16A) and to set delayed start. Clean only when disconnected, using a dry cloth; never immerse in liquids or use harsh cleaners. Store with protective caps in a dry area.
Safety and Compliance
Follow safety instructions strictly: only connect to suitable, fault-free CEE 16A infrastructure, avoid extension leads, adapters or damaged components, and protect the cable from direct sunlight and moisture. If connections smoke or melt, stop charging and isolate power. The product meets EU directives and relevant IEC standards and includes environmental disposal guidance. A 2-year warranty covers manufacturing faults but not misuse.
Notes
- Designed for protected outdoor use; avoid direct sunlight during charging to prevent overheating interruptions.
- Charging current is regulated by the vehicle; actual power may vary.
- Keep out of reach of children and operated only by licensed drivers.