Loading...
368007911f86c10874f0aee866a5d1900416 page 7
Follow the operating instructions!
Do not expose to direct sunlight!
INTENDED USE
Use the cable exclusively for charging electric and
hybrid vehicles with alternating current (AC) at CEE
sockets with 16A load capacity. The cable may only be
used in conjunction with standardised and designated
vehicle inlets according to IEC 62196-2 (type 2 plug).
Compliance with all the information in these operating
instructions is also part of the intended use. Any other
use or use beyond this is considered misuse and can
lead to dangerous situations. The user is liable for any
damage caused by improper use.
SAFETY INSTRUCTIONS
• Only connect to a fault-free and suitable
infrastructure (16A CEE socket). If in doubt, have a
specialist check the suitability. Make sure that the
fuse is not overloaded and that no other loads are
connected to this fuse.
• Improper handling of the charging cable can cause
explosions, electric shocks and short circuits.
Observe the generally applicable safety precautions
and the instructions.
• Before each use, check the charging cable and the
contacts for damage and dirt.
• Never charge with a damaged charging cable, vehicle
inlet, control box or CEE socket.
• Never charge with contacts that have become dirty
or damp.
• Never pull off the plug by force. Dangerous electric
arcs can cause death or serious injury.
Deutsch . English . Français . Español . Italiano
WELCOME
Thank you for purchasing your new ABSINA EV charging
cable mode 2. With the help of the operating
instructions, you will be able to use the functions of
your charging cable optimally. We hope you enjoy using
your new charging cable.
Your ABSINA team.
EXPLANATION OF SYMBOLS
The product complies with the requirements
of the EU Directive.
Do not dispose of the product in household
waste! Dispose of the product at an
authorised waste disposal company or at a
municipal waste disposal facility. Observe
the currently valid regulations. In case of
doubt, contact the disposal facility.
Attention! A dangerous situation may occur
if the measures are not observed.
Risk of death, serious injury and burns!
Do not use charging cables that are damaged at
the housing, plug or cable!
Do not use extension cables of any kind!
Do not use multiple sockets!
Do not use travel adapters!
Vehicle coupling type 2

Chat with your Absina 52-230-1005 manual using AI

Get instant AI answers from your Absina 52-230-1005 manual

Ask anything about the Absina 52-230-1005. Answers come from this manual, with the pages they are based on.

52-230-1005 Maintenance Schedule

Before each use
Inspect cable and contacts

Check the charging cable and contacts for damage and dirt before every use.

As needed
Clean cable and contacts

Only clean when disconnected using a dry cloth; never use water or harsh agents.

M: QW-35-FL

Ask a Question

0/1000

Do you recommend 52-230-1005?

Yes No

Frequently Asked Questions

A

The cable is compatible with electric and hybrid vehicles that accept IEC 62196-2 Type 2 inlets. It supports three-phase AC charging and works with vehicles that regulate charging current up to 16A.

Is this answer helpful?

A

The cable includes an RCD (30mA AC + 6mA DC) and protection against overvoltage, undervoltage, overcurrent, residual current faults, PE line faults and overheating. LED diagnostics and automatic interruptions help prevent unsafe conditions.

Is this answer helpful?

A

No. The manual explicitly forbids using extension cables, multiple sockets or adapters. Doing so is unsafe and voids the warranty. Always connect directly to a suitable 16A CEE socket.

Is this answer helpful?

A

Connect the mains plug to a 400V 16A CEE socket, ensure the green LED indicates readiness, remove the protective cap and plug the Type 2 connector into the vehicle. Charging starts when the blue LED flashes and completes when blue and green LEDs remain steady. Disconnect vehicle plug first, then mains plug.

Is this answer helpful?

A

Clean only when disconnected using a dry cloth; do not use water, steam or aggressive cleaners. Store the cable with protective caps in a dry, clean place. Inspect for damage before each use and do not use if any part is compromised.

Is this answer helpful?

A

The control box will interrupt charging on overheating or detected faults (e.g., leakage current, PE error). Check connectors for contamination, allow the unit to cool, verify mains supply and consult a qualified technician if needed; return to manufacturer if fault persists.

Is this answer helpful?

A

The product comes with a 2-year warranty covering manufacturing defects. It conforms to IEC 62196-2 and IEC 61851-1 standards and meets applicable EU directives; misuse, unauthorized modifications or damage from improper use are not covered.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Supports three-phase charging up to 11 kW with selectable currents (8A/10A/13A/16A).
  • Comprehensive safety features: RCD (30mA AC + 6mA DC), over/under-voltage, overcurrent and PE monitoring.
  • Clear LCD and LED indicators display live charging metrics and fault states for easy diagnostics.
  • Durable construction with IP55/IP54 protection, high insulation, and ≥10,000 plug cycles rated.
  • 6m total cable length (5+1m) offers flexible reach for typical home and protected outdoor setups.
VS

Disadvantages

  • Requires a 16A CEE socket; not compatible with standard domestic outlets without proper infrastructure.
  • Charging current cannot be changed during an active charging session.
  • Not for use with extension cords, adapters or in unprotected wet conditions, limiting some use cases.
  • Overheating (e.g., direct sunlight) can interrupt charging until the control box cools down.
  • Warranty (2 years) voided by misuse or unauthorized modifications.
M: OA-GPT-5-NAN

Product Specification

Number of charging points

1

Max. charging power

11 kW 3-phase

Number of phases

3-phase

Voltage

400V (AC)

Max. current per phase

16A

Current limitation

adjustable 8-16A

Connection type

Type 2

Connection method

Cable 19.69 ft

Installation type

mobile charging station

Special features

Display, mobile charging station

Protection class

IP54

Dimensions

7.48x2.64x1.77in (WxHxD)

Weight

6.17 lb

M: OA-GPT-54-NAN

Product Description

Absina Charging Cable CEE to Type 2/CCS 11kW, 6m Charging Cable Manual

The Absina Charging Cable CEE to Type 2/CCS 11kW, 6m Charging Cable is a robust Mode 2 AC charging solution designed for safe, reliable home and protected outdoor charging of electric and hybrid vehicles. Built to IEC 62196-2 Type 2 standards, this three-phase cable supports up to 11 kW (8A–16A selectable) and connects to 16A CEE sockets. It includes a control box with LCD and LED indicators for supply voltage, current, charge energy and status, plus sensor buttons to set charging current and delayed start time (1–10 hours). The cable length (5+1 m) and durable construction with IP55/IP54 protection ratings make it suitable for regular use while offering safeguards against over/under-voltage, overcurrent, residual current, PE faults and overheating.

Key Features and Use

Absina’s cable is intended exclusively for charging electric and hybrid vehicles with compatible Type 2 inlets. The unit features a control box with an LCD showing live metrics (current, kW, kWh, temperature) and LED status indicators (green/blue/red) that signal standby, charging, charge complete and multiple fault conditions (self-test failure, undervoltage/overvoltage, leakage current, overcurrent, PE error, overheating). A built-in RCD (30mA AC + 6mA DC) enhances safety. The cable’s technical profile includes contact resistance ≤0.3 mΩ, insulation 500 MΩ, dielectric strength 2,600 V AC, and a certified pull-off force and plug cycle durability.

Operation and Maintenance

To start charging: connect the mains plug to a 400V 16A CEE socket, check the green LED for readiness, remove the protective cap and connect the Type 2 plug to the vehicle. Charging begins when the blue LED flashes and completes when blue and green LEDs are steady. After charging disconnect vehicle plug first, then mains. Use sensor controls to choose charging current (8A/10A/13A/16A) and to set delayed start. Clean only when disconnected, using a dry cloth; never immerse in liquids or use harsh cleaners. Store with protective caps in a dry area.

Safety and Compliance

Follow safety instructions strictly: only connect to suitable, fault-free CEE 16A infrastructure, avoid extension leads, adapters or damaged components, and protect the cable from direct sunlight and moisture. If connections smoke or melt, stop charging and isolate power. The product meets EU directives and relevant IEC standards and includes environmental disposal guidance. A 2-year warranty covers manufacturing faults but not misuse.

Notes

  • Designed for protected outdoor use; avoid direct sunlight during charging to prevent overheating interruptions.
  • Charging current is regulated by the vehicle; actual power may vary.
  • Keep out of reach of children and operated only by licensed drivers.