ZI-MUP750 Maintenance Schedule
After each workshift, clean the machine thoroughly. Clean suction slots with clear water if necessary. Use only mild detergent; avoid solvents or abrasive agents.
Verify that all safety equipment is in perfect working order before every start of operation to prevent accidents and malfunctions.
Check regularly that warning and safety stickers on the machine are present and legible. Replace them immediately if missing or unreadable.
Ask a Question
Do you recommend ZI-MUP750?
Yes NoFrequently Asked Questions
No, this pump is strictly prohibited for conveying drinking water, foodstuffs, or liquids containing high concentrations of salt or chemicals. It is designed for clear water, rainwater, and chlorinated pool water only.
Is this answer helpful?
The pump uses a built-in float switch that detects water levels. When the water rises to a set point, the pump turns on. When the water level drops below the switch-off height, the pump automatically turns off to prevent dry running.
Is this answer helpful?
The Zipper ZI-MUP750 can be safely submerged to a maximum depth of 7 meters. Ensure the pump is suspended securely or standing firmly on the bottom during operation.
Is this answer helpful?
No, the machine must not be used in continuous operation mode. It is designed for intermittent use to prevent overheating and mechanical failure.
Is this answer helpful?
After each use, clean the suction slots with clear water. Avoid using solvents, aggressive chemicals, or abrasive scrubbing agents as these can damage the pump housing.
Is this answer helpful?
Check if the impeller is blocked by dirt, verify the thermal switch has reset, ensure there is mains power, and confirm the float switch is functioning correctly. Disconnect power before inspecting.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- High flow rate of 12,000 liters per hour for rapid drainage
- Automatic operation with adjustable float switch prevents dry running
- IPX8 protection rating ensures safe full submersion
- Durable design handles rain, clear, and chlorinated water effectively
- Long 10-meter power cable provides flexible placement options
Disadvantages
- Not suitable for drinking water, saltwater, or aggressive chemicals
- Cannot be used continuously without rest periods
- Float switch requires manual adjustment for specific water levels
- Heavier weight compared to lower wattage models
- Requires regular cleaning of suction slots to maintain efficiency
Product Specification
Power
750W
Flow rate
3170 gal/h
Max head
32.81ft
Submersion depth
22.97ft
Features
without tank
Cable length
32.81ft
Weight
14.99lbs
Product Description
The Zipper ZI-MUP750 Combination Electric Submersible Pump
The Zipper ZI-MUP750 Combination Electric Submersible Pump is a robust and versatile solution designed for efficient water management in residential, garden, and agricultural settings. This powerful unit features a 750-watt motor capable of delivering up to 12,000 liters per hour, making it ideal for draining containers, emptying wells, or managing floodwater quickly. Unlike smaller models, the ZI-MUP750 boasts a maximum head of delivery of 10 meters and can handle immersion depths up to 7 meters with ease.
Designed with safety and durability in mind, this pump includes an integrated float switch that automatically activates when water levels rise and shuts off when they drop, ensuring unattended operation without risk of dry running. The device meets strict IPX8 protection standards, allowing it to be fully submerged while maintaining electrical safety. Users appreciate the durable construction which handles clear water, rainwater, and chlorinated pool water effectively, though it is not suitable for aggressive chemicals or saltwater.
Assembly is straightforward, requiring only the attachment of a hose adapter and securing the connection cable. The unit comes with a 10-meter power cord and a specific float switch cable length recommended at approximately 120 mm for optimal performance. Regular maintenance involves simple cleaning of suction slots with water and storing the unit dry to prevent seal adhesion. Always ensure the power plug is disconnected before any maintenance or handling to avoid electric shock hazards.
Key Features
- High capacity pumping speed of 12,000 l/h
- Automatic on/off via adjustable float switch
- Robust IPX8 waterproof rating
- Suitable for various water types including rain and pool water
Important Notes
- Do not use for drinking water or food products.
- Never operate without water as it may damage the seals.
- Always use a residual current device (RCD) for safety.