MAINTENANCE
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at 17
ZI-MUP350 / ZI-MUP750
14 MAINTENANCE
AT TE N TI ON
Perform all maintenance machine settings with the machine being
disconnected from the power supply!
Serious injury due to unintentional or automatic activation of the machine!
The machine does not require extensive maintenance. If malfunctions and defects occur, let it be
serviced by trained persons only.
NO TI C E
Clean your machine regularly after every usage – it prolongs the machines lifespan and is a pre-
requisite for a safe working environment.
Repair jobs shall be performed by respectively trained professionals only!
Check regularly the condition of the security stickers. Replace them if required.
Check regularly the condition of the machine.
14.1 Cleaning
After each workshift the machine has to be cleaned.
Clean the suction slots on the suction foot if necessary with clear water.
NO TI C E
The usage of certain solutions containing ingredients damaging metal surfaces
as well as the use of scrubbing agents will damage the machine surface!
Clean the machine surface with a wet cloth soaked in a mild detergent
14.2 Storing
Make sure there is no water in the machine. The machine has to be completely emptied and stored
in a try area with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse
the pump with appropriate oil (for example, with vegetable oil).
14.3 Disposal
Do not dispose the machine in residual waste. Contact your local authorities for
information regarding the available disposal options. When you buy at your local dealer for
a replacement unit, the latter is obliged to exchange your old.

Chat with your Zipper ZI-MUP750 manual using AI

Get instant AI answers from your Zipper ZI-MUP750 manual

Ask anything about the Zipper ZI-MUP750. Answers come from this manual, with the pages they are based on.

ZI-MUP750 Maintenance Schedule

After each use
Clean the machine and suction slots

After each workshift, clean the machine thoroughly. Clean suction slots with clear water if necessary. Use only mild detergent; avoid solvents or abrasive agents.

Show in the manual (page 17)
Before each operation
Check safety devices condition

Verify that all safety equipment is in perfect working order before every start of operation to prevent accidents and malfunctions.

Show in the manual (page 10)
Regularly
Inspect warning labels

Check regularly that warning and safety stickers on the machine are present and legible. Replace them immediately if missing or unreadable.

Show in the manual (page 10)
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend ZI-MUP750?

Yes No

Frequently Asked Questions

A

No, this pump is strictly prohibited for conveying drinking water, foodstuffs, or liquids containing high concentrations of salt or chemicals. It is designed for clear water, rainwater, and chlorinated pool water only.

Is this answer helpful?

A

The pump uses a built-in float switch that detects water levels. When the water rises to a set point, the pump turns on. When the water level drops below the switch-off height, the pump automatically turns off to prevent dry running.

Is this answer helpful?

A

The Zipper ZI-MUP750 can be safely submerged to a maximum depth of 7 meters. Ensure the pump is suspended securely or standing firmly on the bottom during operation.

Is this answer helpful?

A

No, the machine must not be used in continuous operation mode. It is designed for intermittent use to prevent overheating and mechanical failure.

Is this answer helpful?

A

After each use, clean the suction slots with clear water. Avoid using solvents, aggressive chemicals, or abrasive scrubbing agents as these can damage the pump housing.

Is this answer helpful?

A

Check if the impeller is blocked by dirt, verify the thermal switch has reset, ensure there is mains power, and confirm the float switch is functioning correctly. Disconnect power before inspecting.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High flow rate of 12,000 liters per hour for rapid drainage
  • Automatic operation with adjustable float switch prevents dry running
  • IPX8 protection rating ensures safe full submersion
  • Durable design handles rain, clear, and chlorinated water effectively
  • Long 10-meter power cable provides flexible placement options
VS

Disadvantages

  • Not suitable for drinking water, saltwater, or aggressive chemicals
  • Cannot be used continuously without rest periods
  • Float switch requires manual adjustment for specific water levels
  • Heavier weight compared to lower wattage models
  • Requires regular cleaning of suction slots to maintain efficiency
M: QW-35-FL

Product Specification

Power

750W

Flow rate

3170 gal/h

Max head

32.81ft

Submersion depth

22.97ft

Features

without tank

Cable length

32.81ft

Weight

14.99lbs

M: QW-35-FL

Product Description

The Zipper ZI-MUP750 Combination Electric Submersible Pump

The Zipper ZI-MUP750 Combination Electric Submersible Pump is a robust and versatile solution designed for efficient water management in residential, garden, and agricultural settings. This powerful unit features a 750-watt motor capable of delivering up to 12,000 liters per hour, making it ideal for draining containers, emptying wells, or managing floodwater quickly. Unlike smaller models, the ZI-MUP750 boasts a maximum head of delivery of 10 meters and can handle immersion depths up to 7 meters with ease.

Designed with safety and durability in mind, this pump includes an integrated float switch that automatically activates when water levels rise and shuts off when they drop, ensuring unattended operation without risk of dry running. The device meets strict IPX8 protection standards, allowing it to be fully submerged while maintaining electrical safety. Users appreciate the durable construction which handles clear water, rainwater, and chlorinated pool water effectively, though it is not suitable for aggressive chemicals or saltwater.

Assembly is straightforward, requiring only the attachment of a hose adapter and securing the connection cable. The unit comes with a 10-meter power cord and a specific float switch cable length recommended at approximately 120 mm for optimal performance. Regular maintenance involves simple cleaning of suction slots with water and storing the unit dry to prevent seal adhesion. Always ensure the power plug is disconnected before any maintenance or handling to avoid electric shock hazards.

Key Features

  • High capacity pumping speed of 12,000 l/h
  • Automatic on/off via adjustable float switch
  • Robust IPX8 waterproof rating
  • Suitable for various water types including rain and pool water

Important Notes

  • Do not use for drinking water or food products.
  • Never operate without water as it may damage the seals.
  • Always use a residual current device (RCD) for safety.