d9dc275feb7af3e788acddeef66ec829c757 page 14
2608C.p65 20 ?2009/6/5, 下午 04:18
20
9427370000_00/06.2019
INTRODUCTION
This manual contains information and warnings which must be followed
to ensure safe operation and retain the meter in safe condition.
READ "SAFETY INFORMATION" BEFORE USING THE METER.
This clamp meter is a handheld 6600-count instrument that is designed
for use in the laboratory, field servicing, at home, and any circumstance
where high current measurement is required.The clamp meter is built with
a design of finger guard which ensures users operating the instrument
under a safety situation; a rugged case that is shock resistant and fire-
retardant; and electronic overload protection for all functions and ranges.
In addition, a carrying case (optional accessory) is available for easy
portability of the meter and avoiding damage.
Scope of delivery
˗ Digital Clamp Meter (DCM)
˗ Test lead set (one black, one red)
˗ 9-V battery (installed in the meter)
˗
Operating instructions
If any of the above items are missing or are received in a damaged condition,
please contact the distributor from whom you purchased the unit.
SAFETY INFORMATION
The following safety precautions must be observed to ensure maximum
personal safety during the operation, service and repair of this meter:

Chat with your Weidmuller C 2606 manual using AI

Get instant AI answers from your Weidmuller C 2606 manual

Ask anything about the Weidmuller C 2606. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend C 2606?

Yes No

Frequently Asked Questions

A

It measures AC current up to 1500 A and DC current up to 2000 A using its clamp jaws. The 2000 A DC range is specified for a maximum of 60 seconds. Always clamp around one conductor only and keep it centered in the jaws for the best reading.

Is this answer helpful?

A

Yes. The meter provides True RMS measurement for AC voltage and AC current. This is useful when testing electrical signals that may not be clean sine waves, such as outputs from variable-speed drives or other electronic equipment.

Is this answer helpful?

A

The meter measures AC and DC voltage, resistance, continuity, diodes, capacitance, frequency, and duty cycle. It also includes manual and automatic ranging, relative measurements, data hold, peak capture, MAX/MIN recording, and a backlight.

Is this answer helpful?

A

The meter is rated CAT III 1000 V and CAT IV 600 V and conforms to IEC 61010-1 and IEC 61010-2-032. It has double insulation, a finger guard, a rugged flame-retardant case, and overload protection. Follow safe work procedures and stated limits.

Is this answer helpful?

A

The clamp jaw opening accommodates a conductor up to 57 mm in diameter or a bus bar up to 70 x 18 mm. This capacity makes the meter appropriate for larger conductors encountered in distribution and industrial electrical work.

Is this answer helpful?

A

The meter uses one standard 9 V battery, specified as NEDA 1604, IEC 6F22, JIS 006P, or an equivalent type. Typical battery life is approximately 75 hours with a carbon-zinc battery. Replace the battery when the low-battery indicator appears.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • True RMS AC measurement supports more reliable readings on non-sinusoidal electrical signals.
  • Clamp measures up to 1500 A AC and 2000 A DC without opening the conductor.
  • Includes voltage, resistance, continuity, diode, capacitance, frequency, and duty-cycle functions.
  • CAT III 1000 V and CAT IV 600 V ratings support demanding installation work.
  • Features hold, relative zero, MAX/MIN, peak capture, backlight, and auto-ranging.
VS

Disadvantages

  • DC current measurements above 1000 A have reduced stated accuracy and are limited to 60 seconds at 2000 A.
  • The backlight operates for approximately 60 seconds, which may be short for extended low-light work.
  • The optional carrying case is not listed as a standard included accessory.
  • Capacitance testing requires the capacitor to be discharged and may need relative zeroing.
  • The meter is relatively large and weighs about 570 g including the battery.
M: gpt-5.6-terra

Product Specification

Measuring range

max. 2,000 A, max. 750 V, max. 66 MOhm

M: gpt-5.6-terra

Product Description

Weidmuller C 2606 Multimeter - Read, Download & Print Free

The Weidmuller C 2606 Multimeter is a capable digital clamp meter created for electricians, maintenance teams, field technicians, and users who need to evaluate electrical systems safely and efficiently. Its clamp-style design allows current measurement around a single conductor without interrupting the circuit, making it especially useful for high-current applications in panels, equipment, and building installations.

Built for versatile electrical testing

This True RMS meter combines AC and DC current measurement with core multimeter functions. It measures DC voltage up to 1000 V and AC voltage up to 750 V, while the clamp supports AC current up to 1500 A and DC current up to 2000 A for limited-duration measurements. A 6600-count display and 66-segment analog bar graph provide clear readings and responsive visual feedback.

Beyond voltage and current, the instrument supports resistance, continuity, diode, capacitance, frequency, and duty-cycle testing. This broad function set makes the Weidmuller C 2606 Multimeter suitable for troubleshooting motors, power supplies, control circuits, capacitors, and general electrical installations. Continuity testing includes an audible indication below approximately 30 ohms, helping users identify connections quickly.

Practical controls for field work

A rotary selector provides direct access to measurement modes and ranges. Automatic ranging simplifies routine work, while manual range selection gives experienced users more control over resolution. Additional functions include relative zero, data hold, MAX/MIN recording, peak capture for AC measurements, and a temporary backlight for low-light environments.

The large clamp jaw accepts conductors up to 57 mm and bus bars up to 70 x 18 mm. A rugged, shock-resistant, flame-retardant housing and finger guard support dependable use in demanding work areas. Automatic power-off after about 30 minutes helps preserve the installed 9 V battery, and the feature can be disabled when longer monitoring is needed.

Safety-focused performance

The meter is rated CAT III 1000 V and CAT IV 600 V, with double insulation and electronic overload protection across its functions. These ratings support use on building installations and at low-voltage installation sources when correct procedures, measurement limits, and personal protective equipment are followed.

Notes

  • Inspect the meter, leads, and insulation before every use.
  • Remove test leads before measuring current with the clamp.
  • Discharge capacitors before capacitance testing.
  • Calibration and repairs should be performed by qualified technicians only.

The Weidmuller C 2606 Multimeter offers a strong balance of high-current capability, wide measurement coverage, practical display features, and professional safety design for everyday electrical diagnostics.