Manual.ly Logo

V-Tac 38W UV-C Germicidal Lamp with Ozone Manual

0.0 · 0 Ratings

PDF manual · 14 Pages

English

M: QW-35-FL
page

/ 14

Loading...
c9d89359e7596897df473d9cee321921de2f page 1
WEEE Number
: 80133970
INSTALLATION INSTRUCTION
IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT: SUPPORT@V-TAC.EU
FOR MORE PRODUCTS RANGE, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST DEALERS.
V-TAC EUROPE LTD. BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B
OPERATING & SAFETY INSTRUCTION:
1. Read the instructions carefully before using the lamp.
2. Check the local voltage before using the product. Plug in the appliance under normal input
voltage (please ensure the power is off before plugging in the appliance). To Switch ON the
lamp press the touch switch and wait for 10 seconds for the lamp to power ON (the appliance
will notify with sounds before starting). Built with 30 minutes timer function, when the lamp is
powered on it works only for 30 minutes and turns off automatically by timer. The appliance
can be powered off before the timer limit of 30 minutes by pressing the touch switch or by
pulling out the plug to cut the power supply.
3. Humans and animals should not be near the lamp once it has been powered ON.
4. Avoid looking directly into the light. Avoid eye and skin exposure to unshielded product.
Use only in an enclosed environment which shields
users from the radiation. During sterilization, human and animal must get out from the place.
Absorbing too much ultraviolet light can cause skin irritation and conjunctival damage
5. The lamp is with ozone which is an unstable toxic gas with a pungent odor and powerful
oxidizing properties. Exposure in high levels to ozone may cause harm to humans.
6. After sterilization it is advised to ventilate the place for 20-30 minutes. The lamp emits
ozone, intense exposure of which is harmful.
7. Repairs should be carried out by the manufacturer or qualified electricians ONLY. Never
remove any fixed part of the appliance to make any internal adjustment. If the supply cord of
the lamp or other part of appliance is damaged, the manufacturer or its service agent or
similarly qualified person must replace it in order to avoid a hazard.
8. Unplug the lamp before cleaning. Make sure the to clean the lamp(tube). Any dusty or
stains on the glass would affect the sterilization.
Do not use alcohol, gasoline or chemicals to clean the appliance. Be sure to cut off the
electricity when cleaning and repairing the appliance.
9. Make sure that your local voltage and frequency should be suitable for the lamp.
10.This appliance is not intended for use by persons (including children) with reduced physi-
cal, sensory or mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the appliance by a person responsible
for their safety.
11. Children should be supervised to ensure that they do not play with the appliance.
12. The appliance is for indoor use only. The appliance is not to be used in locations where
flammable vapors or explosive dust is likely to exist. Hang or mount the appliance on a place
where children can’t reach.
13. The light emitting by UVC lamp might cause aging effect. Once it is powered ON, please
keep away valuable things and dark color things from lamp. Long-time lighting exposure to
valuable and dark color things would cause the color to fade.
14. NON WATER-PROOF, Please DO NOT wash by using water. DO NOT place the lamp in rain.
15. During sterilization, please make sure humans and animals must get out from the place.
16. The tubes on the UVC lamp are easily replaceable.
WARNING!
THE DISINFECTION LAMP EMITS UVC AND OZONE. DURING THE WORKING OF THE LAMP,
HUMAN AND ANIMAL MUST GET OUT FROM THE PLACE. AVOID LOOKING DIRECTLY INTO
THE LIGHT. AFTER STERILIZATION IT IS ADVISED TO VENTILATE THE PLACE FOR 20-30
MINUTES. THE LAMP EMITS OZONE, INTENSE EXPOSURE OF WHICH IS HARMFUL.

Chat with your V-Tac 38W UV-C Germicidal Lamp with Ozone manual using AI

Get instant AI answers from your V-Tac 38W UV-C Germicidal Lamp with Ozone manual

Ask anything about the V-Tac 38W UV-C Germicidal Lamp with Ozone. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend 38W UV-C Germicidal Lamp with Ozone?

Yes No

Frequently Asked Questions

A

The lamp runs for exactly 30 minutes per cycle thanks to its built-in timer. You can also manually turn it off sooner by pressing the touch switch or unplugging it.

Is this answer helpful?

A

No. Humans and animals must leave the room immediately after turning the lamp on. Exposure to UVC light and ozone can cause serious health issues including skin burns and eye damage.

Is this answer helpful?

A

This V-Tac lamp is designed to effectively cover indoor spaces up to 60 square meters. It provides 360-degree sterilization to ensure no corners are missed.

Is this answer helpful?

A

Yes. After the 30-minute cycle, you must ventilate the area for 20 to 30 minutes. The lamp emits ozone, which is harmful if inhaled in high concentrations.

Is this answer helpful?

A

No, this appliance is for indoor use only. It is not waterproof and should not be exposed to rain or moisture.

Is this answer helpful?

A

Unplug the lamp first. Wipe the glass tube gently with a dry cloth. Do not use water, alcohol, gasoline, or harsh chemicals as they may damage the device.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Effective 99.9% kill rate for bacteria, viruses, and molds
  • Covers large areas up to 60 square meters efficiently
  • Includes ozone function for deodorizing hard-to-reach spots
  • Automatic 30-minute timer prevents overexposure
  • Long lifespan of 6,000 hours with replaceable tubes
VS

Disadvantages

  • Requires all people and pets to leave the room during operation
  • Emits toxic ozone requiring ventilation after use
  • Not waterproof and cannot be cleaned with water
  • May cause fading of dark-colored or valuable objects
  • Cannot be repaired by unqualified individuals
M: QW-35-FL

Product Specification

Type

Stationary lamp

Method

Ozone, UV

Time programs

30 min

Lamp type

Fluorescent lamp

Power supply

Mains operation

Power consumption

38 W

Color

Black

External dimensions

5.51x17.20x5.91 in (WxHxD)

Weight

1.76 lb

M: QW-35-FL

Product Description

Discover the V-Tac 38W UV-C Germicidal Lamp with Ozone

The V-Tac 38W UV-C Germicidal Lamp with Ozone for 60m2 is a powerful solution designed to sanitize indoor environments effectively. This specialized lamp emits short-wave ultraviolet C light, which disrupts the DNA of bacteria, viruses, and protozoa, leading to their inactivation. The device features a 36-watt UVC quartz tube that ensures a kill rate exceeding 99.9% for various pathogens. Additionally, it generates ozone, a gas with strong oxidizing properties that helps deodorize and clean hard-to-reach areas, making it ideal for comprehensive sterilization.

Designed for spaces up to 60 square meters, this lamp offers 360-degree coverage, perfect for homes, factories, restaurants, hospitals, and schools. It operates on a standard 220-240V power supply and includes a convenient touch switch. Upon activation, the lamp waits ten seconds before turning on, indicated by an audible signal. A built-in timer automatically shuts off the unit after 30 minutes, though users can manually turn it off earlier if needed. The tubes are easily replaceable, ensuring long-term usability with a lifespan of up to 6,000 hours.

Safety is paramount when using this device. Because it emits harmful UVC radiation and ozone, humans and animals must vacate the area during operation. Direct exposure to the light can cause skin irritation and eye damage. After the cycle completes, it is crucial to ventilate the room for 20 to 30 minutes to disperse any remaining ozone. The lamp should never be used outdoors or in wet conditions as it is not waterproof. Regular cleaning with a dry cloth is recommended to maintain efficiency, avoiding chemicals like alcohol or gasoline.

Important Safety Notes

Always read instructions before use. Do not look directly at the light. Keep valuable and dark-colored items away from the lamp to prevent fading due to UV exposure. Only qualified professionals should attempt repairs.

M: QW-35-FL

© Copyright 2026 Manual.ly