bccde3baa7c884a59774b30049ed62aedb26 page 13
12) Indicator Light
Description
<36V
50V~1000V (the red indicator light flashes from slow to fast)
OL
No continuity (≥70Ω)
Continuity (<50Ω)
>2V
Breakdown (<0.12V)
Conduction (0.12V~2V)
≤1000V
>1000V
≤10A
>10A
The temperature in the meter drops to <40°C
after measurement of large current.
The temperature in the meter is ≥75°C
after measurement of large current.
Status
Off
On, red
Off
On, red
On, green
Off
On, red
On, green
Off
On, red
Off
On, red
Off
On, yellow
Function
NCV
Continuity
Diode
AC/DC
voltage
Current
Internal
temperature
during AC/DC
current
measurement
Warning: Before opening the rear cover or battery cover of the meter,
switch off the power supply and remove the test leads.
1. General Maintenance
2. Battery/Fuse Replacement (Picture 18b)
The contents of this manual are subject to change without prior notice.
Picture 18a
Picture 18b
X. Maintenance
RANGE
10A ≤1Ω≤1Ω
OL
OL
√
х
≤20MΩ
mAµA
35
36
1) Clean the meter casing with a damp cloth and mild detergent. Do not use
abrasives or solvents!
2) If there is any malfunction, stop using the meter and send it for maintenance.
3) The maintenance and service must be implemented by qualified professionals
or designated departments.
4) Resistance measurement can be used to check the built-in 600mA and 11A
fuses. Operation (Picture 18a): Insert the red test lead into the or
terminal.Insert the red probe into the mA/μA input terminal to measure the
resistance. If the LCD displays “OL”, the 600mA fuse is blown. Insert the red
probe into the A input terminal to measure the resistance. If the LCD displays
“OL”, the 11A fuse is blown.
Battery: 4×1.5V AAA batteries
Fuse: F1 Fuse 600mA 1000V Φ6x32mm (mA/μA input terminal)
F2 Fuse 11A 1000V Φ10x38mm (A input terminal)
When “ ” is displayed, please replace the batteries in time to ensure
measurement accuracy.
Replacement steps:
1) Turn the function dial to the "OFF" position, and remove the test leads.
2) Unscrew and remove the battery cover to replace the batteries and fuses.

Chat with your UNI-T UT161E manual using AI

Get instant AI answers from your UNI-T UT161E manual

Ask anything about the UNI-T UT161E. Answers come from this manual, with the pages they are based on.

UT161E Maintenance Schedule

Remind me when maintenance is due
Yearly
Verify meter operation before use

Before each use, verify meter operation by measuring a known voltage to ensure accuracy.

When displayed
Replace batteries when low battery icon appears

When the low battery symbol is displayed, replace the 4x1.5V AAA batteries in time to ensure measurement accuracy.

Show in the manual (page 13)
As needed
Clean the meter casing

Clean the meter casing with a damp cloth and mild detergent. Do not use abrasives or solvents.

Show in the manual (page 19)
As needed
Check and replace fuses if malfunction occurs

Use resistance measurement to check built-in fuses; if OL displays, the fuse is blown and must be replaced.

Show in the manual (page 19)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend UT161E?

Yes No

Frequently Asked Questions

A

The UT161E provides a 22000-count main display with ranges for mV, V, μA/mA/A, resistance, capacitance up to large mF ranges, frequency up to 10 kHz, and temperature (on related variants). Specific resolution and accuracy depend on each range; consult the range table for details.

Is this answer helpful?

A

Yes. The meter is designed to IEC 61010-1 standards and rated CAT III 1000V / CAT IV 600V with fused current inputs and overload protection. Always follow safety instructions, use proper test leads, and never exceed rated input voltages to avoid hazards.

Is this answer helpful?

A

The UT161E provides True RMS measurement up to specified frequency limits (up to 10 kHz). Accuracy on non-sinusoidal waves depends on crest factor; additional error percentages are noted for higher crest factors, so account for those when measuring distorted signals.

Is this answer helpful?

A

Use the dedicated hFE dial position and adapter socket to measure transistor magnification (UT161E). For diode tests, select the diode mode and probe anode/cathode; forward voltage is displayed and continuity/diode beeps indicate results.

Is this answer helpful?

A

Insert the red lead into the proper mA/μA or A terminal and ensure fuses are intact. Do not connect current measurements in parallel, use maximum range if unknown, and observe time limits (>5A measurements should be ≤10s with cooling intervals to prevent fuse or thermal tripping).

Is this answer helpful?

A

Yes. The meter supports USB data transmission using a communication module inserted into the USB port and companion software available from the manufacturer. Data transmission can be toggled on/off via a long-press button or by removing the module.

Is this answer helpful?

A

Regularly inspect leads and casing for damage, replace batteries when the low-battery icon appears, and check/replace the 600 mA and 11 A fuses if blown. Clean with a damp cloth, avoid solvents, and send the unit to qualified service personnel for repairs.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • 22000-count display with True RMS for high-resolution, accurate AC measurements up to 10 kHz.
  • Comprehensive feature set: AC/DC volts/amps, mV, resistance, capacitance, frequency, duty, diode, continuity, hFE, peak/max-min, NCV and USB data.
  • Strong safety: IEC 61010-1, CAT III 1000V/CAT IV 600V rating, fused inputs and overload protection.
  • User-friendly design: large LCD with bargraph, backlight, data hold, REL mode, auto/manual range and tilt stand.
  • Portable power and accessories: runs on 4×AAA batteries; includes test leads, USB cable and adapter options.
VS

Disadvantages

  • Large-count True RMS performance may need crest-factor corrections and has additional error for non-sinusoidal waves.
  • Some advanced functions (temperature, LoZ) depend on model variants and optional accessories.
  • High-current measurements limited by fuse protection and duty cycle (≤10s at >5A with cooling intervals).
  • Accuracy specifications vary by range and frequency; users must consult range-specific accuracy tables for critical work.
  • Heavy reliance on correct probe wiring and fuse integrity—misuse can risk damage or safety hazards.
M: OA-GPT-5-NAN

Product Specification

Measurement Range

20A, max. 1000V, 220MΩ

M: OA-GPT-54-NAN

Product Description

UNI-T UT161E True RMS Digital Multimeter — Precision in Your Hands

The UNI-T UT161E True RMS Digital Multimeter is a high-resolution, feature-rich handheld meter designed for professional electricians, technicians, and advanced hobbyists. Offering a 22000-count display, True RMS measurement and an extensive range of functions, the UT161E delivers accurate readings across AC/DC voltage and current, resistance, capacitance, frequency, duty cycle, diode/transistor tests, and more. Ergonomically built with a large LCD, high-resolution analog-style bargraph, backlight, non-contact voltage (NCV) detection, and USB data connectivity, this model balances portability with laboratory-grade functionality.

Built to strict safety standards (IEC 61010-1) and certified for CAT III 1000V/CAT IV 600V environments, the UT161E emphasizes user protection with full-scale overload safeguards, fused current inputs and clear input-wiring warnings. Practical features such as auto/manual ranging, data hold, relative (REL) mode, peak and max/min capture, low-battery indicator, auto power-off and audible/visual alarms for extreme conditions make routine diagnostics and troubleshooting faster and safer.

The meter supports AC+DC and True RMS readings over wide frequency ranges (up to 10 kHz), with selectable low-pass filtering and LoZ functions on related models to suppress ghost voltages. Dedicated transistor hFE testing (via an adapter), capacitance measurement up to large mF ranges, and peak measurement capability expand its utility for electronics, power systems and component testing. USB connectivity and optional data transmission let you log and analyze measurements on a PC when required.

Ergonomics and durability are addressed with guarded input terminals, insulated test-lead slots, tilted stand, clear indicator LEDs for NCV, continuity/diode results and internal-temperature warnings when high current causes heating. The package typically includes test leads, USB cable and, depending on variant, an adapter socket and thermocouple; powered by four AAA batteries for convenient field use.

Overall, the UNI-T UT161E pairs robust safety credentials and professional-level measurement performance in a compact, user-friendly instrument—well suited to HVAC, automotive electronics, industrial maintenance and electrical troubleshooting.

Notes

  • Always observe safety guidance: disconnect power for resistance/capacitance/diode tests and use the correct input terminals for current measurements.
  • Max rated input is 1000 V; exceeding this triggers audible and visual alarms and may show OL.
  • Replace batteries when low-battery icon appears and check fuses before current measurements.