The Xtra 3000 Fi and 6000 Fi  lter pumps are high-quality products which correspond to the latest state-of-the-art. The pumps are  tted with a reliable, powerful yet
economic asynchronous motor and ceramic shaft. The pumps have been specially designed for use as  lter pumps.
Safety regulations
• The power supply must correspond to the product speci cations. In case of doubt, ask your local utility about the connection rules. Do not connect the pump or the power cable if
they do not conform to the stated rules!
• For reasons of European safety standards, the pump must always be connected to a shockproof socket. The power circuit must contain a residual current circuit breaker
(r.c.c.b./30mA). Your local electrical specialist can provide you with further information.
• The pump is not suitable for use in swimming pools, swimming ponds or other bodies of water in which people could be present. It may therefore not be deployed for such a
purpose.
• Do not use the cable to carry the pump or to pull the pump out of the pond.
• Never remove the plug by cutting it off the connecting cable and never shorten the connecting cable. If you do so, your guarantee claim will be invalidated!
• Make sure that the plug and socket are dry before use.
• Make sure that the power is switched off before starting any maintenance work on the pond or before cleaning the pump.
• This pump has been designed to pump water at a temperature of at least 4°C up to a maximum 35°C.
• Do not allow the pump to run dry. This can cause irreparable damage.
• This device is not suitable for use by people (including children) with reduced physical, sensory or mental capabilities or who lack experience and/or knowledge, unless they are
supervised by a person responsible for their safety or have been instructed in how to use the device. Children must be supervised to ensure that they do not play with the device.
• The power cable cannot be replaced. If the connecting line is damaged, the pump must be taken out of operation and disposed of in order to prevent dangers.
General warnings
Some packaging parts can pose a hazard (e.g. plastic bags), these must therefore be kept out of the reach of children and domestic pets.
Use
The pumps are suitable for use in ponds and in combination with  lter systems.
Getting started
Please read the instructions for use carefully
Never let the pump run dry, i.e. operation without water running through it
Install the pump at least 30 cm to a maximum 100 cm below the surface of the water on a stable base which is free form mud, slime and other soiling
Screw the socket piece supplied onto the pump's pressure nozzle
Cleaning and maintenance
The pump requires neither lubrication nor any special maintenance work. Simply check from time to time that the inlet slits in the protective cap on the pump housing are free of
soiling. If these have become clogged, clean them out with clean water.
In case the pump has become more heavily soiled, the pump housing should be cleaned. To do so, you will  rst need to take it apart:
1. Remove the hose connection with the hose socket piece and double sleeve.
2. Take the protective cap off the pump housing (Fig.1)
3. Undo the screws in the pump housing and lift this away from the motor section (Figs. 2+3). Then pull the rotor element out of the motor (see Figs. 4+5) You can now clean the
motor and rotor parts.
4. After cleaning, reassemble the pump in the reverse sequence.
How often such cleaning is necessary depends on the particular conditions of use and how soiled your pool is.
In Winter, make sure that the pump does not become frozen in. You should therefore take the pump out of the pond in good time, clean it and keep it in a place safe from frost, for
example in a bucket of water.
Cleaning/exchanging the rotor
Clean the rotor with a soft cloth. Never use a (chemical) cleaning agent.
Avoid contact with the ceramic axle so as not to damage this.
Please note: The 8 screws in the motor section may not be undone. If you remove these screws, the guarantee claim will be invalidated.
Guarantee
We guarantee this product for 2 years against proven material and manufacturing faults from the date of purchase. The original purchase receipt must be presented as proof of
purchase in case of guarantee claims. The guarantee does not extend to complaints caused by assembly or operating errors, a lack of care, the eff ects of frost, improper repair attempts,
the use of force, outside culpability, overloads, mechanical damage or the eff ects of foreign bodies. The guarantee likewise excludes all complaints concerning parts damage and/or
problems caused by wear and tear.
1
Instructions of use for Xtra 3000 Fi and Xtra 6000 Fi  lter pumps
The Xtra 3000 Fi and 6000 Fi  lter pumps are high-quality products which correspond to the latest state-of-the-art. The pumps are  tted with a reliable, powerful yet
economic asynchronous motor and ceramic shaft. The pumps have been specially designed for use as  lter pumps.
Safety regulations
Correct disposal of this product
In the EU, this symbol shows that this product may not be disposed of with the domestic refuse. Old devices contain valuable materials that can be recycled. They should
therefore be taken to your local collection point to be recovered and to avoid pollution of the environment or harm to human health through uncontrolled dumping of
rubbish. If there are no suitable disposal systems available near you, please return the old device to the place you purchased it so it can be taken for recycling from there.
Use
The pumps are suitable for use in ponds and in combination with  lter systems.
2
xtra Fi manual 2012-2.indd 1 20-11-12 10:31

Chat with your Ubbink Xtra 2300 manual using AI

Get instant AI answers from your Ubbink Xtra 2300 manual

Ask anything about the Ubbink Xtra 2300. Answers come from this manual, with the pages they are based on.

Xtra 2300 Maintenance Schedule

Remind me when maintenance is due
Yearly (Winter)
Store pump frost-free in winter

In winter, remove the pump from the pond, clean it, and store it in a place safe from frost, such as in a bucket of water.

Periodically
Check and clean inlet slits of protective cap

Check from time to time that the inlet slits in the protective cap are free of soiling. If clogged, clean them out with clean water.

As needed
Clean pump housing if heavily soiled

If the pump is heavily soiled, disassemble the housing to clean motor and rotor parts. Frequency depends on usage conditions and pond dirtiness.

Soft cloth only
Clean rotor with soft cloth

Clean the rotor with a soft cloth. Never use chemical cleaning agents. Avoid contact with the ceramic axle to prevent damage.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend Xtra 2300?

Yes No

Frequently Asked Questions

A

No, the Ubbink Xtra 2300 is not suitable for use in swimming pools, swimming ponds, or any body of water where people are present. It is designed strictly for ponds and fountains.

Is this answer helpful?

A

Install the pump at least 30 centimeters and no more than 100 centimeters below the water surface on a stable base that is free from mud and slime.

Is this answer helpful?

A

No, the pump requires neither lubrication nor special maintenance work. You only need to occasionally check and clean the inlet slits on the protective cap.

Is this answer helpful?

A

The power cable cannot be replaced. If the connecting line is damaged, the pump must be taken out of operation and disposed of to prevent safety hazards.

Is this answer helpful?

A

No, you must remove the pump from the pond in good time during winter to prevent it from freezing. Clean it and store it in a frost-safe place, such as a bucket of water.

Is this answer helpful?

A

This pump is designed to pump water at temperatures ranging from a minimum of 4 degrees Celsius up to a maximum of 35 degrees Celsius.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Powerful asynchronous motor ensures reliable and efficient water circulation.
  • Durable ceramic shaft reduces wear and extends the lifespan of the pump.
  • Low maintenance requirements with no need for lubrication.
  • Versatile design suitable for both ponds and fountain applications.
  • Comes with a comprehensive 2-year manufacturer guarantee.
VS

Disadvantages

  • Cannot be used in swimming pools or areas where people are present in the water.
  • Power cable is non-replaceable, requiring full disposal if damaged.
  • Must be installed between 30cm and 100cm deep, limiting shallow setups.
  • Requires careful winter storage to prevent freezing damage.
  • Warranty is voided if internal motor screws are removed during service.
M: QW-35-FL

Product Specification

Power

35W

Flow rate

608.42 gal/h

Pressure connection

1/2"

Suction connection

1/2"

Features

no tank, fountain (7.22 ft)

M: QW-35-FL

Product Description

Discover the Power of the Ubbink Xtra 2300 Electric Fountain Pump

Transform your garden water feature with the Ubbink Xtra 2300 Electric Fountain Pump. This high-quality filter pump is designed to meet the latest state-of-the-art standards, ensuring reliable performance for your pond or fountain. Equipped with a powerful yet economical asynchronous motor and a durable ceramic shaft, this pump delivers efficient water circulation while maintaining energy efficiency.

The Xtra series is specifically engineered for use in ponds and fountains, making it an ideal companion for various filtration systems. Its robust construction ensures longevity, while the ceramic shaft provides smooth operation and reduced wear over time. Whether you are looking to create a serene fountain display or maintain crystal-clear pond water, this pump offers the versatility and power you need.

Installation is straightforward when following the recommended guidelines. Place the pump at least 30 centimeters but no more than 100 centimeters below the water surface on a stable base free from mud and slime. The pump operates safely within a water temperature range of 4°C to 35°C, making it suitable for year-round use in most climates, provided it is protected from freezing conditions during winter.

Maintenance is minimal, requiring no lubrication. Simply check the inlet slits on the protective cap periodically and clean them with fresh water if clogged. For deeper cleaning, the pump housing can be disassembled to access the rotor and motor components. Remember never to use chemical cleaning agents on the rotor and avoid contact with the ceramic axle to prevent damage.

Safety is a top priority with this device. It must always be connected to a shockproof socket equipped with a residual current circuit breaker (R.C.C.B./30mA). Never run the pump dry, as this can cause irreparable damage. Additionally, the power cable cannot be replaced; if damaged, the entire unit must be disposed of safely. This pump is not intended for use in swimming pools or bodies of water where people swim.

With a two-year guarantee against material and manufacturing faults, the Ubbink Xtra 2300 offers peace of mind. Always keep the original purchase receipt for any warranty claims. Proper disposal of the product is essential; do not discard it with household waste but take it to a recycling point to recover valuable materials.

Important Notes

  • Do not remove the plug by cutting the cable, or your warranty will be voided.
  • Ensure the plug and socket are dry before connecting power.
  • Store the pump in a frost-free location during winter, ideally in a bucket of water.
M: QW-35-FL

© Copyright 2026 Manual.ly