4. User instructions
The device must be filled with water before being connected to the electrical supply!
The device should always be connected to a 0.8 MPa pressure relief valve (8)!
If the water in the boiler is heated, the volume will increase. This is referred to as expansion water. The ex-
pansion water will drip away via the pressure relief valve. This is necessary and should not be prevented.
5. Maintenance
This device does not require any maintenance by the user. Professional maintenance should always be car-
ried out by an expert.
The pressure relief valve discharges expansion water through its funnel. This funnel must be placed in a
continuous downward direction and must always be left open to the atmosphere. A discharge hose is placed
between the funnel and sewer. This construction must always be placed in a frost-free environment.
Check the functioning of the pressure relief valve by turning the large knob on the pressure relief valve once
a year, allowing water to flow out, and closing it immediately. This will prevent the valve of the pressure re-
lief valve from getting stuck. Also check the drain for blockages. If it is blocked, unblock the drain or instruct
a third party to do so.
If you have a complaint or a technical defect, please do not try to repair the device yourself. Contact
Thermoflow customer service at: [email protected] or Tel .: 0355-493 88 50.
Alternatively, please contact your dealer.
Cleaning
The housing of the device can simply be cleaned with a damp cloth. Do not use aggressive cleaners or
cleaners with a scouring effect!
Legislation prevention
Do not use heated water as drinking water. After prolonged shutdown of the device for example due to holi-
days, the device should be fully heated up to the maximum temperature before re-using. It is recommended
to flush the pipes for one minute.
6. Troubleshooting
Note: in case of problems, always consult the troubleshooter!
If the water in the device is no longer heated, first check whether the plug is properly connected to the wall
socket and whether the fuse of the device group is still working. For all other failures, please consult the
troubleshooter on page. 17.
If the device no longer works because it was connected without being filled with water first, follow the trou-
bleshooter. The device has been overheated and needs to cool down, or possibly repaired.
If the device has been reset several times but still does not work, contact the device customer service or
your dealer.
manual storage boiler u2 5L.indd 31manual storage boiler u2 5L.indd 31 2021/1/26 10:302021/1/26 10:30

Chat with your Thermoflow 100E manual using AI

Get instant AI answers from your Thermoflow 100E manual

Ask anything about the Thermoflow 100E. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend 100E?

Yes No

Frequently Asked Questions

A

The boiler can be set to heat water to a maximum of either 70°C or 100°C. When used with the mixing valve, hot-water output can be adjusted: 30–55°C with the boiler at 100°C, and 30–50°C with the boiler at 70°C.

Is this answer helpful?

A

Yes—if your water hardness exceeds 10°dH the manual recommends using an additional filter to reduce limescale buildup. The inlet and outlet of a recommended filter should be G3/8”. The filter is not included with the unit.

Is this answer helpful?

A

The device should be installed by qualified personnel following the provided instructions. Incorrect installation, use of non-original parts, or unauthorized repairs can damage the unit and void the warranty.

Is this answer helpful?

A

Always fill the boiler with water first, open the boiling and hot-water valves to purge air from the system, then plug the unit into a properly rated 230V grounded outlet. Never power the unit when empty.

Is this answer helpful?

A

To dispense boiling water, push in the safety catch then turn the boiling-water knob away from you; it is spring‑loaded to return to its off position, preventing accidental activation and enhancing child safety.

Is this answer helpful?

A

User maintenance is minimal: wipe the housing with a damp cloth and avoid aggressive cleaners. Annually operate the large pressure-relief valve knob to avoid sticking and check the drain hose for blockages. Descaling and internal service must be performed by authorized technicians.

Is this answer helpful?

A

The manufacturer provides a 24-month warranty against material and manufacturing defects, starting from purchase. The warranty excludes damage from improper installation, misuse, normal limescale wear, unauthorized repairs, and problems from extreme water chemistry (pH, chlorine, iron levels outside specified limits).

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Instant boiling and adjustable hot water from one compact 5 L unit, ideal for kitchens and small commercial use.
  • Child-safe tap design with spring‑return boiling-water knob and clear LED temperature indicators.
  • Selectable boiler temperatures (70°C or 100°C) and adjustable mixed hot-water range when using the mixing valve.
  • Simple user maintenance: exterior cleaning and an annual pressure-relief valve check; major work by authorized service.
  • Compliant with EU safety and EMC standards and covered by a 24-month manufacturer warranty (subject to conditions).
VS

Disadvantages

  • Requires professional installation and correct positioning close to a cold-water connection; improper install voids warranty.
  • Not suitable for RO or pH-reducing water-softening systems; extreme water chemistry voids warranty coverage.
  • Sensitive to limescale—filter recommended in hard-water regions (>10°dH) and descaling requires qualified service.
  • Must always be filled with water before powering; overheating from dry power-up may require repair.
  • Pressure relief drain must be routed and kept frost-free; improper drainage can cause odors or function issues.
M: OA-GPT-5-NAN

Product Specification

Energy efficiency class

A

Energy consumption

498kWh

Rated power

2.2kW (230V)

Rated current

9.6A

Fuse protection

16A

Temperature control

59-212°F

Capacity

1.32 gal

Type of construction

open

Mounting type

Undersink mounting

Connection

1/2"

Display

no

Protection class

IP24

Noise emission

15dB

Dimensions

8.27x17.83x8.27in (WxHxD)

Weight

19.84 lb

M: OA-GPT-54-NAN

Product Description

Thermoflow 100E Boiling Water Appliance Hot Water Storage

The Thermoflow 100E combines a compact 5 L boiling-water boiler with a 3-in-1 tap, delivering instant boiling water plus adjustable hot water for kitchens and small commercial settings. Engineered for safety and convenience, the unit offers selectable boiler temperatures (70°C or 100°C), child-safe tap controls, and a professional mounting kit for secure installation near a cold-water connection.

Installation is intended for qualified personnel and follows clear step-by-step procedures: connect the 3-in-1 tap, fit the pressure relief valve and waste hose correctly, choose between two plumbing variants (with or without an external hot-water house connection), fill the boiler with water first, then plug in the unit, and set the desired temperature. The manual recommends installing a filter where water hardness exceeds 10°dH to minimize limescale and prolong service life.

Daily operation is straightforward. The tap provides cold, hot, or boiling water via separate controls: a lever for hot/cold mixing and a spring‑return safety knob for boiling water. The boiler’s LED indicates standby and heating status; touch-buttons allow switching between standby, 70°C and 100°C modes. When used with the optional mixing valve, hot water output can be set within defined ranges (30–55°C at 100°C boiler setting; 30–50°C at 70°C setting).

Maintenance needs are minimal for the user: wipe the housing with a damp cloth and avoid aggressive cleaners. Annual checks include operating the pressure relief valve knob to prevent sticking and inspecting the drain for blockages. Major maintenance tasks (descaling, internal repairs) must be done by authorized technicians to preserve warranty.

Safety and compliance are emphasized: never power the unit before filling with water, ensure the pressure relief valve funnel is pointed downward and routed correctly, protect the device from frost, and avoid external switching devices (timers) that repeatedly cycle power. The product conforms to multiple EU directives and harmonized standards and includes a 24-month manufacturer warranty covering material and manufacturing defects (with exclusions for incorrect installation, misuse, scaling, or extreme water chemistry).

Notes:

  • Always fill the boiler before connecting to mains power.
  • Install a filter if water hardness >10°dH.
  • Keep the relief valve funnel unobstructed and routed to drainage.
  • Warranty voids if non‑original parts are fitted or unauthorized repairs attempted.