184582f3570d93830e958736e078f6c744d1 page 1
MFP8 IE Cat.6
A
/ PROFINET AWG24-22/1, AWG27-22/7; MFP8 IE Cat.6
A
AWG26-24/1, AWG27-24/7
Montagehinweis / Mounting information
D B05030A0423 18.11.2015© by Telegärtner
Telegärtner Karl Gärtner GmbH • Lerchenstr. 35 • D-71144 Steinenbronn • Tel.: +49 (0)7157/125-100 • Fax: +49 (0)7157/125-120 • E-Mail: info@telegaertner.com • www.telegaertner.com
0 15
80
5 50
mm
Adernmanager weiß
für Ø1,0 - 1,6 mm
wire manager white
for Ø0.039-0.063 in.
Adernmanager weiß
für Ø1,0 - 1,6 mm
wire manager white
for Ø0.039-0.063 in.
Lieferumfang / Scope of delivery
Adernmanager grau
für Ø 0,85 - 1,1 mm
wire manager grey
for Ø0.033-0.043 in.
2a
3
2b 2c
2d
21
Kabelverschraubung aufschieben
slide cable gland onto cable
Klemmkäfig / clamping ring
Abisolierlänge / Stripping length
fold braid shield backwards
Geflechtschirm nach hinten legen
S/FTP
U/FTP
Adernpaare entdrillen
untwist pair
s
Adernpaare vorsortieren
Kabelseite 1 cable end 1
Kabelseite 2 cable end 2
T568A T568B
Adernpaare in den Adernmanager einführen
insert pairs into the wire manager
min. 50 mm / min. 2 in.
Beilaufdraht gewickelt
Drain wire wrapped
Anschluss / Connection Anwendung/Application
Farbcode
Colour code
T568
PROFINET
RJ45 PIN
Nr./No.
10BT/
100BT
1 Gigabit/
10 Gigabit
Ethernet
Token
Ring
ISDN/So
Upo/
TEL
A B
W - G W - O YE
1
• •
G O O
2
• •
W - O W - G W
3
• • •
BL BL -
4
• •
•
W - BL W - BL -
5
• •
•
O G BL
6
• • •
W - BR W - BR -
7
•
BR BR -
8
•
Geflechtschirm gleichmäßig um den Kabelmantel
drehen/wrap braid shield evenly around cable jacket
min. 50 mm
min. 2 in.
N00000A0013
Zangenschlüssel
Plier-Wrench 1 3/8“
Parallel Presswerkzeug
Parallel Press Tool
N00000B0020
remove assembly aid
Montagehilfe entfernen
Alle Adern bündig
abschneiden, max. 0,5 mm
überstehend
cut all wires protruding max. 0.02 in.
0.2 in.5 mm
max.
10 mm
max.
0.4 in.
presort pairs
4
min. 50 mm / min. 2 in.
max. 0.4 in.
max. 10 mm
ohne Klemmkäfig ab Ø > 8 mm
without clamping ring for Ø > 0.3 in.
5
S/SFTP
Trennkreuz abschneiden
cut off cross separator
Sorgfältige Glättung der Einzeladern vor dem
Einführen in den Adernmanager
smooth wires accurately
before inserting into the wire manager
min. 80 mm / min. 3.15 in.
untwist pairs and smooth wires accurately
insert pairs into the wire manager
SF/UTP
Adernpaare entdrillen und Einzeladern sorgfältig glätten
Adernpaare in den Adernmanager einführen

Chat with your Telegartner MFP8 IE Cat.6A manual using AI

Get instant AI answers from your Telegartner MFP8 IE Cat.6A manual

Ask anything about the Telegartner MFP8 IE Cat.6A. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend MFP8 IE Cat.6A?

Yes No

Frequently Asked Questions

A

This connector is designed for Category 6A standards and supports speeds up to 10 Gigabit Ethernet. It ensures reliable high-speed data transmission in modern networks.

Is this answer helpful?

A

It supports AWG 24-22/1, AWG27-22/7, and AWG26-24/1, AWG27-24/7 cable types. The design accommodates both stranded and solid wire configurations effectively.

Is this answer helpful?

A

Yes, installation requires tools such as a plier-wrench and a parallel press tool. These ensure the cable gland is tightened correctly without damaging components.

Is this answer helpful?

A

The braid shield must be wrapped evenly around the cable jacket and bent back. Pay attention to the position to ensure proper grounding and signal integrity.

Is this answer helpful?

A

Maximum protrusion of wires should not exceed five millimeters. This ensures internal safety and proper connection within the terminal block.

Is this answer helpful?

A

The manufacturer is Telegartner Karl Gartner GmbH based in Steinenbronn, Germany. They are known for high-quality industrial connectors.

Is this answer helpful?

A

Yes, it supports T568A, T568B, and PROFINET color codes. This versatility allows flexibility in various networking setups.

Is this answer helpful?

M: qwen/qwen3.5-flash-20260224

Advantages and Disadvantages

Advantages

  • Supports 10 Gigabit Ethernet performance
  • Field-terminatable for on-site installation
  • Compatible with PROFINET and Ethernet standards
  • Uses wire manager for pair organization
  • High quality from established German manufacturer
VS

Disadvantages

  • Requires specific tools like plier-wrench
  • Precise stripping lengths needed for safety
  • Multiple color codes must be memorized
  • Cable gland tightening requires torque control
  • Assembly aid removal can be tricky
M: qwen/qwen3.5-flash-20260224

Product Description

Telegartner MFP8 IE T568 A RJ-45 Cat6a Modular Connector Overview

The Telegartner MFP8 IE T568 A RJ-45 Cat6a Modular connector offers a robust solution for high-speed networking installations in demanding environments globally. This field-terminatable connector allows technicians to assemble connections on-site without relying on pre-terminated cables entirely. Designed for Category 6A performance, it supports speeds up to 10 Gigabit Ethernet reliably. The unit features a specific wire manager system to organize pairs efficiently within the housing structure. Installation requires precise stripping lengths of at least fifty millimeters to ensure proper contact points. Technicians must use specific tools like a plier-wrench to secure the cable gland effectively.

The connector handles multiple standard color codes including T568A, T568B, and PROFINET configurations. This versatility makes it ideal for industrial automation where reliability is paramount and standards vary. The braid shield must be managed correctly to ensure signal integrity during termination procedures. Proper alignment of the internal pairs prevents crosstalk and maintains high data throughput levels. The clamping ring secures the cable jacket firmly against strain and environmental factors. Users should follow the step-by-step procedure for best results every time. Smooth wires ensure better contact within the terminal block and reduce resistance significantly. The cross separator removal is a key step in the process to reduce bulk inside.

This equipment fits diverse cable diameters ranging from 0.85 to 1.6 millimeters accurately. It supports stranded and solid wire types effectively for flexibility and durability in use. The AWG specifications cover a wide range from 24 to 27 depending on the specific model configuration chosen. Field installation becomes easier with the included wire manager guides for white or grey options. The housing allows for tight cable gland tightening to protect internal components from damage. Overall, this connector simplifies complex field terminations significantly for network teams and technicians. It ensures compliance with various networking protocols while maintaining physical robustness. The design supports both PROFINET applications and standard Ethernet setups without compromise.

Safety and performance remain central to the engineering design of this component. Additional tools such as a parallel press tool facilitate the assembly process efficiently. The wire manager can be brought to the end position by means of screen covers included in the kit. Technicians must cut the filler inside the cable to prepare the pairs correctly. Stripping the inner jacket and foil screen requires care to avoid damaging conductor strands. The drain wire must be wrapped evenly around the cable shield for grounding purposes. Maximum protrusion of wires should not exceed five millimeters for safety reasons. Removing the assembly aid reveals the ready-to-use connection points clearly on the device. The product is manufactured by Telegartner Karl Gartner GmbH based in Germany. They have established a reputation for high-quality industrial connectors over many years.

The cable gland tightening requires approximately one Newton meter of torque for security. Half shells must be pressed together tightly to enclose the components. This attention to detail ensures long-term operational stability under stress conditions. Network administrators appreciate the clarity of the color codes provided on the pinout diagram. Whether using fiber optic shielding or copper wiring, this unit adapts well effectively. The scope of delivery often includes the necessary wire managers for different cable sizes. Installation time is reduced compared to soldering methods for legacy equipment types. Modern networks demand speed and consistency which this connector delivers daily. It serves as a critical interface point in structured cabling infrastructure projects regularly.