114
Alarm ID Alarm Name Corrective Measures
010
Grid Power
Outage
Generally, the inverter will be reconnected to the grid
after the grid recovers. If the alarm occurs frequently:
1. Check whether the grid supplies power reliably.
2. Check whether the AC cable is firmly in place.
3. Check whether the AC cable is correctly connected
(whether the live wire and the N wire are in correct
place).
4. Check whether the AC switch or circuit breaker is
disconnected.
5. If the alarm persists, contact SUNGROW.
012
Excessive leak-
age current
1. The alarm can be caused by poor sunlight or damp
environment, and the inverter will be reconnected to
the grid after the environment is improved.
2. If the environment is normal, check whether the AC
and DC cables are well insulated.
3. If the alarm persists, contact SUNGROW.
013 Grid abnormal
Generally, the inverter will be reconnected to the grid
after the grid recovers. If the alarm occurs frequently:
1. Measure the grid frequency, and contact the local
utility grid company for solutions if the grid frequency
exceeds the specified value.
2. If the alarm persists, contact SUNGROW.
017
Grid voltage
unbalance
Generally, the inverter will be reconnected to the grid
after the grid recovers. If the alarm occurs frequently:
1. Measure the grid voltage. If grid phase voltage dif-
fers greatly, contact the utility grid company for
solutions.
2. If the voltage difference between the three phases
is within the permissible range of the local utility grid
company, modify the parameter setting through the
App.
3. If the alarm persists, contact SUNGROW.
10 Troubleshooting and Maintenance User Manual

Chat with your Sungrow SH RT manual using AI

Get instant AI answers from your Sungrow SH RT manual

Ask anything about the Sungrow SH RT. Answers come from this manual, with the pages they are based on.

SH RT Maintenance Schedule

Remind me when maintenance is due
Quarterly
Check backup battery cell

Inspect the button cell attachment, appearance, voltage, and resistance.

Show in the manual (page 124)
Semiannual
Inspect system condition and electrical connections

Visually check for damage or deformation, listen for unusual noises, verify operating parameters, ensure cooling fins are exposed, and check cables for damage.

Show in the manual (page 124)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend SH RT?

Yes No

Frequently Asked Questions

A

The system is compatible with Sungrow, LG Chem, BYD, and Pylontech lithium-ion batteries. Users must consult the manual for specific voltage thresholds and BMS requirements to ensure safe operation.

Is this answer helpful?

A

The inverter switches to battery backup mode within 20 milliseconds. It prioritizes critical loads connected to the backup terminals, ensuring essential appliances continue running during grid failures.

Is this answer helpful?

A

Yes, up to two hybrid inverters of the same type can operate in parallel. They communicate via RS485 to balance load and optimize energy management between the units.

Is this answer helpful?

A

No, the unit is not recommended for indoor installation in living areas due to operational noise. It is designed for locations that allow for adequate ventilation and noise tolerance, such as garages or utility rooms.

Is this answer helpful?

A

Installers must wear personal protective equipment and ensure DC and AC sources are disconnected before touching terminals. Qualified personnel must handle all electrical connections to prevent injury.

Is this answer helpful?

A

The EMS directs excess solar power to charge the battery first. Once the battery is full, the remaining energy can be exported to the grid up to a limit set in the app.

Is this answer helpful?

A

The inverter supports WiNet-S for wireless connectivity and Ethernet for wired connections. Both methods allow users to monitor status and control settings via the iSolarCloud app.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Seamless integration with multiple battery brands like Sungrow, LG Chem, BYD, and Pylontech.
  • Fast backup switching time of under 20 milliseconds for critical loads.
  • Intelligent Energy Management System prioritizes self-consumption and grid export reduction.
  • Robust safety features including built-in ground fault protection and emergency disconnects.
  • Supports parallel operation of two units to increase total inverter capacity and redundancy.
VS

Disadvantages

  • Installation requires qualified personnel due to high voltage risks and complex wiring.
  • Operational noise levels may make indoor installation unsuitable for living spaces.
  • Backup capacity is limited and cannot power all household loads simultaneously.
  • Requires specific grounding compliance depending on local regional electrical standards.
  • Firmware updates and configuration require specific communication modules like WiNet-S.
M: QW-35-FL

Product Specification

Note

Prices include 0% VAT rates for Austria and Germany in some cases

Type

Hybrid Inverter, Without Transformer, Passive

MPP Tracker Count

2

Output Phases

3-phase

Input

MC4

Interfaces

Wi-Fi (WLAN), 1x RJ-45, 1x RS-485

Sound Level

30 dB

Protection Class

IP65

Ambient Temperature

-13°F to +140°F

Dimensions

18.11 x 21.26 x 6.69 in (W x H x D)

Weight

59.52 lbs

M: QW-35-FL

Product Description

Sungrow SH RT Hybrid Inverter Overview

The Sungrow SH RT series of hybrid inverters marks a pivotal advancement in residential solar energy management, offering seamless integration for homeowners eager to maximize their solar potential while securing reliable power supply. This robust line, featuring models rated from 5.0 kW up to 10.0 kW, is engineered to work harmoniously with photovoltaic arrays and lithium-ion battery storage solutions. The system enables users to transition from standard grid-tied setups to comprehensive hybrid energy management systems. These units can isolate the home during grid outages, providing essential backup power precisely when the utility is unavailable.

Installation is streamlined through intelligent design, utilizing clear terminal blocks and deeply embedded safety mechanisms. The series adheres to international safety standards, requiring qualified personnel to follow strict protocols regarding high voltage handling, proper grounding, and thermal management. The system supports multiple communication protocols, including WiNet-S and Ethernet, allowing for thorough remote monitoring and diagnostics. This connectivity ensures that system health and production metrics are always accessible via the iSolarCloud application.

For professional installers, detailed procedures cover mechanical mounting, electrical connections, and initial configuration phases. It is vital to understand safety warnings regarding DC disconnects, proper grounding, and cable specifications to prevent serious hazards and ensure warranty compliance. The documentation stresses verifying environmental conditions, ensuring adequate ventilation for heat dissipation, and strictly avoiding indoor installation in living areas due to operational noise.

Power management is automated internally via the integrated Energy Management System. This intelligent logic prioritizes self-consumption by directing any photovoltaic surplus to charge batteries rather than exporting it to the grid immediately. When solar generation is insufficient or during nighttime hours, stored energy powers essential loads, with automatic backup switching occurring in under 20 milliseconds. The inverter integrates with battery brands like Sungrow, LG Chem, BYD, and Pylontech, ensuring compatibility with modern storage solutions designed for optimized cycle longevity. The system dynamically adjusts output based on real-time demand, reducing strain on the grid and lowering electricity bills over time. This smart management extends the lifespan of the battery storage system by preventing unnecessary cycling and deep discharge events.

Whether you are retrofitting an existing PV system or designing a new hybrid setup, understanding configuration parameters is crucial. The guidelines detail DRM compliance for regions and specific battery charging optimization strategies. Proper setup of communication lines allows for real-time performance tracking. By adhering to the instructions found in the Sungrow SH RT Manual, installers can guarantee a robust, efficient, and safe energy infrastructure. The system supports parallel operation of two units to increase total capacity and includes protections against islanding, ground faults, and over voltage, making it a comprehensive choice for modern residential energy needs.

The backup function is designed to power critical loads, not all household appliances. Users should connect sensitive medical devices or high-startup current appliances with caution. The unit manages battery states of charge automatically, preventing deep discharge or overcharging, which significantly extends battery life. Advanced features include blind power control and load scheduling, allowing users to tailor consumption to local electricity tariffs. Ultimately, proper installation and configuration unlock the full potential of solar self-consumption and grid independence.