SXUP1000XWE Maintenance Schedule
Sluice the appliance and all external components with clean water. Remove hard deposits with a jet of water to prevent impeller jamming.
Check accessories and inspect the appliance's components for signs of failure or wear before use and at regular intervals.
Ask a Question
Do you recommend SXUP1000XWE?
Yes NoDo you recommend SXUP1000XWE?
Yes NoFrequently Asked Questions
No, the Stanley SXUP1000XWE is not designed for pumping drinking water. The pumped liquid may become contaminated by lubricant leaks from the motor, making it unsafe for human consumption.
Is this answer helpful?
The pump has a maximum immersion depth of 16 meters. It can also achieve a maximum head of 55 meters, meaning it can push water to that height vertically.
Is this answer helpful?
No, this appliance is not suitable for pumping water containing sand, mud, or clay. These abrasive substances can damage the impeller and cause malfunctions.
Is this answer helpful?
Always ensure the pump body is filled with water before starting. Do not let the suction point be closed for more than 10 seconds. If the water level drops, stop the pump immediately to avoid overheating.
Is this answer helpful?
You should use a delivery hose with an internal diameter of at least 25 mm (1 inch). Using a smaller hose will drastically reduce the flow rate and efficiency of the pump.
Is this answer helpful?
No, the appliance does not have a built-in ON/OFF switch. You must connect it to a socket controlled by an external switch to safely turn it on and off.
Is this answer helpful?
The product comes with a 24-month warranty from the date of purchase for household use. Professional sales typically carry a 12-month warranty period covering material defects.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Powerful 1000W motor provides high flow rates suitable for deep wells
- Maximum head of 55 meters allows for significant vertical water lift
- IPX8 protection class ensures safe operation when fully submerged
- Compact structure fits into narrow wells starting at 110 mm diameter
- Includes clear safety decals and detailed multilingual instruction manual
Disadvantages
- Not suitable for pumping drinking water due to potential lubricant contamination
- Cannot handle abrasive liquids like sand, mud, or clay particles
- Requires careful installation to avoid running dry which causes immediate damage
- No built-in on/off switch necessitates external socket control for safety
- Flow rate decreases significantly if hose diameter is smaller than recommended
Product Specification
Power
1000 W
Flow Rate
1376.84 gal/h
Head Height
180.45 ft
Submersion Depth
52.49 ft
Pressure
80.01 psi
Features
without tank
Cable Length
65.62 ft
Weight
25.35 lbs
Product Description
Unlocking the Power of the Stanley SXUP1000XWE Electric Deep Well Pump
The Stanley SXUP1000XWE is a robust and reliable solution designed specifically for deep well applications where consistent water delivery is essential. Whether you are managing a private water supply, irrigating a large garden, or handling household water needs, this pump offers the performance required to get the job done efficiently. It is engineered to handle clean water extraction from wells with diameters as small as 110 mm, making it versatile for various installation environments.
At the heart of the SXUP1000XWE is a powerful 1000-watt motor that delivers a maximum flow rate of 5200 liters per hour. This high capacity ensures that even demanding tasks are completed quickly. The pump boasts an impressive maximum head of 55 meters, allowing it to lift water from significant depths without losing pressure. With a maximum immersion depth of 16 meters, it is perfectly suited for deep well installations where other pumps might struggle.
Safety is a paramount feature of this device. The unit is built with Class B motor insulation and meets IPX8 protection standards, ensuring it can operate safely while fully submerged. However, users must adhere to strict safety guidelines, such as never operating the pump dry, as this can cause irreversible damage within seconds. The pump is also designed to handle water temperatures up to 35 degrees Celsius, protecting the internal components from overheating during extended use.
Installation is straightforward but requires attention to detail. The compact design allows for easy lowering into wells using the included rope eye-ring. It is crucial to use hoses with an internal diameter of at least 25 mm to maintain optimal flow rates. The manual emphasizes the importance of bleeding the system before operation to remove trapped air, which could otherwise hinder performance. Regular maintenance, including cleaning the suction strainer and checking for wear, will extend the lifespan of the pump significantly.
This electric deep well pump is not intended for continuous commercial duty or for pumping abrasive liquids like sand or mud. It is strictly for clean water applications in residential or light gardening contexts. By following the instructions provided in the user guide, owners can ensure years of trouble-free service. The Stanley SXUP1000XWE Manual serves as an essential companion, guiding users through setup, troubleshooting, and safe operation practices to maximize the utility of this high-performance tool.
Key Features and Benefits
- High Efficiency: Delivers up to 5200 liters per hour for rapid water transfer.
- Deep Reach: Capable of lifting water from depths up to 16 meters.
- Safety First: Features IPX8 rating and Class B insulation for safe submersion.
- Compact Design: Fits easily into wells with a minimum diameter of 110 mm.
- Durable Build: Constructed to withstand rigorous household and garden demands.
Important Maintenance Notes
Always disconnect the power before any maintenance work. Never allow the pump to run dry for more than 10 seconds. Keep the suction strainer clean to prevent impeller jamming. Store the unit in a dry place if temperatures drop below 5 degrees Celsius to prevent frost damage.