Manual.ly Logo

SofarSolar 15-24KTLX-G3 Manual

0.0 · 0 Ratings

PDF manual · 74 Pages

English

M: OA-GPT-5-NAN
page

/ 74

Loading...
e86c667c1d20748cbe02d858704811312e20 page 4a
Product Name: Solar Grid-tied Inverter
ADD: 11/F., Gaoxinqi Technology Building, No.67 Area, Xingdong Community,
Xin’an Sub-district, Bao’an District, Shenzhen City,China
Tel: 0510-6690 2300
Web: www.sofarsolar.com

Chat with your SofarSolar 15-24KTLX-G3 manual using AI

Get instant AI answers from your SofarSolar 15-24KTLX-G3 manual

Ask anything about the SofarSolar 15-24KTLX-G3. Answers come from this manual, with the pages they are based on.

15-24KTLX-G3 Maintenance Schedule

Regularly
Clean and maintain the fans

Regularly clean and maintain the fans for performance and safety. Disconnect electrical connections first; clean fans with a soft brush.

Show in the manual (page 82)
Regularly
Clean and keep device labels visible

Regularly clean the device labels and keep them visible; do not cover them with objects or foreign materials.

Show in the manual (page 11)
M: gpt-5.6-terra

Ask a Question

0/1000

Do you recommend 15-24KTLX-G3?

Yes No

Frequently Asked Questions

A

The inverter supports MPPT operating voltages approximately 140–1000 V with a maximum DC input (open-circuit voltage) of 1100 V. Start-up voltage is about 160 V and full-power MPPT ranges depend on model (typically 420–850 V).

Is this answer helpful?

A

Standard communications include RS485 and USB; Bluetooth is available for app access and optional USB acquisition sticks enable Wi‑Fi or Ethernet. RS485 allows daisy-chaining up to 31 inverters; Wi‑Fi/Ethernet requires the supplied acquisition stick and router connection.

Is this answer helpful?

A

Only qualified electricians should perform installation. Disconnect AC breaker and DC switch and wait at least 5 minutes for capacitors to discharge before maintenance. PV strings must be covered or disconnected when wiring; do not ground PV positive or negative poles on this transformer-less inverter.

Is this answer helpful?

A

Firmware updates use a USB flash drive containing the provided update files. With AC breaker off and DC switch sequence followed per manual, insert the USB into the inverter, navigate to Software Update via the LCD menu, enter the password, and follow the on-screen update steps for DSP and ARM. Reboot sequence completes update.

Is this answer helpful?

A

Common faults include grid over/under voltage or frequency, GFCI triggers, low isolation, fan or overtemperature issues. First check wiring, polarity, AC and DC voltages, grounding, ventilation and event codes on the LCD. For persistent internal faults, power down and contact authorized service.

Is this answer helpful?

A

Yes. The inverters can be configured to provide reactive power support via phase shift settings and can limit active power output by percentage for grid compliance or energy management purposes.

Is this answer helpful?

A

Standard warranty is 60 months (5 years) from invoice date (or 63 months from production if invoice unavailable). Extended warranty options (e.g., additional 5, 10, or 15 years) can be purchased within specified time windows; some components like PV modules and SPD devices are excluded from extended coverage.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High peak efficiency (~98.6%) and strong European weighted efficiency for improved energy yield.
  • Dual MPPT with four string inputs provides flexibility for multi-orientation or partially shaded arrays.
  • Comprehensive protection set (anti-islanding, GFCI, over/under voltage, frequency, overcurrent, thermal derating).
  • Multiple communication options (RS485, USB, optional Wi‑Fi/Ethernet, Bluetooth) support remote monitoring and daisy-chaining.
  • IP65-rated enclosure and compact footprint (520×430×189 mm) allow outdoor installation and save space.
VS

Disadvantages

  • Transformer-less design requires strict adherence to non-grounded PV arrays, limiting some system choices.
  • Installation and maintenance must be performed by qualified electricians, raising labor requirements for owners.
  • Firmware updates and commissioning require careful country-code and grid-parameter selection to avoid misconfiguration.
  • Fan-cooled design requires periodic cleaning and potential fan replacement, increasing maintenance tasks.
  • Maximum PV Voc limit (1100 V) constrains string sizing for very large arrays or high-series-module configurations.
M: OA-GPT-5-NAN

Product Specification

Note

Prices partly include 0% VAT tax rates for AT and DE

Type

Solar inverter, without transformer, with fan

Input voltage

160-1100V DC

Input current max.

26A

MPP voltage range

420-850V DC

MPP tracker quantity

2

Output phases

3-phase

Efficiency

98.6% max., 98.2% ηEU

Input

MC4

Output

Terminals

Interfaces

Wi-Fi (WLAN), Bluetooth, 1x RJ-45, 1x RS-485

Noise level

<40dB

Protection class

IP65

Ambient temperature

-22°F to +140°F

Dimensions

20.47x16.93x7.44in (WxHxD)

M: OA-GPT-54-NAN

Product Description

SofarSolar 15K … 24KTLX-G3 Manual

The SofarSolar 15K … 24KTLX-G3 series are transformer-less, three-phase grid-tied PV inverters designed for commercial and large residential solar arrays. Covering models from 15 kW up to 24 kW, these inverters convert DC from PV strings into grid-compliant AC while offering multi-MPPT tracking, flexible communication options (RS485, USB, optional Wi‑Fi/Ethernet and Bluetooth), and robust protections for safe, reliable operation.

Key features and operation

SofarSolar 15K … 24KTLX-G3 inverters include two MPPT trackers, support up to four PV string inputs, and accept DC input voltages up to 1100 V. Typical start-up voltage is around 160 V and rated MPPT ranges target efficiency across varying irradiance. Peak conversion efficiency reaches about 98.6% with high European weighted efficiencies. Units provide adjustable active power, reactive power support, and configurable limits for grid compliance.

Installation guidance emphasizes mounting orientation (vertical or backward tilt up to 15°), ventilation clearance, correct cable sizing, grounding requirements, and qualified-electrician-only electrical work. The product supports multiple grid configurations (TN‑S, TN‑C, TT, IT) and requires coordination with local utilities before grid connection.

Controls, communications and maintenance

A clear LCD and simple button interface let installers set country codes, MPPT modes, addresses, and perform auto-tests or firmware updates via USB. Communication and monitoring are handled by RS485 daisy-chaining (up to 31 inverters) or optional Wi‑Fi/Ethernet via a USB acquisition stick for remote monitoring on the manufacturer platform.

Maintenance guidance focuses on periodic cleaning (air blower or soft brush), fan inspection/replacement, and checking heat-sink ventilation. Troubleshooting lists numerous alarm/event codes with suggested checks (grid voltage/frequency, wiring, polarity, isolation, fan and temperature issues) and directs users to contact authorized service when internal faults persist.

Safety and warranty

The manual repeatedly stresses safety: only qualified electricians should install and service the inverter, DC circuits must be isolated and allowed to discharge for 5 minutes before maintenance, and PV arrays must not be grounded to the DC poles on this transformer-less device. Standard warranty is five years (extendable to longer periods via purchase) with clear exclusions for misuse, unauthorized repairs, transport damage, and force majeure.

Notes

  • Models covered: 15KTLX-G3 to 24KTLX-G3 (including -A variants).
  • Key protections: anti-islanding, GFCI/ground-fault monitoring, over/under voltage & frequency, overcurrent, and temperature derating.
  • Physical: IP65 enclosure, fan-cooled, typical weight ~20–23 kg, footprint 520×430×189 mm.
  • Keep PV open-circuit voltage below 1100 V and follow recommended cable sizes and torque values during installation.
M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly