Horn 1 Round Maintenance Schedule
Disconnect product from power supply and let it cool down. Clean regularly using a slightly moistened, soft, fluff-free cloth.
Exchange light source before end of lifespan to avoid damage. Disconnect power and let cool before replacement.
Ask a Question
Do you recommend Horn 1 Round?
Yes NoFrequently Asked Questions
The manual specifies suitable light sources as QPAR51 and GU10 types, with a maximum power of 50W. Check the type label for the final permitted selection before inserting a bulb.
Is this answer helpful?
Yes. It is designed for operation with 230V~50Hz. Always follow the wiring instructions (L for live, N for neutral, and green-yellow for protective earth).
Is this answer helpful?
The required opening is Ø 7.5 cm. This cutout size is specifically mentioned for installation, and the luminaire is mounted using the internal retaining springs.
Is this answer helpful?
At least 0.5 m between the light source and the illuminated surface. The manual also advises extra caution near easily flammable objects such as curtains, fabrics, and similar materials.
Is this answer helpful?
No. The manual states the product must not be covered and must not have insulating material placed over it. Free air circulation is required for safe operation and cooling.
Is this answer helpful?
Switch off power first, then let the luminaire cool down. Remove the used light source and insert the new one by turning it slightly to the right. After replacement, check proper function and secure fit.
Is this answer helpful?
Do not dispose with household waste. Follow WEEE (2012/19) collection guidance and use local electrical and electronic waste return points.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Compact recessed design for a clean ceiling finish
- Uses widely available GU10/QPAR51 light sources (50W max)
- Includes clear safety rules: class I, correct L/N and earth wiring
- Simple maintenance routine: power off, cool down, then twist-and-replace the bulb
Disadvantages
- Installation must be performed by an approved electrician
- Not suitable for damp or high-humidity areas
- Must maintain at least 0.5 m from light source to illuminated surfaces
- Must not be covered; insulation can be a problem for ventilation
Product Specification
Type
Recessed light, Spot, Downlight
Old energy efficiency class for compatible bulb
A++ to E (A++ to E)
Built-in LEDs
no
Socket
1x GU10 (max. 50W)
Bulb
no
Material
Steel
Color
white
Design
round
Protection class
1
Dimensions
3.27x4.92in (DxH)
Product Description
SLV Horn 1 Round GU10 Recessed Luminaire (White Matt)
The SLV Horn 1 Round GU10 recessed luminaire in white matt brings a clean, minimalist look to ceilings while keeping the installation compact and tidy. Designed for recessed mounting, it uses a GU10 compatible light source (QPAR51 or GU10 style) and supports up to 50W maximum. The luminaire operates on 230V~50Hz and follows safety class I requirements, making it a straightforward choice for indoor lighting projects.
This luminaire is meant strictly for lighting purposes. Always keep the lighting distance in mind: the manual specifies a minimum 0.5 m distance between the light source and the illuminated surface. That requirement helps reduce the risk when the fixture is positioned near curtains, fabrics, foliage, or other easily flammable materials. Air circulation is also important, so the product must not be covered, and insulating materials should not be placed directly over it.
Installation is intended for qualified electricians only. The ceiling opening uses a cutout size of 7.5 cm diameter (Ø 7.5 cm). In the ceiling, maintain a minimum side clearance of 5 cm and ensure the recess depth is sufficient for your build-up. Electrical connection is made via L and N (live and neutral), with the green-yellow protective conductor firmly connected to the earth clamp of the luminaire. Once wired, the retaining springs are positioned to mount securely into the ceiling cutout.
With the SLV Horn 1 round GU10 recessed luminaire white matt Manual, you can also replace the light source safely. Switch off power first, let the lamp cool down, then remove the old GU10/QPAR51 light source and insert the new one with a slight turn to the right. For care and cleaning, use a lightly moistened soft lint-free cloth after the unit is de-energized.
Key results
- Recessed ceiling fitting with a Ø 7.5 cm cutout, designed to sit flush in the ceiling.
- Supports QPAR51/GU10 bulbs up to 50W max on 230V~50Hz (class I).
- Minimum 0.5 m distance from light source to illuminated surfaces to support safer use.
- Requires free air circulation, no covering with insulating or other materials.
- Bulb changes and cleaning must be done only after power is switched off and the unit cools.
Notes
- Dispose responsibly: follow WEEE (2012/19) guidance instead of household waste.
- If any visible damage, flickering, smoke, or overheating signs appear, stop use and arrange inspection by an approved electrician.
- Always verify technical details and permitted accessories on the type label before installation.