4455e4d9b59c8d18c6607a11f21da185d1a7 page 3
P
lease read these instructions carefully and keep for future use.
Thank you for purchasing the sera UV-C System 5 W. The sera UV-C System 5 W
h
as been designed for fresh and salt water aquariums up to 500 liters (132 US
g
al.).
G
eneral advice
W
ARNING: Dangerous ultraviolet radiation!
To prevent eye damage, never look directly into the UV-C lamp without pro-
t
ection when it is operating (eye damage!)
A
ttention: Glass!
There are sensitive glass parts inside the UV-C system that may easily break
w
hen shattered strongly.
A
pplication range
s
era UV-C Systems reliably remove all kinds of floating algae (cloudy, green wa-
t
er) and reduce the multiplication of thread and other algae without using
chemicals. Pathogens and cloudy water caused by bacteria are also removed.
T
he effect of the UV-C lamp is strictly physical and restricted to the water flow-
i
ng through. The inhabitants of the aquarium and the filter organisms are not
harmed by using the UV-C system.
U
V-C systems are not suitable for removing mineral cloudiness from the water.
Using fine filter materials, sera bio nitrivec and/or sera aquariaclear is recom-
mended for this purpose.
A
pplication
T
he sera UV-C System can be used in combination with a flow pump or an ex-
t
ernal filter (2). We recommend a sera aquarium pump P 1200 adjustable when
u
sing the UV-C system without a filter. If the UV-C system is to be used with an
external filter, the UV-C system is installed before the filter unit. The feed per-
formance of the filter pump should be approximately once the tank contents
per hour.
The unit cannot be operated without a pump.
Included parts (1)
sera UV-C System 5 W including lamp
Variable hose connector
∅ 15/20 mm
Required accessories
External filter, e.g. sera fil bioactive,
or pump, e.g. sera aquarium pump P 1200 adjustable
Hose with suitable internal diameter (e.g. 12 mm or 16 mm)
Parts list (3)
3.1 Union nut
3.2 Lid with viewing glass
3.3 End piece with viewing glass
3.4 Variable hose connector
∅ 15/20 mm (Water outlet) with union nut
3.5 Main tube with union nuts
3.6 Fixing stand with ballast and fixing bracket
3.7 Quartz glass cylinder with 1 O-ring seal
3.8 Variable hose connector
∅ 15/20 mm (Water intake) with union nut
3.9 End piece
3.10 UV-C lamp PL 5 W
3.11 Lamp fixture
3.12 Union nut
3.13 O-ring seal
∅ 25 mm (1 in.)
3.14 O-ring seal ∅ 79 mm (3.1 in.)
Assembly instructions
a) Operation with an aquarium pump
The sera UV-C System should be installed above the aquarium. It is advisable
to attach it horizontally on a board with the hose connectors directed up-
wards. This prevents the system running empty and overheating in case of
pump failure. The system should not be operated without water flowing
through. In case of pump failure the system must be disconnected from
power supply.
b
) Operation in connection with an external filter (2)
T
he sera UV-C System should be installed before an external filter unit. The
algae and bacteria inactivated by the UV-C light will agglomerate and are
t
hen easier to filter out. The feed performance of the filter pump should be
a
djusted in a way that the tank contents circulate approximately once per
hour.
T
he intake hose of the external filter (2.1) is cut, allowing to insert the sera
U
V-C System. Use a longer intake hose if necessary.
V
arious hose diameters can be connected to the variable hose connector (3.4).
You should saw off the smaller diameters with an (iron) saw if a hose fits on one
o
f the larger diameters. Secure the connection with a hose clamp. You should
u
se the same diameters for the intake (2.1) and the outlet (2.2).
O
peration
M
ake sure that water circulates around the lamp and that the system is free
from air bubbles before switching on the UV-C lamp. The lamp must not be op-
e
rated dry, as to prevent overheating.
T
est run
Prior to using your sera UV-C System 5 W for normal operation, the fully in-
s
talled unit must be tested under normal operation conditions for potential
leaks by running it in simple water passage mode for at least 24 hours without
turning the UV-C system on. DO NOT CONNECT THE UV-C LAMP TO THE
P
OWER/MAINS SUPPLY FOR THIS TEST. This test allows you to detect leaks.
CAUTION: The UV-C system must not be connected to the power/mains sup-
p
ly, or it must be immediately disconnected, respectively, if moisture traces
a
re detected in the UV-C lamp or in the quartz glass cylinder. Check all parts
f
or possible damage in this case (see section “Cleaning”). Consult your spe-
cialty retailer if you cannot detect or correct the problem.
Testing the UV-C lamp
Attention! Be sure to wear UV-C protection glasses.
Switch on the UV-C system for checking whether the UV-C lamp of the sera UV-
C System is working. A dim bluish light can be seen through the viewing glass
in the lid (3.2) when the lamp is on. Avoid looking into the UV-C light for a longer
time.
Cleaning
Disconnect all electrical devices from the power/mains supply by pulling their
plugs.
Dismantle the entire sera UV-C System 5 W. Loosen the screws of the fixing
bracket (3.6.1). Take the UV-C lamp out of the bracket (3.6). Loosen the large
union nut (3.12) on the side of the unit that holds the power cord. You can pull
the quartz glass cylinder (3.7) along with the lamp out of the casing on the side
that holds the power cord. Caution! The glass parts are easily broken.
Clean the quartz glass cylinder with a soft cloth. Check whether the lamp has
cracks or similar damages after you have cleaned the quartz glass cylinder. Do
not switch on the lamp for doing so. Please see the section “Maintenance/Re-
placing the lamp” in case the lamp is not intact any more.
Now clean the plastic casing on the inside. Use a long-handle brush to do so.
You can use a neutral, solvent-free cleaning agent for cleaning. Cleaning
agents are very dangerous to many aquatic organisms and must not get into
the aquarium water! All cleaned parts must be rinsed carefully before they
come into contact with aquarium water again.
Maintenance/Replacing the lamp
The UV-C lamp should be replaced after approx. one year.
Disconnect all electrical parts and units in the aquarium from the mains sup-
ply before opening the casing of the UV-C lamp!
There are sensitive glass parts inside the UV-C system that may easily break
when handled inappropriately. Pour the water out of the UV-C system.
Loosen the union nut (3.12) on the side of the unit that holds the power cord.
Take out the lamp fixture (3.11) with the lamp (3.10). It is best to pull the lamp
out of the fixture by the lamp socket. Do not let go of the lamp!
An electronic ballast with electronic starter is located in the fixing stand (3.6) of
the UV-C lamp. The ballast may only be replaced by specialized staff.
US 67 UV-C System 5 W
# GmbH • Post Box 1466 • 52518 Heinsberg • Germany
For natural aquariums

Chat with your sera UV-C-System 5W manual using AI

Get instant AI answers from your sera UV-C-System 5W manual

Ask anything about the sera UV-C-System 5W. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend UV-C-System 5W?

Yes No

Frequently Asked Questions

A

It is designed for freshwater and marine aquariums with a capacity of up to 500 liters, or about 132 US gallons.

Is this answer helpful?

A

It helps control suspended algae that create green or cloudy water and can reduce bacterial water cloudiness and pathogens in the water that passes through the chamber.

Is this answer helpful?

A

No. It is not intended to remove mineral cloudiness. Fine filter media, appropriate water changes, and suitable aquarium maintenance are recommended for mineral-based haze.

Is this answer helpful?

A

No. The clarifier requires continuous water flow from an aquarium pump or external filter. Never operate the lamp without water moving through the system.

Is this answer helpful?

A

Install it before the external filter. This arrangement can help the filter capture larger clusters formed from algae and bacteria inactivated by UV-C treatment.

Is this answer helpful?

A

Run the installed system with water circulation for at least 24 hours without connecting the UV-C lamp to power. Check for leaks or moisture before electrical operation.

Is this answer helpful?

A

Replace the 5 W UV-C lamp after approximately one year. Frequent switching on and off can reduce lamp life.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Helps clear green water caused by free-floating algae without chemical additives.
  • Suitable for freshwater and marine aquariums up to 500 liters.
  • Can be installed before an external filter to support removal of inactive particles.
  • Designed to treat only flowing water, minimizing impact on aquarium residents and filter organisms.
  • Includes a 5 W UV-C lamp and variable 15/20 mm hose connector.
VS

Disadvantages

  • Requires a pump or external filter and cannot operate as a standalone unit.
  • Does not remove mineral cloudiness, which needs fine filtration or water maintenance.
  • Requires a 24-hour water-only leak test before connecting electrical power.
  • Glass and quartz components need careful handling during cleaning and lamp changes.
  • The UV-C lamp requires replacement after approximately one year.
M: gpt-5.6-terra

Product Specification

Type

UV-C clarifier

Suitable for

Freshwater, saltwater, aquariums, terrariums

Aquarium size

max. 132.09 gal

Filtration

UV-C burner

Connections

0.47/0.63 in hose connection, 0.63/0.87 in hose connection

Power consumption

5 W

Manufacturer warranty

two years

M: gpt-5.6-terra

Product Description

sera UV-C-System 5W Water Clarifier, 500l - Read, Download & Print Free

The sera UV-C-System 5W Water Clarifier is designed to support clear, healthy-looking aquarium water in freshwater and marine tanks up to 500 liters. Using physical UV-C treatment rather than chemical additives, it targets free-floating algae that can cause green or cloudy water. It also helps reduce bacterial cloudiness and the spread of unwanted microorganisms within the water flowing through the unit.

Clearer Water Through Controlled UV-C Treatment

This compact 5 W clarifier works as part of an existing aquarium circulation setup. It requires a compatible pump or external filter to move water through the chamber, where the UV-C lamp treats suspended particles and microorganisms. When installed before an external filter, inactive algae and bacteria can form larger clusters that are easier for the filter to capture.

The unit is intended for aquarium keepers who want an additional, non-chemical approach to water clarity. Its effect is limited to water passing through the system, helping protect aquarium inhabitants and beneficial filter organisms from direct exposure. It is not a replacement for regular maintenance, filtration, water testing, or water changes.

Installation and Everyday Use

For best performance, the system should receive a steady flow rate that circulates roughly one aquarium volume per hour. It can be connected with 15 or 20 mm hose fittings, while suitable hose and clamps help create secure connections. Before electrical use, run the fully installed setup with water circulation for at least 24 hours while the UV-C lamp remains disconnected. This practical leak test helps identify installation issues early.

Never operate the clarifier without water flow. The lamp must be surrounded by water and the chamber should be free of air bubbles before switching it on. If the pump fails, disconnect the UV-C unit from power immediately to avoid overheating.

Maintenance and Safety Notes

The quartz glass cylinder should be cleaned carefully with a soft cloth, and the interior housing can be cleaned with a long-handled brush. Only neutral, solvent-free cleaners should be considered, and all parts must be thoroughly rinsed before returning to aquarium service. The UV-C lamp is recommended for replacement after about one year of use.

Note: UV-C radiation can injure eyes and skin. Use the product only when fully assembled, do not look directly at the operating lamp, keep it away from children, and use a 30 mA RCD safety switch. Mineral cloudiness requires fine filtration and appropriate aquarium care rather than UV-C treatment alone.

M: gpt-5.6-terra