SAFETY PRECAUTIONS
• All electrical units located in the water must be disconnected
from the mains/power supply before conducting work at the
aquarium.
• Check the power cable and the plug for damages before
every use.
• Please make sure the frequency and the voltage of the mains
supply equal those on the type plate before using the unit.
• Operate unit only with an inserted fault current protection
switch (RCD or FI with a trip current of 30 mA).
• Always protect the mains plug against moisture and bend the
power cable into a drip loop as to prevent water getting into
the mains socket.
• Do not lift nor carry electric devices by their mains cord.
• Pump must never be operated without water.
Technical Data
Voltage 220 – 240 V ~ 50 Hz
Water temperature up to 35 °C (95°F)
Cable length 1.8 m (6 ft.)
Spare parts
Running unit (rotor with magnetic impeller, ceramic shaft, rubber
bearings) (2.4)
Pump chamber cover with seal ring (2.5 / 2.6)
Suction holder (2.2)
Hose connector (2.3)
Warning
1. Children should be supervised to ensure that they do not play
with the appliance.
2. This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capacities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appli-
ance by a person responsible for their safety.
3. If the supply cord is damaged, the pump is not longer allowed
to be used and should be discarded.
Disposal of the unit:
Waste electrical and electronic equipment (WEEE) must not
get into domestic waste!
If ever the unit cannot be used anymore, the consumer is le-
gally obliged to hand in waste electrical and electronic equip-
ment (WEEE) separately from domestic waste, e.g. at a
collection point of his community/his district. This ensures that
waste electrical and electronic equipment (WEEE) is expertly
processed and that negative effects to the environment are
avoided.
Therefore electrical and electronic
equipment bears the following symbol:
Manufacturer warranty:
When following the directions for use, the sera lter and feed
pumps FP will perform reliably. We are liable for the freedom
from faults of our products for 2 years beginning with the pur-
chase date.
We are liable for complete awlessness at delivery. Should usual
wear and tear occur by use as intended by us, this is not consid-
ered a defect. Warranty claims are also excluded in this case. This
particularly refers to the running unit (rotor with shaft). Legal claims
are of course not reduced or limited by this warranty.
Please note the additional warranty information (*).
Recommendation:
In every case of a defect, please rst consult the specialized re-
tailer where you purchased the unit. He will be able to judge
whether it is actually a warranty case. In case of sending the unit
to us we will unnecessarily have to charge you for occurring costs.
Any liability because of contract breach is limited to intent or
gross negligence. sera will be liable in case of slight negligence
only in case of injuries to life, body and health, in case of es-
sential contractual obligations and with binding liability accord-
ing to the product liability code. In that case, the extent of
liability is limited to the replacement of contractually typically
foreseeable damages.
The pumps may only be used in fresh and marine water. War-
ranty will be void in case of operation in corrosive liquids etc.
Important warranty addendum (*):
• Impeller units that are worn, broken or stuck due to lime
deposits are a direct consequence of insufcient mainte-
nance or improper treatment. These and all subsequent dam-
ages are not covered by the warranty. Often, these damages
cannot be repaired.
• Broken rotor wings are caused by gravel or other larger,
hard particles that have been sucked into the unit. These
damages are not covered by warranty.
• Damage to the power/mains cord, will not be repaired by
the manufacturer due to safety reasons. (Reason: Moisture
that has gotten into the cable often leads to corrosion and
short-circuits in the motor later on.) Replacing the complete
cable is not possible. The pump must be discarded.
• Any damages of the cable are excluded from warranty.
7
Model Power
uptake
Qmax Hmax Hose
connector
FP 350 6 W 350 l/h
(93 gph)
0.8 m
(31.5 in.)
13 mm
1
/2”
FP 750 12 W 750 l/h
(198 gph)
1.5 m
(4.9 ft.)
13 mm
1
/2”
FP 1000 16 W 1,000 l/h
(264 gph)
1.8 m
(6.0 ft.)
15 mm
3
/5”
FP 1500 25 W 1,500 l/h
(396 gph)
2.5 m
(8.2 ft.)
20 mm
3
/4”
FP 2000 43 W 2,000 l/h
(528 gph)
3 m
(9.8 ft.)
20 mm
3
/4”
sera FP 350-2000 INT 5_2014.indd 7 20.05.2014 08:29:43

Chat with your sera FP 350 manual using AI

Get instant AI answers from your sera FP 350 manual

Ask anything about the sera FP 350. Answers come from this manual, with the pages they are based on.

FP 350 Maintenance Schedule

Before every use
Check power cable and plug for damage

Inspect the mains connection lead and the plug for any signs of damage before operating the pump.

As needed
Clean pump parts with brush and neutral detergent

Clean all parts with a brush and neutral detergent. Rinse thoroughly with tap water before reassembly to ensure no detergent enters the aquarium.

When limescale is severe
Descale running unit and motor block

If the pump is severely lime-encrusted, immerse the running unit and motor block in a descaler solution for stainless steel parts.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend FP 350?

Yes No

Frequently Asked Questions

A

Yes, models starting from the FP 350 feature a ceramic shaft which makes them safe for use in saltwater environments. This prevents corrosion issues common with standard metal parts.

Is this answer helpful?

A

You can adjust the flow by turning the rotary adjusting cap located on the intake grid. Rotating it in the plus direction increases the flow to maximum, while the minus direction reduces the flow.

Is this answer helpful?

A

Yes, the compact shape of the pump allows it to be placed inside internal filters or directly in the aquarium, provided it remains fully submerged for cooling.

Is this answer helpful?

A

The manufacturer provides a two-year warranty covering freedom from defects from the date of purchase. It excludes damage from improper maintenance or running the pump dry.

Is this answer helpful?

A

No, the motor block is encapsulated for electrical isolation and cannot be repaired. If the motor block fails, the unit must be replaced.

Is this answer helpful?

A

The motor block is cooled by water and the ceramic shaft is lubricated by water. Running it dry will cause overheating and damage to the mechanical components.

Is this answer helpful?

A

Clean parts with a brush and neutral detergent. Ensure no cleaner enters the aquarium and rinse thoroughly. Descale components only if necessary using appropriate solutions.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Highly adjustable flow rate using rotary cap
  • Compact design suitable for nano and large tanks
  • Low energy consumption for cost efficiency
  • Ceramic shaft supports safe saltwater operation
  • Compatible with internal filter installations
VS

Disadvantages

  • Motor block cannot be repaired if damaged
  • Warranty void if cable is damaged
  • Pump must not operate without water
  • Ceramic shaft requires regular maintenance
  • Cable damage requires full unit replacement
M: QW-35-FL

Product Specification

Type

Submersible Pump

Suitability

Freshwater, Seawater, Aquarium

Flow Rate

92.46 gal/h (adjustable)

Max Head

31.50 in

Connections

0.51 in Pressure Side (Hose Connection (Inner Diameter))

Power Consumption

6W

Features

70.87 in Power Cord, Suction Cups

Manufacturer Warranty

2 years

M: QW-35-FL

Product Description

Manual Overview: sera FP 350 Adjustable Filter and Transfer Pump

The sera FP 350 Adjustable Filter and Transfer Pump represents a significant advancement in aquarium technology designed for both novice and experienced hobbyists. This comprehensive range of pumps offers exceptional versatility, catering to a wide variety of aquatic tank sizes ranging from compact nano setups to large marine aquariums. The primary advantage lies in its adjustable functionality. Users can easily manage the water flow rate using the rotary adjusting cap located on the intake grid. This feature ensures that the pump delivers exactly the right amount of circulation required to maintain a stable biological system within the tank.

Compact and Energy Efficient Design

Constructed with a focus on durability and space efficiency, the sera FP pumps boast a sleek profile that allows them to remain virtually unobtrusive when installed inside an aquarium or within internal filter units. One of the key highlights of this equipment is its low energy consumption. Despite delivering high water agitation performance, the motor is designed to operate economically. For models starting at the FP 350, a ceramic shaft is utilized. This technical detail is crucial because it enables the pump to operate safely in saltwater environments without suffering from corrosion. The motor block remains cool due to direct contact with the water, eliminating the need for air cooling mechanisms.

Installation and Maintenance

Proper installation involves placing the pump fully submerged on the aquarium floor or against the glass wall. Four suction cups on the holder plate secure the unit to prevent unwanted movement. It is vital to remember that the pump operates continuously and must never run dry, as the cooling and lubrication rely entirely on water immersion. Cleaning is straightforward using a brush and neutral detergent. However, care must be taken to ensure no cleaning agents enter the tank. If the running unit becomes worn or clogged with debris, it can be replaced easily, though the motor block itself requires professional handling as it is encapsulated for electrical safety. Regular cleaning preserves the efficiency of the rubber bearings and seal rings.

Safety and Warranty

Safety remains a paramount consideration for all electrical devices in water. An RCD or FI switch is recommended to protect against electrical faults. A two-year warranty covers defects. Warranty excludes improper maintenance, dry running, or corrosive liquids. Users are advised to consult the specialized retailer for any claims regarding defects. This assurance protects your investment against early component failure. Note: Always disconnect power before maintenance.

M: QW-35-FL

© Copyright 2026 Manual.ly