Please read these instructions carefully and keep for
future use.
The sera air plus air pumps are especially energy saving
and powerful air pumps.
They are suitable for oxygen enrichment by means of an
airstone, for operating air-driven filters (e.g. sera inter-
nal filters L), or air-driven moveable decoration.
Assembly and safety advice:
• The air pump must be placed above the water surface
(dry and protected against splash water!), but not on
top or directly above the aquarium (fig. 1).
• We urgently recommend using the supplied sera non-
return valve/s with each hose connection as to pre-
vent danger of water flowing back (fig. 2). This also
considerably increases the life span of the mem-
branes and rubber shaft inserts.
Never leave the sera air pumps switched on for a
longer period without sufficient counter pressure (on
one or several outlets) or at temperatures below 5°C
(41°F). Otherwise the rubber parts may be subject to
wear and tear within shortest time, especially in case
of high pump performance (adjustable versions).
• Every air pump may eventually “wander” due to its
own vibration. Avoid this by placing it on a rough, en-
tirely flat plane. We recommend to secure it with
some wire or string that you may attach to the eye
on the back side of the casing’s bottom (fig. 3).
• Pull all mains plugs before you touch the aquarium
water!
• Do not place within the reach of children!
• Suitable only for operation outside the water!
• Suitable only for pumping air.
•
The sera air pump must only be used in closed, dry rooms.
• The sera air plus must always be placed inside the
house, in a safe and dry place, also if you use it for
oxygen enrichment of garden ponds (fig. 4).
• Protect against frost!
• Too high air humidity may cause corrosion of metal
parts. This and all follow-up damage is not covered by
warranty.
• Avoid direct sun irradiation and other heat sources.
• Do not touch pump or plug with wet hands, and avoid
splash water!
• Ensure that the electrical plug of the switched-on unit
is freely accessible at all times.
• If aquarium water has flown back into/up to the air
pump, immediately pull the mains plug and consult
your specialized retailer.
• The sera air pump must be used only for the stated
purpose.
• Attention! By all means pull mains plug before open-
ing the air pump!
• Damages of electric or electronic motor parts, the
cord or plug and the casing must only be repaired by
the manufacturer or by authorized repair workshops.
The air pump must be immediately disconnected
from the mains supply and must not be operated any
more before the damage is entirely repaired. This also
applies for deliberate alteration of these parts.
What to do if performance of the sera air plus decreases?
If performance of the sera air plus decreases, check
whether the connected filter or airstone is clogged and
whether the air hose has a kink or is clogged. Check the
air filter of the air pump (located at the bottom of the
pump – with the sera air 110 plus, fig. 5 –, or in the small
filter drawer – with the sera air 275 R plus and the sera
air 550 R plus, fig. 6) if this is not the case. If this does
not reveal considerable pollution, it is likely that the
membranes are worn out. When heavily polluted we
recommend to replace the air filter.
Depending on surrounding temperature and load, the
mem branes must be replaced after 6 – 12 months, with
every air pump. Membrane kits are available as spare
parts.
Please consult your specialized retailer in this case.
The membrane sets of the sera air 275 R plus and 550 R
plus are identical. The sera air 550 R plus merely con-
tains a second set.
If only a single set is to be replaced in the sera air 550 R
plus, you may install item No. 06732 (for sera air 275 R
US
Information for use
Air pump sera air 110 plus for aquariums,
electronically adjustable air pumps sera air 275 R plus and sera air 550 R plus
for aquariums and garden ponds
Garantie:
Bei Beachtung der Gebrauchsinformation arbeitet die
sera air plus Luftpumpe zuverlässig. Wir haften für die
Fehlerfreiheit unserer Produkte ausschließlich im Rah -
men der gesetzlichen Bestimmungen ab dem Kauf da tum.
Wir haften für vollständige Mängelfreiheit bei Übergabe.
Sollten durch bestimmungsgemäßen Gebrauch übliche
Abnutzungs- oder Verbrauchserscheinungen auftreten,
stellt dies keinen Mangel dar. In diesem Fall sind auch
die Gewährleistungsansprüche ausgeschlossen. Dies be-
zieht sich insbesondere auf die Membranen und die
Rückschlagventile.
Wir empfehlen Ihnen für jeden Fall eines Mangels, sich
zunächst an den Fachhändler zu wenden, bei dem Sie
das Gerät erworben haben. Er kann beurteilen, ob tat-
sächlich ein Garantiefall vorliegt. Bei einer Zusendung an
uns müssen wir Ihnen etwaige unnötigerweise anfallen-
de Kosten belasten.
Jegliche Haftung wegen Vertragsverletzung ist auf
Vorsatz und grobe Fahrlässigkeit beschränkt. Nur für
die Verletzung von Leben, Körper und Gesundheit, bei
Verletzung wesentlicher Vertragspflichten und bei einer
zwingenden Haftung nach dem Produkthaftungsgesetz
haftet sera auch bei leichter Fahrlässigkeit. In diesem
Fall ist die Haftung dem Umfang nach auf den Ersatz der
vertragstypisch vorhersehbaren Schäden begrenzt.
sera air Membranp_GBI INT:GBI seramic 16.07.09 09:38 Seite 6

Chat with your sera air plus manual using AI

Get instant AI answers from your sera air plus manual

Ask anything about the sera air plus. Answers come from this manual, with the pages they are based on.

air plus Maintenance Schedule

Remind me when maintenance is due
Every 6-12 months
Replace the pump membranes

Membranes must be replaced every 6 to 12 months depending on ambient temperature and load. Always unplug the device before opening the casing.

As needed
Inspect and replace air filter if dirty

Check the air filter for pollution if performance decreases. Replace the filter if it is heavily polluted or clogged.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend air plus?

Yes No

Frequently Asked Questions

A

Membranes should be replaced every 6 to 12 months depending on the ambient temperature and the load placed on the pump. Regular replacement ensures consistent performance and prevents damage to other components.

Is this answer helpful?

A

Yes, the sera air plus pumps are suitable for garden ponds. However, they must always be installed inside a house or a safe, dry location, never directly in the water or exposed to frost.

Is this answer helpful?

A

Loud noises often result from resonance vibrations caused by an unsuitable location or lack of counter-pressure. Placing the pump on a flat, rough surface and using a hose clamp or non-return valve can significantly reduce the noise level.

Is this answer helpful?

A

If aquarium water flows back into the pump, immediately unplug the device. Do not attempt to use it until it has been inspected by a specialist retailer to prevent electrical hazards and further damage.

Is this answer helpful?

A

The kits include necessary non-return valves and Y-connectors for multi-outlet models. You may need to purchase additional hose clamps or regulators if you want to manually adjust airflow to reduce noise.

Is this answer helpful?

A

No, damages to electric or electronic motor parts must only be repaired by the manufacturer or authorized workshops. Attempting self-repair voids the warranty and poses safety risks.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Energy-efficient operation reduces electricity costs over time.
  • Thick sound-absorbing casing minimizes operational noise levels.
  • Electronic regulation on R plus models offers precise airflow control.
  • Durable design supports deep water pumping up to 1.2 meters.
  • Easy membrane replacement extends product lifespan significantly.
VS

Disadvantages

  • Cannot regulate flow below 1 liter per hour due to technical limits.
  • Longer hoses and accessories may reduce effective pumping depth.
  • Membranes require replacement every 6 to 12 months with heavy use.
  • Unit must be secured against vibration to prevent movement.
  • Noise may still be audible in very quiet sleeping areas at night.
M: QW-35-FL

Product Specification

Range

Oxygen supply

Type

Air pump

M: QW-35-FL

Product Description

Elevate Your Aquatic Environment with sera air plus

Creating a thriving ecosystem in your aquarium or garden pond requires consistent oxygenation, and the sera air plus Aquarium Air Pumps Manual highlights why these devices are essential for hobbyists. These pumps are engineered to be both energy-efficient and powerful, making them ideal for oxygen enrichment using airstones, powering air-driven filters like the sera internal filter L, or animating decorative elements that move with airflow.

The series includes three distinct models: the sera air 110 plus, the electronically adjustable sera air 275 R plus, and the high-performance sera air 550 R plus. Each model is designed to operate safely above the water surface in dry, splash-proof environments, ensuring longevity and safety. The manuals emphasize the importance of placing the unit on a rough, horizontal surface to prevent vibration-induced movement, and recommend securing it with wire or string attached to the rear eyelet.

A critical feature of the sera air plus line is its ability to handle significant back pressure. The created pressure allows the pump to push air through water columns of approximately 1.2 meters when the hose end is free. However, users must be aware that long hoses exceeding 3 meters, non-return valves, and air stones can reduce this performance. To mitigate noise, which can occur even in quiet rooms at night, the pumps feature thick, sound-absorbing casings. Adding a hose clamp or regulator valve creates necessary counter-pressure, significantly lowering the hum and extending the life of the membranes.

Maintenance is straightforward yet vital. Membranes should be replaced every 6 to 12 months depending on usage and temperature. The manuals provide clear instructions for swapping these parts, noting that a specific black plate must be transferred from the old membrane to the new one to ensure functionality. For the multi-outlet models, Y-connectors allow for increased pumping depth by combining outputs. Always remember to disconnect the power before opening the unit for maintenance to avoid electrical hazards.

Important Notes

  • Never submerge the pump in water; it must remain dry.
  • Use non-return valves on all hose connections to prevent water backflow.
  • Replace air filters if heavily clogged to maintain optimal flow.
  • Dispose of old units according to local electronic waste regulations.