2bcecf9b32af0d9f93cec3c14c994d594fa3 page 1
DANGER / 危险
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Disconnect all power before servicing equipment.
Failure to follow these instructions will result in death or serious injury.
电击、爆炸或弧闪的危险
在此电力设备 上进行工作时, 请先切断所有电源。
不遵循上述规定将可能导致人员伤亡。
WARNING /
警告
LC1D
pp
RISK OF FIRE OR ELECTRIC SHOCK (FOR CONTACTOR WITH UL HI-FAULT SHORT CIRCUIT CURRENT RATINGS ONLY)
The opening of the branch-circuit protective device may be an indication that a fault current has been interrupted.
To reduce the risk of fire or electric shock, current-carrying parts and the other components of the controller
should be examined and replaced if damaged.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
可能有火灾或者触电的危险(仅限UL高故障短路电流额定值的接触器)
支路保护设备断开,表明故障电流已被中断。
为降低火灾或触电风险,应检查带电部件和 其他控制元件,如有损坏,需及时更换。
不遵循上述说明可能导致人员伤亡或设备损坏。
"For motor starting use Schneider Electric TeSys Protect - Deca overload relays."
电动机起动请使用施耐德电气TeSys保护Deca系列热过载继电器。
3P AC TeSys Deca contactors are grade 3 (LC1D09
-
> LC1D18) and grade 2 (LC1D25
-
> LC1D38)according to GB 21518.
Maximum power consumption lower than 9.5 VA.
根据GB 21518标准,三极TeSys Deca 系列交流接触器能效等级为
3
级
(LC1D09
-
> LC1D18)
和
2
级
(LC1D25
-
> LC1D38),
产品最大吸持 功率低于
9.5 VA
LAD4TpDL
LAD4DDL
LAD9DL
1
2
c
LAD4RC
LAD4V
LAD4T
LAD4BB
a
a
a, c, LC, AC/DC
LADN
a, c, AC/DC
LADN
a, c, AC/DC
LADT /
LADR
A1+
A2-
LAD8N a LAD8N AC/DC
A1
A2
13/NO
14
1/L1
2/T1
3/L2
5/L3
22
21/NC
4/T2
6/T3
LC1D09 − D150 LC1D098 − D258 LC1DT20 − DT80A
13/NO
14
1/L1
2/T1
3/L2
5/L3
22
21/NC
4/T2
6/T3
7/L3
8/T4
A1
A2
A1
A2
13/NO
14
1
2
R1
R3
22
21/NC
R2
R4
3
4
3
2
LAD6K / LADN
LAD / LADR
1
1
2
Click!
Click!
Click!
1
2
1
2
use of this product in EMC environment B may require mitigation measures to avoid unwanted disturbance.
full open AC at 10%Us.
在EMC环境B中使用 此产品可能需要采取缓解 措施以避免不 必要的干扰。
交流情况需在10%下完全释放。
AC/DC
www.se.com
1/2W9 1378304 0211 A14
05-2022
1/2

Chat with your Schneider Electric TeSys D LC1D manual using AI

Get instant AI answers from your Schneider Electric TeSys D LC1D manual

Ask anything about the Schneider Electric TeSys D LC1D. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend TeSys D LC1D?

Yes No

Frequently Asked Questions

A

The maximum power consumption remains lower than 9.5 VA to ensure noticeable energy savings during daily continuous operation cycles throughout the year for efficient performance.

Is this answer helpful?

A

Current-carrying parts should be examined regularly during scheduled maintenance activities to detect damage from excessive fault currents and reduce fire risks immediately.

Is this answer helpful?

A

Yes, compliance with UL and CSA marks adds confidence for North American commercial installations requiring specific certification types for general public safety and legal use.

Is this answer helpful?

A

Pairing with TeSys Protect Deca overload relays optimizes motor starting performance further for long-term operational success and stability during heavy industrial cycles.

Is this answer helpful?

A

Terminal capacities support wire sizes from small gauges up to 16 mm2 total cross section area measurements depending on the specific model number selected.

Is this answer helpful?

A

Yes, they are highly suitable for elevator duties, offering specific horsepower ratings across various single and three-phase voltage configurations available for purchase.

Is this answer helpful?

A

In electromagnetic compatible environments, mitigation measures might be necessary to prevent signal interference issues affecting nearby sensitive electronics during normal operation.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High safety standards minimize risk of shock or explosion during operation.
  • Low power consumption under 9.5 VA ensures energy efficiency savings.
  • Meets Grade 2 and 3 efficiency ratings per international GB standards.
  • Supports diverse applications including elevators and refrigeration compressors.
  • Compatible with TeSys Protect Deca relays for optimized motor starting.
VS

Disadvantages

  • Requires power disconnection before servicing to ensure operator safety.
  • May need EMC mitigation measures in certain compatible environments.
  • Terminal wiring sizes vary by model number causing selection complexity.
  • Specific torque settings required for secure connections at terminals.
  • Limited to specific voltage configurations for certain certifications.
M: QW-35-FL

Product Specification

Type

Other

M: QW-35-FL

Product Description

Discovering Reliability with the Schneider Electric LC1D Series

When managing industrial motor applications, safety and performance are paramount priorities for professional engineers today. The Schneider Electric LC1D 3p, +1NC+1NO, 5.5 kW, 12 A, 400 V AC3, Coil 230 V AC Contactor stands out as a robust solution for demanding electrical environments around the globe. This component ensures efficient control of three-phase motors while maintaining the highest safety standards required by modern manufacturing facilities globally.

Safety First Approach Always

Electrical systems carry inherent risks that demand constant respect from all operators. Proper handling is crucial to prevent dangerous accidents during routine operation or essential repair work. Users must disconnect all main power sources before servicing equipment to avoid hazards like electric shock or arc flash. Failure to follow strict safety protocols can lead to serious injury or potentially death for personnel. Additionally, current-carrying parts should be examined regularly during scheduled checks. If damage is detected due to excessive fault currents, immediate replacement reduces fire risks within the control panel housing.

Performance and Efficiency Metrics

TeSys Deca contactors offer excellent efficiency ratings according to established international standards regulations and testing protocols. Maximum power consumption remains lower than 9.5 VA, ensuring energy savings during daily continuous operation throughout the operating year. These devices meet Grade 2 and Grade 3 classifications depending on the specific model size by dedicated design teams. This versatility allows engineers to select the precise right unit for their load requirements without compromising on overall quality or reliability factors during production.

Versatile Industrial Applications

Beyond standard motor starting tasks, these contactors support diverse operational functions in many industrial sectors globally. They are suitable for elevator duties, offering specific horsepower ratings across various single and three-phase voltage configurations available for purchase. Hermetic refrigeration compressors also benefit from their consistent reliability under varying thermal and electrical loads. Lighting circuits using magnetic ballasts find full compatibility within defined amperage limits globally recognized standards. Compliance with UL and CSA marks adds significant confidence for North American commercial installations requiring certification for general public safety.

Installation and Maintenance Tips

Successful integration requires careful attention to wiring details provided by authorized manufacturer guidelines locally. Terminal capacities vary between model numbers, supporting wire sizes up to 16 mm2 total cross section area measurements. Torque specifications range from 1.7 to 2.5 Newton meters for secure mechanical connections at specific terminal points. In electromagnetic compatible environments, mitigation measures might be necessary to prevent signal interference issues. Always ensure full open AC voltage levels match system requirements before physical installation begins in the field. Choosing the right contactor simplifies future maintenance tasks and enhances overall system longevity effectively over extended periods of reliable service use. Pairing with TeSys Protect Deca overload relays optimizes motor starting performance further for long-term operational success. This selection ensures stable electrical operations consistently.

M: QW-35-FL

© Copyright 2026 Manual.ly