05/2021 1/8
GDE60782-00
Acti9 - iC40N ARC - A9TPp46pp
en
Arc fault detection circuit breaker.
fr
Disjoncteur détecteur d’arc.
es
Interruptor automático con detector de arco eléctrico.
it
Interruttore magnetotermico con protezione da arco.
de
Fehlerlichtbogen-Schutzeinrichtung mit LS-Schutz.
PLEASE NOTE
b The installation, maintenance and eventual replacement of this device must only be
carried out by a qualied electrician.
b This device must not be repaired.
b All applicable local, regional and national regulations must be complied with during
the installation, use, maintenance and replacement of this device.
b This device should not be installed if, when unpacking it, you observe that it is
damaged.
b Schneider Electric cannot be held responsible in the event of non-compliance with the
instructions in this document and in the documents to which it refers.
b The service instruction must be observed throughout the life time of this device.
REMARQUE IMPORTANTE
b L’installation, l’entretien et le remplacement éventuel de cet appareil doivent être
e󰀨ectués uniquement par un personnel qualié.
b Cet appareil ne doit pas être réparé.
b Toutes les réglementations locales, régionales et nationales applicables doivent être
respectées lors de l’installation, l’utilisation, l’entretien et le remplacement de cet
appareil.
b Cet appareil ne doit pas être installé si, lors du déballage, vous observez qu’il est
endommagé.
b Schneider Electric ne peut être tenu responsable en cas de non-respect des
instructions contenues dans ce document et dans les documents auxquels il se réfère.
b Les instructions de service doivent être respectées tout au long de la durée de vie de
cet appareil.
TENGA EN CUENTA
b La instalación, el mantenimiento y el eventual reemplazo del equipo eléctrico solo se
debe realizar por personal cualicado.
b El equipo no debe repararse.
b Durante la instalación y el uso de este dispositivo, se deben cumplir todas las
normativas locales, regionales y nacionales aplicables.
b Este dispositivo no debe instalarse si, al desembalarlo, se observa que está dañado.
b Schneider Electric no se hace responsable en caso de incumplimiento de las
instrucciones de este documento y de los documentos a los que se reere.
b Las instrucciones de uso se deben respetar durante toda la vida útil del producto.
NOTA
b Le operazioni di installazione, utilizzo, riparazione e manutenzione del presente
dispositivo elettrico devono essere eseguite esclusivamente da personale qualicato.
b Il dispositivo non deve essere riparato.
b Durante l’installazione e l’uso del presente dispositivo, è obbligatorio rispettare tutte le
normative locali, regionali e nazionali applicabili.
b Non installare il dispositivo se durante le operazioni di disimballaggio si nota che è
danneggiato.
b Schneider Electric non si assume alcuna responsabilità in caso di mancata
osservanza delle istruzioni riportate nel presente documento e nei documenti a cui viene
fatto riferimento.
b necessario rispettare le istruzioni di servizio per tutta la durata di vita del prodotto.
BITTE BEACHTEN
b Das elektrische Gerät darf ausschließlich von einem qualizierten Elektriker installiert,
verwendet, repariert und gewartet werden.
b Dieses Gerät darf nicht repariert werden.
b Bei der Installation und Verwendung dieses Geräts müssen sämtliche lokalen,
regionalen und nationalen Vorschriften eingehalten werden.
b Dieses Gerät darf nicht installiert werden, wenn Sie beim Auspacken
Beschädigungen feststellen.
b Schneider Electric kann keinesfalls für die Nichtbeachtung der Anweisungen in dieser
Anleitung oder Anweisungen in Dokumenten, auf die sie Bezug nimmt, haftbar gemacht
werden.
b Während der gesamten Produktlebensdauer müssen die Wartungsanweisungen
befolgt werden.
fr es it deen

Chat with your Schneider Electric Acti9 iC40N ARC manual using AI

Get instant AI answers from your Schneider Electric Acti9 iC40N ARC manual

Ask anything about the Schneider Electric Acti9 iC40N ARC. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend Acti9 iC40N ARC?

Yes No

Frequently Asked Questions

A

It protects against arc faults (parallel and series), overloads and short circuits by combining AFDD functionality with LS overcurrent protection, tripping quickly to reduce fire and electrical hazards.

Is this answer helpful?

A

This model is a 1p+N breaker rated 10 A with a C-characteristic tripping curve and a short-circuit breaking capacity of 6000 A, suitable for many residential and light commercial circuits.

Is this answer helpful?

A

Use the built-in Test (T) button to run self-diagnostics after installation and at regular intervals. VISI-TRIP LEDs display patterns for parallel arc, series arc, overvoltage or internal faults; a recall function helps review the trip cause.

Is this answer helpful?

A

No. The device is not repairable. If it is defective or damaged, it must be replaced. Installation, maintenance and replacement should be performed only by a qualified electrician.

Is this answer helpful?

A

Always de-energize power before wiring, use a voltage tester to confirm conductors are dead, follow local regulations, and disconnect all input/output wires before dielectric testing. Ensure proper DIN-rail mounting and terminal wiring.

Is this answer helpful?

A

Run the self-test after installation and periodically using the Test button, monitor VISI-TRIP LED indications, keep records via the unique product identifier and QR code, inspect for damage, and follow manufacturer service instructions.

Is this answer helpful?

A

Follow local e-waste regulations. The product complies with WEEE directive guidance, so dispose of or recycle it according to applicable electronic waste procedures.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Arc-fault detection plus LS protection in a single compact device
  • VISI-TRIP LEDs and Test button simplify commissioning and troubleshooting
  • 6000 A breaking capacity with C-characteristic provides robust short-circuit protection
  • DIN-rail clip and clear terminals enable fast installation
  • QR code and unique ID streamline maintenance and tracking
VS

Disadvantages

  • Must be installed and maintained by a qualified electrician
  • Device is non-repairable — replacement required if faulty
  • Requires learning LED diagnostic patterns for accurate fault interpretation
  • Higher cost than standard MCBs without AFDD capability
  • Dielectric testing mandates full disconnection of all conductors
M: OA-GPT-5-NAN

Product Specification

Type

AC

Number of poles

1 + N

Rated voltage

230V

Rated current

10A

Tripping characteristic

C

Rated breaking capacity

6kA

Width

1.42 in

Module units

2

Special features

Neutral conductor on left

M: OA-GPT-54-NAN

Product Description

Schneider Electric Acti9 iC40N ARC — AFDD + LS Switch (1p+N, 10A, C-characteristic, 6000A)

The Schneider Electric Acti9 iC40N ARC combines arc-fault detection (AFDD) with residual overcurrent protection (LS breaker) in a compact 1p+N module. Rated 10 A with C-characteristic tripping and 6000 A short-circuit breaking capacity, this device protects circuits from parallel and series arcing, overloads and short circuits while offering diagnostic features and simple DIN-rail mounting.

Engineered for residential and light commercial installations, the Acti9 iC40N ARC monitors the load for signature arc events and intervenes rapidly to reduce fire risk. It integrates visual trip diagnosis (LED VISI-TRIP) and a multifunction Test/Reset button for regular self-checks. The unit supports top or bottom feeding, has clear positive contact indication (VISI-SAFE) and provides a QR code and unique product identifier to simplify commissioning and maintenance.

Practical for installers, the breaker has standardized terminals and a DIN-rail clip for quick mounting. The design includes clear safety warnings and diagnostic procedures: always isolate power before testing or maintenance, run self-diagnostics after installation and periodically thereafter, and follow qualified electrician requirements. The product features guidance for dielectric tests and steps to identify tripping causes (parallel arc, series arc, overvoltage, internal fault) via LED patterns and recall functions.

Beyond protection, the Acti9 iC40N ARC helps streamline serviceability. Diagnostic LEDs and a recall function let technicians identify trip causes without invasive inspection. The QR code links to commissioning and maintenance resources, while the unique product identifier aids tracking across installations. Built to Schneider Electric standards, it complies with WEEE disposal guidance and carries manufacturer service instructions.

Notes:

  • Only qualified electricians should install, maintain or replace the device. Do not attempt repairs.
  • Always de-energize circuits before wiring, dielectric testing, or diagnostic procedures.
  • Run the built-in self-test after installation and periodically by pressing the Test button.
  • If the unit is damaged on unpacking, do not install it and contact the supplier.

Pros and cons (summary):

  • Pros:
    • Arc-fault detection plus LS protection in a single compact device
    • VISI-TRIP LED diagnosis and Test button for easy commissioning and maintenance
    • 6000 A breaking capacity with C-characteristic provides robust short-circuit protection
    • DIN-rail mounting and clear terminals speed installation
    • QR code and unique identifier simplify tracking and service
  • Cons:
    • Requires qualified electrician for installation and maintenance
    • Not repairable — full replacement needed if faulty
    • May require familiarization with LED diagnostic codes for proper fault interpretation
    • Adds cost vs. a basic MCB without AFDD functionality
    • Dielectric testing requires full disconnection of all conductors

Most important results (3-5):

  • Arc and fault detection: Identifies parallel and series arc events and trips to reduce fire risk.
  • Combined protection: Integrates AFDD and LS (overcurrent) protection in a single 1p+N module.
  • Diagnostics & service: VISI-TRIP LEDs, Test/Reset button, QR code and unique ID simplify troubleshooting.
  • Electrical ratings: 10 A, C-characteristic trip curve, 6000 A breaking capacity suitable for many installations.
  • Safety compliance: Requires installation by qualified electricians and adherence to dielectric and safety procedures.

FAQ:

  • Q: What does Acti9 iC40N ARC protect against? A: It protects against arc faults (parallel and series), overloads and short circuits by combining AFDD functionality with LS overcurrent protection, tripping quickly to reduce fire and electrical hazards.

  • Q: What are the electrical ratings of this device? A: This model is a 1p+N breaker rated 10 A with a C-characteristic tripping curve and a short-circuit breaking capacity of 6000 A.

  • Q: How do I test and diagnose the breaker? A: Use the built-in Test (T) button to run self-diagnostics after installation and periodically. VISI-TRIP LEDs indicate trip cause patterns (parallel arc, series arc, overvoltage, internal fault) and a recall function can re-display the cause.

  • Q: Can I repair the Acti9 iC40N ARC if it fails? A: No. The device must not be repaired. If defective or damaged, it should be replaced and only handled by a qualified electrician.

  • Q: Are there special installation requirements? A: Yes. Installers must follow local regulations, de-energize circuits before wiring or dielectric testing, ensure terminals and feeding orientation (top/bottom) are correct, and secure DIN-rail mounting.

  • Q: What maintenance is recommended? A: Run regular self-tests via the Test button, inspect for physical damage, follow diagnostic LED guidance when a trip occurs, and record the unique product identifier for maintenance tracking.

  • Q: Is disposal considered by the manufacturer? A: The product follows WEEE directive guidance for end-of-life disposal; follow local e-waste regulations when replacing the device.