Schneider Electric Acti9 iC40N ARC Active Manual
PDF manual · 10 Pages
English

Quick check
Incorrect answer, please try again.
Chat with your Schneider Electric Acti9 iC40N ARC Active manual using AI
Get instant AI answers from your Schneider Electric Acti9 iC40N ARC Active manual
Ask anything about the Schneider Electric Acti9 iC40N ARC Active. Answers come from this manual, with the pages they are based on.
Ask a Question
Do you recommend Acti9 iC40N ARC Active?
Yes NoFrequently Asked Questions
The primary function is to combine arc fault detection (AFDD) with overload and short-circuit protection (LS) in a single 1P+N device rated 16 A, reducing fire risk from electrical arcs while protecting circuits from overloads and short-circuits.
Is this answer helpful?
A multi-function LED displays communication and fault diagnostics with color-coded statuses: identification and normal operation (green/orange), communication loss or failure (red), and specific trip causes such as parallel/series arc, overvoltage, or internal faults (blue codes and patterns).
Is this answer helpful?
No. Installation, maintenance, and replacement must be carried out only by a qualified electrician. The device must not be repaired; follow local regulations and Schneider Electric instructions. Replace any unit damaged during unpacking.
Is this answer helpful?
Run a self-diagnostic test after installation and at regular intervals by pressing the Test button. Before dielectric or insulation resistance testing, disconnect all input and output conductors. Follow service instructions for the device’s lifetime.
Is this answer helpful?
Yes. The product includes communication capabilities and a QR code for commissioning. It can pair with a concentrator and integrate with EcoStruxure Power Commission for system-level monitoring and diagnostics; consult the concentrator manual for configuration.
Is this answer helpful?
The unit is 1P+N, rated 16 A with a B-characteristic trip curve and a breaking capacity of 6000 A. It is intended for single-phase circuits; it is not suitable for three-phase or higher-current applications without appropriate product variants.
Is this answer helpful?
After ensuring safety by switching power off and verifying circuits are de-energized, use the VISI-TRIP diagnostic indicators and the Test/reset functions to identify the trip cause (arc, overload, short-circuit, overvoltage, or internal fault). Follow prescribed diagnostic steps or contact a qualified electrician.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Combines AFDD and LS protection for arc, overload, and short-circuit detection in one compact 1P+N device.
- Integrated communication and QR-assisted commissioning simplify monitoring and system integration with EcoStruxure.
- VISI-TRIP diagnostics and multi-function LED provide clear trip cause identification and communication status.
- High safety profile reduces fire risk from arc faults and supports preventive maintenance via self-tests.
- DIN-rail mounting and clear terminals enable straightforward installation in distribution boards.
Disadvantages
- Requires qualified electrician for installation and maintenance; not user-serviceable or repairable.
- Communication depends on a concentrator for full system functionality, adding complexity and cost.
- Limited to 16 A and 1P+N applications; not suitable for three-phase or higher-current circuits.
- Dielectric tests and wiring require full isolation of conductors, increasing service time and precautions.
- If damaged on delivery or mishandled, the unit must be replaced, creating potential supply chain downtime.
Product Specification
Type
AC
Number of poles
1 + N
Rated voltage
230V
Rated current
16A
Tripping characteristic
B
Rated short-circuit capacity
6kA
Width
1.42in
Modular units
2
Special features
Neutral conductor left
Product Description
Schneider Electric Acti9 iC40N ARC Active — AFDD + LS switch + comm., 1P+N, 16A, B-char., 6000A Manual
The Schneider Electric Acti9 iC40N ARC Active combines arc fault detection (AFDD) with a compact residual overcurrent and short-circuit protective switch (LS) and integrated communication. Designed for single-phase plus neutral circuits, this 1P+N device rated 16 A with B-characteristic and 6000 A breaking capacity delivers layered protection for modern residential and light commercial installations, reducing fire risk from arcing while maintaining overload and short-circuit safety.
Key product highlights
Built for safety and connectivity, the Acti9 iC40N ARC Active features an automatic VISI-TRIP diagnostic system that distinguishes arc, overvoltage, short-circuit, overload, and internal faults. A multi-function LED provides clear status and communication feedback (identification, normal communication, loss of communication, and fault conditions). The unit integrates DIN-rail mounting, clear power terminals, a QR code for commissioning and maintenance, and a test/reset button to run periodic self-diagnostics.
Why it matters
Arc faults are a major cause of electrical fires. By combining AFDD technology with traditional protection (LS), Acti9 iC40N ARC Active proactively detects dangerous arcing conditions and trips before hazardous escalation. The integrated communication features support system-level monitoring and easier commissioning with EcoStruxure Power Commission or dedicated concentrators, enabling preventive maintenance and traceable diagnostics.
Typical applications
Use this device in modern homes, renovation projects, small commercial premises, and sub-distribution boards where enhanced fire prevention and remote diagnostics are desired. The product is especially useful where circuits feed sensitive loads or where occupant safety and compliance with stricter electrical codes are priorities.
Operation and maintenance
Installation and maintenance must be performed by qualified electricians. The product includes user prompts and LED codes for pairing, normal operation, communication issues, and specific tripping causes (parallel arc, series arc, overvoltage, internal fault). Routine self-tests using the Test button are recommended after installation and at regular intervals. Always isolate power before wiring or dielectric testing.
Final thoughts
Schneider Electric’s Acti9 iC40N ARC Active offers a compact, standards-compliant solution that merges arc-fault detection, overload/short-circuit protection, and communication in a single module. It enhances safety, facilitates diagnostics, and supports modern connected electrical systems while demanding proper professional handling and adherence to regulatory requirements.
Notes:
- Self-diagnostic tests must be run after installation and periodically.
- Disconnect all conductors before performing dielectric tests.
- Follow local regulations; do not attempt repairs—replace damaged units.