SAFETY AND NOTICES
Dear customers,
please completely read this instruction manual before the installation and commissioning. Observe all safety
instructions before you begin executing any work. Keep the instruction manual stored at hand and advise each user
about possible dangers that are related to this product. In case of a change in ownership pass on the instruction
manual to the new owner. In case of damages which are caused by misuse or improper installation the warranty and any
warranty claim will be void.
SAFETY INSTRUCTIONS
There is danger to life from electric shock!
Before working on electrical equipment, the facility must be de-energized. This also applies for the maintenance
and repair of the motorized awning system. Work on electrical installations may only be performed by licensed
electrical professionals. The provisions of the local electric utility company as well as all applicable standards and
regulations for electrical installations must be complied with.
Before working on roller shutter systems, the shutters must be secured against a self-actuated falling down.
Only use the tubular motor in dry rooms (protection class IP44).
The tubular motors become very hot during normal operation. Caution, risk of injury!
The connecting cable of the tubular motors may not be installed outdoors.
The tubular motor and the packaging are no toys. Keep children away from them. There is a danger of injury and su󰀨ocation.
During the adjustment process third parties must be kept away from the shutter system.
The tubular motors may not be opened.
The tubular motors are maintenance free and do not require any special care.
The cover of the shutter box should be installed in such a way, that an access is possible at any time.
Inspect the tubular motor prior to installation for damage and completeness of the accessories.
The tensile load and the dimensioning of the tubular motor must be adapted to the shutter system. The permitted load of the
tubular motor may not be exceeded.
The tubular motors are designed for short-term operation with a duty cycle of 4 minutes. In case of overheating due to long
operating times or a too high tensile load, the motor will stop. After a cooling period of at least 15 minutes, the tubular motor
will be ready for operation again.
Check the shutter system regularly for smooth running and for freezing in winter.
If you have technical questions about your shutter system, please contact our customer service.
During operation, small variations in the end-position can occur due to temperature di󰀨erences during the winter and sum-
mer. In case of need, a further ne tuning of the nal positions may be necessary.
Equalize length tolerances of the octagonal shaft with a suitable roller sleeve [item-no. 80100 (MINI),
item-no. 80200 (MAXI)].
The roller sleeve must be inserted at least 60 mm deep into the octagonal shaft (page 136). It may not touch the tubular
motor in the octagonal shaft or obstruct the motion.
The product must not be used or assembled by children or persons who are not in a position to use the product safely and
with caution due to physical, mental or sensory impairments. Children are not allowed to play with the product. The product
can be used by children of 8 years and above, as well as by persons with limited physical, sensory or mental capacities, or
those lacking in knowledge and experience, if they are supervised or have been instructed on the safe use of the product
and understand the hazards involved. Cleaning and user maintenance on the product must not be performed by children
without adult supervision.
INTENDED USE
The tubular motors are designed exclusively for use in roller shutter systems.
The tubular motors may only be used in properly assembled roller shutter systems.
The roller shutter systems must be in a awless condition.
Defects of the roller shutter systems must be resolved before the installation of tubular motors, and damaged parts must be
replaced.
Using the tubular motor for purposes other than those mentioned above is considered contrary to its designated use.
Alfred Schellenberg GmbH is not liable for personal, material or consequential damage in the case of improper use.

Chat with your Schellenberg RolloPower Standard 15Nm Maxi manual using AI

Get instant AI answers from your Schellenberg RolloPower Standard 15Nm Maxi manual

Ask anything about the Schellenberg RolloPower Standard 15Nm Maxi. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend RolloPower Standard 15Nm Maxi?

Yes No

Frequently Asked Questions

A

It is intended for use in roller shutter or blind systems where a tubular motor can be integrated. The MAXI configuration uses a 60 mm octagonal shaft, and the roller blind must be in proper working condition before motor installation.

Is this answer helpful?

A

After electrical connection, run the blind using the control commands in the direction required for checking and stopping. The motor stop behavior helps define the end region. If the upper end position does not stop as expected, pause it and correct the upper end manually using the corresponding adjustment screw.

Is this answer helpful?

A

No. The product must not be opened. It is described as maintenance-free and should not be disassembled. If settings or issues arise, follow the end-position adjustment steps intended for commissioning rather than attempting internal access.

Is this answer helpful?

A

The motor is designed for short-time operation with a maximum duty time of 4 minutes. If the motor overheats due to prolonged operation or excessive load, it switches off and becomes operational again after at least 15 minutes of cooling.

Is this answer helpful?

A

Use it only in dry indoor rooms. The protection rating is IP44, and the connection cable should not be routed outdoors.

Is this answer helpful?

A

Before any work on electrical installations, the system must be de-energized. Electrical installation and work should be performed only by approved electricians, following local energy provider rules and applicable electrical standards.

Is this answer helpful?

A

Yes, small deviations can occur due to temperature differences across seasons. If required, re-fine the end positions using the manual end-stop adjustment procedure to restore consistent travel.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Mechanical end-position setting helps you achieve accurate upper and lower travel.
  • Maxi 60 mm shaft system compatibility supports installation in suitable roller blind setups.
  • IP44 (dry indoor use) is suitable for typical indoor blind environments.
  • Clear stop behavior and defined fine-tuning steps support safer commissioning.
  • 3-year manufacturer warranty for covered material and manufacturing defects.
VS

Disadvantages

  • Short-time duty: 4 minutes maximum running time, then cooling time is required.
  • Warm operation under normal use means installation should allow appropriate conditions.
  • Electrical work must be done by approved electricians; DIY wiring is not recommended.
  • End-stop corrections may be needed due to seasonal position deviations.
  • The motor must only be used within specified load and blind-area limits.