17. The thermometer is a direct mode thermometer.
Reference site is oral and the measuring site is forehead.
CAUTION
1. Do not scrape or scratch the probe as it will hamper
the effectiveness of the device.
2. Do not dismantle the device except when replacing
the battery
3. Wait at least thirty minutes after exercising, bathing
or eating before taking a measurement.
4. If the subject’s body temperature is lower than the
room temperature, a false reading may occur.
5. To ensure the best performance of the device,
please follow the Product Specification “Storage
condition” regarding temperature and humidity
ranges for storing the device.
6. Dispose of the device and battery according to your
local regulatory or environmental protection agency.
7. The device is not intended for use in the emergency
medical services environment
For maximal performance of the device, we recommend a
regular checkup and device calibration every two years.
DEVICE DESSCRIPTION AND INTENDED USE
The thermometer is an electronic device intended to
measure the body (human) temperature. It is designed to
absorb the infrared from human body to detect your
temperature. It can be used with adult or pediatric
patients and it can be used in household.
ABOUT BODY TEMPERATURE
A person’s normal body temperature can range from
35.5°C to 37.8°C (95.9℉ to 100.0℉) throughout the day.
We recommend taking your temperature at different times
during the day when you are NOT sick. This will
GB-4
- Die Temperaturmessung eines Objektes
4. Wechseln Sie in den Modus Objekt-Messung (Siehe
Seite 10 Abschnitt "Messstelle wechseln").
5. Richten Sie die Messsonde
mit 3~8cm Abstand auf das
Objekt.
6. Betätigen Sie die Ein/Mess-Taste und lesen Sie das
Messergebnis auf der LCD-Anzeige ab.
REINIGUNG UND DESINFEKTION
1. Zur Reinigung und Desinfektion des Gerätes benutzen
Sie ein Baumwolltuch oder ein Pad angefeuchtet mit
70%igem Alkohol um den vorderen Teil des Gerätes
abzuwischen.
2. Um den Rest des Gerätes zu reinigen benutzen Sie ein
mit Wasser oder einem neutralem Waschmittel
angefeuchtetes Tuch. Danach trocknen Die das Gerät ab.
3. Verwenden Sie niemals Verdünner, Benzine oder
andere kräftige Reinigungsmittel.
4.Tauchen Sie das Gerät niemals in Wasser oder
andere Flüssigkeiten. Es ist nicht wasserdicht.
Reinigung:
1. Wischen Sie das Gerät mit einem sauberem Tuch ab.
2. Reinigen Sie das Gerät mit einer Lösung aus 5-10%
mildem Reinigungsmittel mit einem sauberen Tuch ca.
10-15 Minuten.
3. Setzen Sie den Reinigungsvorgang mit leicht
feuchtem Tuch fort, um auf dem Gerät verbliebenden
chemischen Rückstände zu vermeiden.
4. Verwenden Sie ein leicht feuchtes Tuch, um das Gerät
mit deionisiertem Wasser oder destilliertem Wasser
abzuwischen, um das Entfernen aller Reste des
Reinigungsmittels zu gewährleisten.
D-13

Chat with your Scala SC 8280 manual using AI

Get instant AI answers from your Scala SC 8280 manual

Ask anything about the Scala SC 8280. Answers come from this manual, with the pages they are based on.

SC 8280 Maintenance Schedule

Remind me when maintenance is due
Every 2 years
Perform device calibration checkup

To ensure maximal performance and accuracy, the manual recommends a regular checkup and device calibration every two years.

Show in the manual (page 13)
Before and after each use
Clean and disinfect the probe

Wipe the probe with 70% alcohol or mild detergent. Rinse with distilled water and air dry for 30-60 minutes before next use.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend SC 8280?

Yes No

Frequently Asked Questions

A

Press and hold the Memory button until the display shows the object icon. Press again for two seconds to switch back to forehead mode. The symbol will flash twice upon successful change.

Is this answer helpful?

A

Replace both AAA batteries simultaneously with new ones. Ensure correct polarity is followed. Note that replacing batteries may erase stored memory data.

Is this answer helpful?

A

Yes, the Scala SC8280 is safe for pediatric patients. However, always supervise children during use and avoid placing the probe on open wounds or scarred tissue.

Is this answer helpful?

A

The device has a clinical repeatability of less than +/- 0.3°C within the 34.0°C to 43.0°C range. It automatically converts forehead readings to oral equivalents using offset settings.

Is this answer helpful?

A

No, the unit is not waterproof. Do not immerse it in water or liquid. Clean only with a damp cloth and avoid harsh chemicals or submersion.

Is this answer helpful?

A

The device provides approximately 5,000 measurements on two AAA batteries, depending on usage frequency and environmental conditions.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Non-contact measurement prevents cross-contamination and ensures user comfort
  • Fast one-second measurement time provides instant results for active families
  • Dual functionality serves as both a human forehead and surface object thermometer
  • Long battery life supports over 5,000 measurements on standard AAA cells
  • Fever alarm system alerts users immediately when temperatures exceed 37.5°C
VS

Disadvantages

  • Device is not waterproof and must be kept away from liquids during cleaning
  • Accuracy can be affected if used on scarred tissue or skin exposed to extreme weather
  • Requires a specific distance of 3 to 8 cm for valid readings which may take practice
  • Memory storage resets if batteries are removed for extended periods
  • Not suitable for use near mobile phones or microwaves due to potential interference
M: QW-35-FL

Product Specification

Type

Infrared Thermometer

Operating Mode

Battery Powered (2x AAA Battery)

Application

On the Forehead

Measurement Units

°F

Measurement Range

32°F to 194°F (Surface Temperature)

Accuracy

±0.54°F

Measurement Time

1s

Memory Function

10 Memory Slots

Display

Yes

Features

Surface Measurement

M: QW-35-FL

Product Description

Discover the Precision of the Scala SC8280 Infrared Thermometer

The Scala SC8280 stands as a reliable companion for maintaining health within the comfort of your home. This advanced infrared forehead thermometer is designed to provide instant, non-contact temperature readings for both adults and children. Its sleek design ensures ease of use while delivering clinical accuracy that parents and caregivers can trust. The device utilizes sophisticated infrared technology to measure body heat from a safe distance, eliminating the discomfort associated with traditional probes.

Operating on two AAA batteries, the Scala SC8280 offers an impressive battery life capable of supporting at least 5,000 measurements. This longevity ensures that the device remains ready whenever you need it most. The unit features an automatic shut-off function after 60 seconds of inactivity, conserving power and extending the lifespan of the batteries. With dimensions of 138 x 90 x 45 mm and a lightweight build of 132 grams including batteries, it fits comfortably in any hand or medical kit.

One of the standout features of this model is its versatility. While primarily intended for measuring human forehead temperature, it also functions as an object thermometer. This dual capability allows users to check the temperature of liquids, baby bottles, or room surfaces by simply switching modes. The measuring range extends from 32.2°C to 43.3°C for humans and 0.0°C to 90.0°C for objects, covering all necessary scenarios. The high resolution of 0.1°C ensures precise data is displayed on the clear LCD screen.

Safety is paramount in the design of the Scala SC8280. It carries certifications under ISO 13485 and ISO 80601-2-56, reflecting its adherence to strict medical standards. The device includes a built-in fever alarm that triggers with audible beeps when a reading exceeds 37.5°C, providing immediate feedback. Additionally, the memory function stores up to 10 sets of previous readings, allowing users to track temperature trends over time. Proper cleaning and disinfection protocols are easy to follow, ensuring hygiene between uses without damaging the sensitive probe.

Important Notes

Always ensure the measuring site is dry and clean before use. Avoid measuring immediately after exposure to extreme temperatures or direct sunlight. For optimal performance, allow the device to acclimate to room temperature if stored in cold conditions.