Manual.ly Logo

Scala SC 28 flex Manual

0.0 · 0 Ratings

PDF manual · 16 Pages

English

M: qwen/qwen3.5-flash-20260224
page

/ 16

Loading...
2537799787e23c9f86bb838cc1f46736f006 page 5
Digital clinical thermometer SC 28 flex with
flexible measuring point and fever alarm
Special features
The SC 28 flex is a maximum thermometer, i.e. the highest temperature is displayed after only 10 seconds.
The most recent measured value is always saved. If the temperature registers higher than 37,5°C the fever
alarm will sound.
Safety information
• The SC 28 flex is suitable only for measuring human body temperatures.
• The thermometer contains small parts (batteries, etc) which could be swallowed by small children. Please
keep the thermometer and its batteries out of the reach of small children.
• Protect the SC 28 flex from direct sunshine and temperatures above 50°C.
• Never drop the SC 28 flex or open it (with the exception of the battery compartment for battery replacement).
Operating manual:
Press the I/O button to switch on. A short signal tone shows that the device is in the "switched on" condition. A
segment test takes place simultaneously (checks all display segments and carries out an internal function test
(see under "Function test")).
After this, if the temperature measured by the temperature sensor is less than 32°C, the display shows an "L“
and "°C“. After around one second, the "°C“ starts to blink. The „L“ stands for low (less than 32°C).
The current temperature is continuously displayed during measurement, and the "°C" blinks during the entire
measurement time. The measurement is completed after around 10 seconds.
After the measurement is completed, the temperature value measured remains in the display until the SC 28 flex
is switched off. To turn the device off after use, press the I/O button briefly. The signal tone will again be
sounded. If the device is not switched off, a signal tone is sounded after around 3 minutes and the device then
switches off automatically.
Fever alarm
If the temperature measured is 37.5°C or higher, a fever alarm is sounded (short double beeps for about 4
seconds). Four long beeps indicate that measurement is completed and the temperature is below 37.5°C.
Display of last measured value:
If you keep the I/O button pressed for longer than three seconds, the last measured value will be shown in the
display. As soon as you release the I/O button, the device is ready to take measurements.
Measured value deviation
The measured temperatures will always deviate, depending on the measurement location. This is normal, and
caused by deviations in temperature distribution on the human body. You could, for example, measure a rectal
temperature of 36.6°C, an oral temperature of 36.1°C and an underarm value of 35.6°C.
Measurement locations
In the mouth (oral)
Small temperature variations in the mouth between measurements are
normal. These are caused by varying temperature distribution within the
mouth. Try to place the thermometer in one of the two heat pockets under
the tongue, to the left and right of the tongue root. The measurement sensor
must have good contact with the
tissue. The subject should close the mouth and breathe normally through
the nose so that the measured result is not affected by breathed air.
Measuring period: approx. 10 seconds
In the anus (rectal)
This is the safest method. It is particularly suitable for infants and small children. Guide the thermometer point
carefully 2 - 3 cm into the anus. Measuring period: approx. 10 seconds
Under the arm (axillary)
From a medical viewpoint this type of measurement leads to inaccurate values. It is therefore unsuitable for
carrying out exact measurements.
Measuring the basal body temperature
The device can also be comfortably and practically used for the measurement of fertile or unfertile days in the
female cycle using the temperature measurement method.

Chat with your Scala SC 28 flex manual using AI

Get instant AI answers from your Scala SC 28 flex manual

Ask anything about the Scala SC 28 flex. Answers come from this manual, with the pages they are based on.

SC 28 flex Maintenance Schedule

Remind me when maintenance is due
Every 2 years
Perform metrological control for medical use

For devices used in medical practice, a measurement accuracy check is required every two years according to regulations. Contact customer service for details.

As needed
Replace the battery when low

Replace the battery with a new one of the same type (AG3/LR41/SR41) as soon as the low battery symbol appears on the display.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend SC 28 flex?

Yes No

Frequently Asked Questions

A

It measures from 32.0 to 43.9 degrees Celsius. Below 32 it shows low and above 43.9 it shows high error codes.

Is this answer helpful?

A

Approximately ten seconds for oral or rectal placement. Axillary measurement may require longer time to stabilize.

Is this answer helpful?

A

The device emits an acoustic alarm and the display blinks when temperature exceeds 37.5 degrees Celsius.

Is this answer helpful?

A

Yes, remove the cap and replace with LR41 or SR41 ensuring correct polarity is followed correctly.

Is this answer helpful?

A

Use alcohol pads to wipe the surface. For medical facilities, use Mucocit-F2000 or Helipur-Hplus for disinfection.

Is this answer helpful?

A

We provide a two-year guarantee from the date of purchase covering material or manufacturing errors only.

Is this answer helpful?

A

Yes, but do not let children swallow batteries. Use rectal method carefully for infants as per instructions.

Is this answer helpful?

M: qwen/qwen3.5-flash-20260224

Advantages and Disadvantages

Advantages

  • Measures temperature in ten seconds for faster results
  • Fever alarm triggers if temperature exceeds 37.5 degrees Celsius
  • Stores last measured value for easy review later
  • Two-year warranty covers manufacturing defects completely
  • Flexible tip simplifies oral and rectal measurements
VS

Disadvantages

  • Axillary measurements yield less accurate results medically
  • Small batteries pose swallowing hazards for young children
  • Auto-shutoff occurs after three minutes of inactivity
  • Specific battery types required may need special purchase
  • Accuracy changes outside 18 to 28 degree ambient range
M: qwen/qwen3.5-flash-20260224

Product Specification

Type

digital stick thermometer

Power Source

Battery (1x button cell)

Application

in mouth (oral), in armpit (axillary), in rectum (rectal)

Units

°F

Measurement Range

89.6°F to 111.02°F (Body temperature)

Accuracy

±0.18°F

Measurement Time

10s

Memory Function

Yes

Display

Yes

Features

Fever indicator, flexible tip, auto shutoff, waterproof

M: qwen/qwen3.5-flash-20260224

Product Description

Maintaining optimal family health often requires reliable tools for monitoring body temperature consistently every day. The Scala SC28 flex serves as an essential digital clinical thermometer designed for both home care and professional medical settings. Its primary appeal lies in speed and accuracy, providing a clear reading within ten seconds of contact with the patient. Users will immediately appreciate the automatic maximum reading capability, ensuring that the highest temperature reached is displayed immediately after the measurement process completes successfully. This feature is particularly useful when measuring fevers in children or adults who might remain uncooperative during the procedure or struggle to keep still. Safety is a significant concern with any electronic device used near vulnerable individuals. The detailed guidance emphasizes keeping the device and small batteries out of reach of small children due to risks associated with small parts or accidental ingestion. Furthermore, the instructions advise against exposing the unit to direct sunlight or extreme temperatures exceeding fifty degrees Celsius. The flexible measuring tip adds significant convenience for oral or rectal measurements, allowing easy adaptation to different user needs. The flexible measuring tip adds significant convenience for oral or rectal measurements, though users should note that axillary measurements may yield less accurate medical results compared to other methods used. The device includes a specific fever alarm function that triggers acoustically and optically when measured temperatures exceed thirty-seven point five degrees Celsius. This alerts caregivers instantly to potential health issues requiring immediate intervention. Power management is straightforward with the inclusion of a clear low battery symbol that warns users before failure occurs. Replacing the lithium batteries involves opening the compartment and swapping the specific LR41 or SR41 cells while respecting polarity orientation. The unit also stores the last measured value for convenience during subsequent checks and daily monitoring. Cleaning and disinfection are simple tasks using standard alcohol pads, making it suitable for hygiene-heavy environments where cross-contamination must be avoided. A two-year guarantee covers material defects, offering peace of mind regarding durability and manufacturer support for repairs or replacements easily. The device operates within a wide temperature range spanning from thirty-two degrees to forty-three point nine degrees Celsius. Anything outside these bounds triggers an error indication on the screen. An automatic shutoff occurs after three minutes of inactivity to conserve battery life. For accurate tracking, cleaning is recommended between uses, especially in shared households. The manufacturer recommends specific disinfectants for medical facilities to ensure hospital-grade sanitation standards. For those seeking detailed operational guidance, the Scala SC28 Flex White Manual provides comprehensive advice on error codes, proper disposal, and calibration checks. Proper maintenance ensures longevity and consistent performance over time for years of reliable use. Whether tracking basal temperatures or monitoring acute illness, this thermometer remains a dependable choice for accurate health data. Understanding measurement sites is vital for accurate readings. Always follow safety guidelines to avoid injury. Investing in quality health equipment supports better wellness outcomes and faster recovery times for your household during seasonal sickness periods.

M: qwen/qwen3.5-flash-20260224

© Copyright 2026 Manual.ly