Manual.ly Logo

Salicru Equinox2 T Manual

0.0 · 0 Ratings

PDF manual · 92 Pages

English

M: OA-GPT-5-NAN
page

/ 92

Loading...
29a2237b8c353c1d8521cc6712cb400b8d2a page 31
49
General Index
1. INTRODUCTION
1.1. THANK-YOU LETTER
2. SAFETY INFORMATION
2.1. USING THIS MANUAL
2.2. NOTES ON SAFETY.
2.3. CONVENTIONS AND SYMBOLS
2.3.1. Explanation of the symbols.
3. QUALITY ASSURANCE ANDSTANDARDS
3.1. MANAGEMENT STATEMENT
3.2. STANDARDS
3.3. ENVIRONMENT
4. PRODUCT DESCRIPTION.
4.1. BASIC FEATURES.
4.1.1. Function.
4.1.2. Models.
4.1.3. Applicable neutral points.
4.1.4. Storage conditions.
4.2. DIAGRAMS
4.2.1. 2 MPPT units (EQX2 4002-T .. EQX2 25002-T).
4.2.2. 4 MPPT units (EQX2 33004-T, EQX2 40004-T, EQX2 50004-
T and EQX2 60004-T).
4.2.3. 10 MPPT units (EQX2 100010-T).
4.3. SCREEN INTERFACE AND WIFI MODULE.
4.4. PACKING LIST.
5. INSTALLATION
5.1. LOCATION.
5.1.1. Installation location.
5.1.2. Recommended installation distances.
5.2. ASSEMBLY PROCESS.
5.2.1. 2 MPPT units (EQX2 4002-T .. EQX2 25002-T).
5.2.2. 4 MPPT units (EQX2 33004-T, EQX2 40004-T, EQX2 50004-
T and EQX2 60004-T) and 10 MPPT units (EQX2 110010-T).
5.3. ELECTRIC CONNECTION.
5.3.1. External earthing connection.
5.3.2. Solar field connection.
5.3.3. Connecting the AC outlet.
5.4. INSTALLATION OF THE MONITORING DEVICE.
5.4.1. Mechanical installation.
5.5. RS485 CONNECTION.
5.5.1. Description of the terminals.
5.5.2. Wiring steps.
5.6. GENERAL INSTALLATION DIAGRAM.
6. START-UP AND SHUTDOWN.
7. SYSTEM OPERATION.
7.1. SYSTEM FIRMWARE UPDATE.
7.2. DESCRIPTION OF THE SCREENS.
7.3. ON-LINE MONITORING OF THE INSTALLATION.
7.3.1. Download and register the "EQX-sun" app.
7.3.2. Configuration of the installation (plant) in the EQX-sun app.
7.3.3. "12h" Monitoring (Day).
7.3.4. "24h" monitoring. (Day and night).
7.3.5. Operation of the EQX-sun app.
7.3.6. Individual plant screen.
8. TROUBLESHOOTING GUIDE
8.1. ERROR MESSAGES.
8.2. TROUBLESHOOTING.
8.3. MAINTENANCE.
9. TECHNICAL FEATURES.
9.1. 2 MPPT UNITS.
9.2. 4 AND 10 MPPT UNITS.
10. ANNEX. WIFI MODULE SETUP.
EN
EQX2 SOLAR INVERTERS CONNECTED TO THE GRIDUSER MANUAL

Chat with your Salicru Equinox2 T manual using AI

Get instant AI answers from your Salicru Equinox2 T manual

Ask anything about the Salicru Equinox2 T. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend Equinox2 T?

Yes No

Frequently Asked Questions

A

Select a model based on total PV array power, required MPPT count and site layout. Small residential systems suit 4–10 kW 2-MPPT units; larger commercial or industrial arrays require 4- or 10-MPPT models up to 110 kW. Verify DC voltage and current limits in the technical specs.

Is this answer helpful?

A

Yes. The series has an IP65-rated enclosure for indoor and outdoor use, but installation location should protect the unit from direct intense sunlight, ensure good ventilation, support its weight, and meet recommended clearance distances for cooling and safety.

Is this answer helpful?

A

Install the optional WiFi/RS485 dongle and register the inverter on the EQX-sun app. Follow the WiFi module setup steps (connect to inverter SSID, configure router SSID/password, restart) or use 24h monitoring accessories for night-time consumption tracking.

Is this answer helpful?

A

Built-in protections include DC polarity reversal, DC switch, isolation monitoring, residual current detection, over/under voltage, overtemperature, anti-islanding, and AC short-circuit and overcurrent protections. Additional DC/AC external protective devices are recommended per model.

Is this answer helpful?

A

Yes. The inverter will function and display local generation data on the OLED screen without internet. Remote monitoring and cloud features require WiFi/485 connectivity and the EQX-sun platform.

Is this answer helpful?

A

Periodic visual inspections and cleaning every 6–12 months (depending on dust) are advised. Before any service, disconnect AC and DC, wait for internal capacitors to discharge (≥5 minutes), and only allow qualified personnel to perform internal repairs to avoid voiding warranty.

Is this answer helpful?

A

Common issues include lost grid detection, over/under voltage, insulation faults or high DC injection. Initial steps: verify AC mains and protective devices, check DC switch and PV string voltages/polarity, inspect grounding and CT orientation, and consult error-table troubleshooting; contact Salicru support if persistent.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Wide power range (4 kW to 110 kW) with 2/4/10 MPPT options for flexible system designs.
  • High efficiencies (~98% peak, high MPPT accuracy) minimize energy losses.
  • IP65-rated enclosure suitable for indoor/outdoor installations with robust protections integrated.
  • OLED display plus WiFi/RS485 communications and EQX-sun app for local and remote monitoring.
  • Comprehensive safety, standards compliance and detailed installation/troubleshooting guidance.
VS

Disadvantages

  • Requires qualified installer and careful adherence to grounding and protection rules to avoid hazards.
  • WiFi/monitoring features depend on optional dongles or network availability for 24h data.
  • Large models are heavy and need adequate mounting support and space for ventilation.
  • Some configurations (string voltages, MPPT limits) demand precise design to avoid overvoltage.
  • Firmware, regional grid code settings and app setup add commissioning complexity for non-experts.
M: OA-GPT-5-NAN

Product Specification

Note

Prices partly include 0% VAT tax rates for AT and DE

Type

Solar inverter, without transformer, passive

Input voltage

160-1100V Direct current (DC)

Number of MPP trackers

2

Output phases

3-phase

Efficiency

98.1% max., 97.9% ηEU

Input

MC4

Output

Terminals

Interfaces

Wi-Fi (WLAN), 1x RS-485

Noise level

<25dB

Degree of protection

IP65

Ambient temperature

-22°F to +140°F

Dimensions

21.65x16.14x6.89in (WxHxD)

M: OA-GPT-54-NAN

Product Description

Salicru EQUINOX2 T — Reliable Three-Phase Grid-Tied Solar Inverter

The Salicru EQUINOX2 T series is a family of three-phase grid-tied solar inverters designed for residential, commercial and industrial PV installations. Models range from smaller 4 kW units up to large 110 kW systems, offering flexible MPPT configurations (2, 4 and 10 MPPT variants) to accommodate diverse array layouts and orientations. Built for high efficiency and robust grid compliance, the EQUINOX2 T converts DC from PV strings to AC for grid injection while providing monitoring, safety protections and optional 24-hour telemetry.

Key product highlights

The series supports multiple neutral regimes (TN-S, TN-C, TN-C-S, TT, IT), wide MPPT voltage ranges and high maximum DC voltages. Units are IP65 rated for indoor or outdoor mounting, include integrated protections (DC switch, anti-islanding, residual current, over/under voltage/temperature), and offer OLED displays with WiFi/RS485 communication for local and remote monitoring via the EQX-sun app. Models differ by MPPT count and power capacity, enabling tailored designs for single-field or multi-field installations.

Performance and usability

EQUINOX2 T inverters deliver high peak and European efficiencies (up to ~98%+), very low night consumption (<1 W), and fast MPPT response. They include configurable settings (grid standards, power limits, phase/CT ratios), clear menu navigation on the display, and step-by-step commissioning guidance. The optional WiFi/485 modules and EQX-sun platform support live monitoring, historical analysis, energy savings estimates and plant management across multiple installations.

Safety, installation and maintenance

The product emphasizes installer safety and compliance: certified to many international standards (IEC, EN, UNE, VDE, RoHS, WEEE), with detailed wiring, grounding and protection requirements. Installation guidance covers location, mounting clearances, DC/AC connector assembly, CT orientation, and earthing best practices. Troubleshooting and error codes are documented, and maintenance recommendations include periodic cleaning and component checks.

Notes

  • Choose the appropriate model based on PV array size, required MPPT count and local grid connection rules.
  • Ensure qualified personnel perform installation and commissioning; follow local regulations and use recommended protective devices.
  • Optional monitoring accessories (24h WiFi/485 and energy sensors) enable full-day consumption tracking.
M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly