25G Universalmodul
25G Universal Module
Montageanleitung | Installation instructions
Installation
In order to prevent malfunctioning, only use patch cables that
have been tested according to ISO/IEC 61935-2 with connectors
that are conform with ISO/IEC 60603-7-81.
Preparing the cable
1 Remove the cable sheathing along a total length of
minimum 60 mm (see figure 1).
2 Shorten the braided shield (A) to approx. 10 mm and pull
it backwards over the cable sheathing.
3 Shorten the shielding foils to 6 mm each.
4 Shorten the individual wire pairs (B) of different lengths
for easier threading into the wire distributor.
Cable installation
5 Insert the wire pairs (F) with descending length from
behind into the wire distributor (D) and position the
wires according to the desired colour assignment (see
figure 3).
6 Fix the cable by tightening the cable tie, shorten the
projection of the cable tie (see figure 3).
7 Pull the respective wire pairs firmly into the colour-coded
wire fixings (G) by hand so that the wire sheath sits in the
wire distributor ‘to the stop’.
8 Now use a cutting tool to shorten the protruding wire
ends so that all wires are flush with the block of the
wire distributor (see Figure 4).
9 Insert the wire distributor (twist-proof) from behind into
the module head (E).
10 Press the wire distributor and the module head – as
shown in figure 6 – together with a parallel lifting clamp
with a span of 40 mm (H).
11 If necessary, connect a potential equalization (I) – as
shown in figure 7 – to the contact tongue (J, flat connec-
tor 6.3 mm)..
Dismantling
12 To remove the cable from the module head generally
proceed in reverse order.
13 Unlock the rear cover as shown using a suitable screw-
driver (K) and pull it out of the housing including the wire
distributor.
Montage
Verwenden Sie ausschließlich geprüfte Patchkabel gemäß
ISO / IEC 61935-2 mit Steckern gemäß ISO / IEC 60603-7-81
um Fehlfunktionen zu vermeiden!
Kabelvorbereitung
1 Entfernen Sie den Kabelmantel auf einer Länge von
mindestens 60 mm (siehe Abbildung 1).
2 Kürzen Sie den Geflechtschirm (A) auf ca. 10 mm und
ziehen diesen nach hinten umlaufend über den Kabel-
mantel.
3 Kürzen Sie die Schirmfolien auf jeweils 6 mm.
4 Kürzen Sie die einzelnen Adernpaare (B) unterschiedlich
lang zum vereinfachten Einfädeln in den Adernverteiler.
Kabelmontage
5 Führen Sie die Adernpaare (F) mit absteigender Länge
von hinten in den Adernverteiler (D) ein und positionieren
Sie die Adern passend zur gewünschten Farbbelegung
(siehe Abbildung 3).
6 Fixieren Sie das Kabel durch Anziehen des Kabelbin-
ders, kürzen Sie den Überstand des Kabelbinders
(siehe Abbildung 3).
7 Ziehen Sie die jeweiligen Adernpaare in die farbig mar-
kierten Adernfixierungen (G) mit der Hand fest hinein, so
dass der Adernmantel bis ‚zum Anschlag‘ im Adernver-
teiler sitzt.
8 Kürzen Sie jetzt mit einem Schneidewerkzeug die über-
stehenden Aderenden so, dass alle Adern bündig
mit dem Block des Adernverteilers abschließen (siehe
Ab bildung 4).
9 Führen Sie den Adernverteiler (verdrehsicher) von hinten
in den Modulkopf (E) ein.
10 Drücken Sie den Adernverteiler und den Modulkopf
– wie in Abbildung 6 gezeigt – mit einer Parallelhubzange
(H) mit einer Spannweite von 40 mm (SW40) zusammen.
11 Bei Bedarf stecken Sie einen Potentialausgleich (I)
– wie in Abbildung 7 dargestellt – auf die Kontaktzunge
(J, Flachsteckverbinder 6,3 mm).
Demontage
12 Gehen Sie zur Entnahme des Kabels aus dem Modul-
kopf generell in umgekehrter Reihenfolge vor.
13 Entrasten Sie den rückseitigen Deckel wie gezeigt mittels
eines geeigneten Schraubendrehers (K) und ziehen Sie
ihn inklusive Adernverteiler aus dem Gehäuse heraus.
Technical Support
+49 2355 82-111
Commercial Support
+49 2355 82-137
4
6
7
I J
min. 60 mm10
6
* Folie / foil
1
A B
3
A
2
E
C
D
G
H
5
F
8
K

Chat with your Rutenbeck UM-Cat.6A iso 25/10G manual using AI

Get instant AI answers from your Rutenbeck UM-Cat.6A iso 25/10G manual

Ask anything about the Rutenbeck UM-Cat.6A iso 25/10G. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend UM-Cat.6A iso 25/10G?

Yes No

Frequently Asked Questions

A

This module is designed to handle both 10 Gigabit and 25 Gigabit Ethernet speeds, making it suitable for high-performance networks requiring fast data transfer rates.

Is this answer helpful?

A

Yes, the module meets IEEE 802.2at standards for PoE+, allowing it to power connected devices like access points or cameras without additional power supplies.

Is this answer helpful?

A

The module is built for longevity with a service life of at least 750 mating cycles, ensuring reliable performance even in frequently changed connection scenarios.

Is this answer helpful?

A

To ensure proper operation, only use patch cables tested according to ISO/IEC 61935-2 with connectors that conform to ISO/IEC 60603-7-81 standards.

Is this answer helpful?

A

No, installation requires a parallel lifting clamp with a 40 mm span to press the wire distributor and module head together securely.

Is this answer helpful?

A

Yes, the module is halogen-free, which reduces toxic smoke emission during combustion, enhancing safety in enclosed environments.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Supports both 10G and 25G transmission speeds for versatile networking needs
  • High durability with over 750 mating cycles and solid conductor build
  • Excellent shielding protects against interference and ensures signal clarity
  • Halogen-free material enhances safety during fire incidents
  • Compatible with PoE+ standards for powering network devices directly
VS

Disadvantages

  • Requires specific installation tools like a 40 mm parallel lifting clamp
  • Strict adherence to cable preparation steps is necessary for proper function
  • Limited ambient temperature range compared to some industrial-grade alternatives
  • Potential equalization connection adds complexity for simple setups
  • Higher cost compared to unshielded Cat.6 modules due to advanced shielding
M: QW-35-FL

Product Specification

Type

Keystone module (1x RJ-45, Cat6a, via RJ-45 jack)

Features

fully shielded

M: QW-35-FL

Product Description

Rutenbeck UM-Cat.6A iso 25/10G Universal Module Overview

The Rutenbeck UM-Cat.6A iso 25/10G Universal Module represents a significant leap in structured cabling infrastructure, designed specifically for high-speed data transmission environments. This shielded module is engineered to support both 10 Gigabit and 25 Gigabit networks, making it an ideal choice for modern data centers and enterprise facilities that demand robust performance and future-proof connectivity.

Constructed with precision, this universal module adheres to strict ISO/IEC standards, ensuring compatibility with tested patch cables featuring connectors conforming to ISO/IEC 60603-7-81. The design emphasizes reliability through its shielding capabilities, which protect against electromagnetic interference while maintaining signal integrity over long distances. The module features a solid conductor construction with AWG 22/1-23/1 wire specifications, providing durability and consistent electrical performance across mating cycles exceeding 750 connections.

Installation is straightforward when following the provided guidelines. Users must strip the cable sheathing by at least 60 mm and carefully manage the braided shield and foil layers. The process involves threading individual wire pairs into a color-coded wire distributor, securing them firmly, and then pressing the components together using a parallel lifting clamp with a 40 mm span. For optimal performance, potential equalization can be connected to the contact tongue if required. The unit operates within a wide temperature range from -40 to +85 degrees Celsius and supports PoE+ applications according to IEEE 802.2at standards.

Key Features

This module is halogen-free, contributing to safer fire conditions in enclosed spaces. It offers excellent dielectric strength with 1,000 V between contacts and 1,500 V between contacts and housing. The insulation resistance remains above 500 MΩ, ensuring minimal signal leakage. With low contact resistance of just 20 mΩ for signal contacts, data transfer remains efficient and fast.

Important Notes

Always use only patch cables tested according to ISO/IEC 61935-2 to prevent malfunctioning. Ensure all wire ends are flush with the wire distributor block before final assembly. Use a suitable screwdriver for dismantling the rear cover to avoid damaging the housing.

Pros and Cons

Pros

  • Supports both 10G and 25G transmission speeds for versatile networking needs.
  • High durability with over 750 mating cycles and solid conductor build.
  • Excellent shielding protects against interference and ensures signal clarity.
  • Halogen-free material enhances safety during fire incidents.
  • Compatible with PoE+ standards for powering network devices directly.

Cons

  • Requires specific installation tools like a 40 mm parallel lifting clamp.
  • Strict adherence to cable preparation steps is necessary for proper function.
  • Limited ambient temperature range compared to some industrial-grade alternatives.
  • Potential equalization connection adds complexity for simple setups.
  • Higher cost compared to unshielded Cat.6 modules due to advanced shielding.
M: QW-35-FL

© Copyright 2026 Manual.ly