1. GENERAL
• Please read the instructions before putting the product into operation, keep them for future
reference, and hand them over to the new owner if the product changes hands.
• The ground spike is splash-proof (IP44) and suitable for use outdoors.
2. SAFETY INSTRUCTIONS
• Do not operate or use any damaged product.
• Check the product regularly for damage. Do not continue to use the product in case of
defects.
• Only connect the product to a grounded earthed socket.
• Do not carry out any repairs to the product.
• Do not use this product in troughs or depressions as this may cause waterlogging and the
risk of flooding.
• Make sure that the product has a safe stand when operated.
• Do not operate the product in water.
• The product is splash-proof (IP44) and can be used outdoors.
• The splash guard is only guaranteed if connectors of the same degree of protection (IP44)
are connected and completely plugged in.
• Do not operate the product when it is covered.
• Do not operate the product when it is covered.
• The device is voltage-free only when the mains plug has been pulled out.
• Only connect devices that are suitable for unattended operation.
• Observe the maximum output of the product (see technical data and rating plate).
3. MOUNTING
1. Screw the foot (spike or mounting plate) clockwise to the sleeve.
2. Then screw the sleeve clockwise into the socket body.
3. Mounting
3.1 Installation with ground spike (picture A)
Insert the spike of the product into a solid surface, maximally up to plate and ensure
adequate stability. Also pay attention to a vertical position when inserting and operating
the product.
3.2 Mounting with mounting plate(picture B)
Mount the mounting plate with four screws (Ø 5mm) and corresponding dowels on
firm ground (e.g. base plate). Ensure adequate stability. Also pay attention to a vertical
position when operating the product.
4. Insert the plug of the product into a grounded earthed socket of the same degree of
protection (IP44).
5. The product is now ready for use.
ANL_G01102.2_G01104.2.indd 4 11.02.2019 09:33:16

Chat with your REV Ritter Garden Socket manual using AI

Get instant AI answers from your REV Ritter Garden Socket manual

Ask anything about the REV Ritter Garden Socket. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend Garden Socket?

Yes No

Frequently Asked Questions

A

It can supply compatible 230 V devices with a combined load of up to 3500 W at 16 A. Typical uses include outdoor lighting, pumps, and garden equipment. Check each device rating and do not exceed the total load limit.

Is this answer helpful?

A

It has IP44 splash protection, making it suitable for outdoor use. It is not designed for immersion or standing water. Protection is maintained only when IP44-rated plugs are fully inserted.

Is this answer helpful?

A

Screw the ground spike to the sleeve, connect the sleeve to the socket body, then push the spike into firm ground up to the support plate. Keep the unit upright and make sure it has a secure, stable position.

Is this answer helpful?

A

Yes. It can be used with a mounting plate instead of the ground spike. Fix the plate to a firm base using four 5 mm screws and suitable wall plugs, while ensuring the socket remains vertical and stable.

Is this answer helpful?

A

Do not place it in dips, troughs, or other areas where water may collect. Do not operate it in water, cover it during use, or connect it in series with another socket unit.

Is this answer helpful?

A

First disconnect the mains plug from the grounded outlet. Clean the unit only with a dry, lint-free cloth. Do not use abrasive products, corrosive chemicals, or liquids.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Two grounded outlets provide convenient power for compatible garden equipment and lighting.
  • Ground spike enables quick positioning in firm soil without permanent installation.
  • Optional mounting plate supports a more fixed installation on a solid base.
  • IP44 splash protection supports outdoor use when matching IP44 plugs are fully connected.
  • 1.4 m H07RN-F cable and 3500 W maximum load suit many everyday outdoor power needs.
VS

Disadvantages

  • Not waterproof and must never be used in water or flood-prone depressions.
  • IP44 protection depends on using fully inserted plugs with the same IP44 rating.
  • The 1.4 m cable may require an additional suitable extension for distant power sources.
  • Only two outlets are available, which may not suit larger multi-device setups.
  • Operation is limited to temperatures from -10 C to 25 C.
M: gpt-5.6-terra

Product Specification

Outlets

2 x Schuko

Input voltage

230 V

Power

3,500 W (max.)

Additional ports

N/A

Material

Plastic

Cable length

4.59 ft

Dimensions (W x H x D)

13.11 x 4.46 x 2.54 in

Weight

1.15 lb

Features

IP44-certified, self-closing covers

M: gpt-5.6-terra

Product Description

REV Ritter Garden Socket with Ground Spike, 2-way, 1.4m - Read, Download & Print Free

The REV Ritter Garden Socket with Ground Spike, 2-way, 1.4m is a practical outdoor power solution for bringing electricity closer to where it is needed. Designed for gardens, patios, driveways, and other outdoor areas, it provides two grounded outlets in a compact, stable unit. Whether powering garden lighting, a pond pump, seasonal decorations, or suitable outdoor tools, this socket helps reduce the need for long extension leads running across the property.

Flexible positioning outdoors

A key feature is the ground spike mounting system. The spike can be inserted into firm soil up to its support plate, allowing the socket to stand vertically and securely in a convenient location. For more permanent setups, the socket body can also be fitted to a mounting plate, which is secured to a solid base with four suitable screws and wall plugs. This flexibility makes the unit useful for both temporary garden projects and fixed outdoor power points.

The integrated 1.4 m H07RN-F 3G1.5 mm2 cable provides a durable connection lead for outdoor-oriented installations. The unit operates at 230 V, 50 Hz and supports a maximum load of 3500 W at 16 A. Users should always add up the power requirements of connected devices and stay within this limit.

Splash protection and safe use

With an IP44 rating, the garden socket is protected against splashing water and is intended for outdoor as well as indoor use. For the splash protection to remain effective, connected plugs must also be IP44 rated and fully inserted. The socket should be connected only to a properly grounded outlet with the same protection rating.

Careful placement is important. Avoid hollows, dips, and places where water can collect, as standing water can create a flooding risk. The unit must not be used in water, covered during operation, or connected in series with other socket units. Regular checks for damage to the housing, cable, and plugs support safer operation. Disconnect it from the mains before cleaning, and use only a dry, lint-free cloth.

A tidy power point for garden tasks

The two-way design offers a straightforward way to run two compatible devices from one outdoor location. It is especially useful when lighting and a low-power accessory need power in the same area. Select devices suitable for unattended operation when they will be left connected, and ensure that all outdoor electrical circuits are appropriately protected.

Notes

  • Install the ground spike only in firm ground and keep the socket upright.
  • Do not exceed 3500 W total connected load.
  • Dispose of the product through designated electrical equipment collection systems when it reaches end of life.