Online USV Xanto X10000 Manual
PDF manual · 58 Pages
English

Quick check
Incorrect answer, please try again.
Chat with your Online USV Xanto X10000 manual using AI
Get instant AI answers from your Online USV Xanto X10000 manual
Ask anything about the Online USV Xanto X10000. Answers come from this manual, with the pages they are based on.
Xanto X10000 Maintenance Schedule
If storing the UPS system for an extended period, charge the battery every three months by connecting the UPS to utility power for five hours.
Replace batteries when BR is shown on the display and an alarm sounds every 2 seconds.
Free maintenance reminders
Timed to your purchase date. Always free, unsubscribe anytime.
Ask a Question
Do you recommend Xanto X10000?
Yes NoFrequently Asked Questions
The Xanto X10000 uses true double-conversion (VFI-SS-111) topology, supplying a continuous pure sinewave output to protected loads and isolating them from input disturbances.
Is this answer helpful?
Yes. The X10000 supports external battery packs. You must physically connect the packs, enable the correct number in the UPS menu, and allow proper charging; runtime scales with the number of packs installed.
Is this answer helpful?
Yes. The unit supports USB or RS-232 connections and a slot for SNMP or relay (AS400/dry-contact) cards. DataWatch software enables automated shutdown, logging and network management.
Is this answer helpful?
Yes. Up to three identical units can be paralleled for increased power or configured n+1 for redundancy. All units must have identical menu settings, matching battery configurations, and proper parallel/sync cabling.
Is this answer helpful?
Install only in controlled temperature/humidity environments, connect earth first, have a qualified electrician perform mains wiring, and follow battery handling precautions. Ensure ventilation and observe cable cross-sections and fuse recommendations.
Is this answer helpful?
In battery mode, press and hold the mute/button for 2 seconds to silence the audible alarm. Check the display for warning codes and follow troubleshooting steps; replace batteries when the display shows BR or persistent battery faults.
Is this answer helpful?
Yes. The UPS can operate in frequency converter mode to provide a fixed 50 Hz or 60 Hz output; in this mode bypass is not available and the setting must be enabled in the configuration menu.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- True double-conversion topology with pure sinewave output for maximum load protection.
- High efficiency (up to ~98% in ECO mode) reduces energy costs and heat.
- Scalable autonomy with external battery packs and configurable battery deep-discharge protection.
- Parallel operation and redundancy support (up to 3 units) for increased capacity or n+1 availability.
- Multiple communication options: USB, RS-232, SNMP or relay cards, plus DataWatch software for automated shutdowns.
Disadvantages
- Large and heavy—requires careful handling and rack space; additional battery packs add significant weight.
- Some advanced features (e.g., switchable sockets) not available on all models (not on X6000/X10000 base).
- RS-232 and USB cannot be used simultaneously; extra cards required for full network management.
- Parallel installation requires precise cable lengths and identical configuration across units.
- Serviceable batteries are not hot-swappable across all models; battery replacement may need downtime.
Product Specification
Type
Tower/Rackmount
Classification
VFI-SS-111 (On-Line)
Apparent Power
10,000VA
Active Power
8,000W
Voltage
230V
Input
Dry Contact
Outputs
Dry Contact
Interfaces
USB, serial
Data Line Protection
1x RJ-11, 1x RJ-45
Weight
44.09 lb
Dimensions (WxHxD)
17.24x3.46x24.02in
Height Units
2U
Special Features
LCD
Manufacturer's Warranty
two years
Product Description
Online UPS Xanto X10000 10000VA, USB/serial Manual
The Online UPS Xanto X10000 is a robust, true double-conversion (VFI-SS-111) uninterruptible power supply designed to protect servers, network equipment and sensitive electronics. Delivering 10000VA / 10000W (power factor 1.0 for tower/rack models), the unit produces a pure sinewave output, supports USB and RS-232 communications, and offers options for SNMP or relay cards for integration into monitoring systems. Its tower/rack-versatile design (4 HU) and scalable battery autonomy via external battery packs make it suitable for data closets, small server rooms and edge deployments where clean, continuous power is essential.
The Xanto X10000 supports parallel operation for increased capacity and redundancy, plus a dedicated emergency power off (EPO) input and optional switchable output groups (on larger models) to prioritize critical loads. It features automatic/manual bypass, cold-start capability, battery deep-discharge protection, and an efficiency profile up to ~98% in high-efficiency mode. The unit includes a graphical display and front-panel controls for status, menus and measurements (input/output voltages, battery status, load, autonomy time). Built-in diagnostics, audible alarms with muting, and an extensive configuration menu let administrators tailor behavior for bypass, battery cutoff, frequency conversion (50/60 Hz), and fine voltage adjustments.
Installation supports tower or 19" rack mounting (with optional rails) and uses robust terminal connections for input/output and battery links. The UPS accepts additional battery packs to extend runtime; the number of installed packs is set in the configuration menu. For parallel groups, synchronization and parallel cables must be used and menu settings aligned across units. The bundled DataWatch software (or downloadable updates) enables automated, orderly shutdowns, event logging, data capture, and networked management; RS-232 or USB links are provided (not simultaneously active), and SNMP/professional adapter options are supported.
On maintenance, the Xanto series recommends periodic battery checks and replacement when the display indicates replacement or faults. Safety guidance stresses qualified installation, earth-first connections, careful handling of heavy battery packs, and proper battery disposal. The product ships with a warranty and options for advance-replacement support from the manufacturer.
Notes:
- True double-conversion UPS with pure sinewave output ensures continuous, clean power without transfer disturbance.
- Scalable runtime through external battery packs; configure number of packs in the menu.
- Supports parallel/redundant operation (up to three units) for power growth or n+1 redundancy.
Search for 67,706 Manuals online